Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted

Objetivou-se com o presente estudo comparar um kit comercial de ELISA para a detecção de coproantígenos e um exame coproparasitológico de sedimentação utilizando-se como padrão ouro o diagnóstico da inspeção de fígados bovinos ao abate. Além disso, avaliou-se a correlação entre a intensidade parasit...

Full description

Bibliographic Details
Main Authors: Cíntia das Chagas Bernardo, Barbara Rauta de Avelar, Mariana Drummond Costa Ignacchiti, Isabella Vilhena Freire Martins, Maria Julia Salim Pereira
Format: Article
Language:English
Published: Universidade Federal de Santa Maria 2012-11-01
Series:Ciência Rural
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782012001100018
id doaj-3a01966a18794cf683b81a033f7710be
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Cíntia das Chagas Bernardo
Barbara Rauta de Avelar
Mariana Drummond Costa Ignacchiti
Isabella Vilhena Freire Martins
Maria Julia Salim Pereira
spellingShingle Cíntia das Chagas Bernardo
Barbara Rauta de Avelar
Mariana Drummond Costa Ignacchiti
Isabella Vilhena Freire Martins
Maria Julia Salim Pereira
Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
Ciência Rural
Fasciola hepatica
bovino
imunodiagnóstico
Fasciola hepatica
bovine
immunodiagnosis
author_facet Cíntia das Chagas Bernardo
Barbara Rauta de Avelar
Mariana Drummond Costa Ignacchiti
Isabella Vilhena Freire Martins
Maria Julia Salim Pereira
author_sort Cíntia das Chagas Bernardo
title Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
title_short Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
title_full Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
title_fullStr Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
title_full_unstemmed Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
title_sort kit comercial de elisa® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose commercial elisa® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convicted
publisher Universidade Federal de Santa Maria
series Ciência Rural
issn 0103-8478
1678-4596
publishDate 2012-11-01
description Objetivou-se com o presente estudo comparar um kit comercial de ELISA para a detecção de coproantígenos e um exame coproparasitológico de sedimentação utilizando-se como padrão ouro o diagnóstico da inspeção de fígados bovinos ao abate. Além disso, avaliou-se a correlação entre a intensidade parasitária mensurada pela contagem de ovos nas fezes e a de parasitos ao abate. Foram coletadas as fezes e avaliados macroscopicamente os fígados de 81 bovinos, dos quais 45 tiveram os fígados condenados por fasciolose hepática ao abate, nos quais se realizou a contagem dos parasitos. Duas frações de cada amostra de fezes coletadas foram separadas e uma delas foi armazenada em congelador para posterior realização do ELISA e a outra processada segundo uma técnica de sedimentação fecal para diagnóstico de ovos de Fasciola hepatica. O coeficiente de correlação de Spearman e o qui-quadrado de McNemar foram utilizados, adotando-se o nível de significância de 5%. Em oito fígados bovinos condenados por apresentarem lesões características de fasciolose, não foram encontrados exemplares do parasito. O exame coproparasitológico e o ELISA para detecção de coproantígenos, respectivamente, apresentaram sensibilidade de 51,11% e 75,55%, especificidade de 100% e 91,66%, valor preditivivo positivo de 100% e 91,89%, valor preditivo negativo de 62% e 75% e kappa de 0,48 e 0,65. Os resultados obtidos pelo kit ELISA comercial não diferiram (P=0,06) dos obtidos ao abate, mas o exame coproparasitológico diferiu (P<0,0001) do abate na detecção de animais positivos. A correlação entre o número de parasitos no fígado e o número de ovos nas fezes é moderada (rs=0,5757, P<0,0001). O kit ELISA comercial foi mais sensível do que o exame coproparasitológico, embora este não deva ser descartado devido a sua eficiência.<br>The aim of this study was to compare a commercial ELISA kit for detection on coproantigen examination and fecal sedimentation using as gold standard inspection diagnosis of bovine livers at slaughter. In addition, we evaluated the correlation between the measured intensity of infection by counting eggs in the feces and the parasites in bovine livers. Feces were collected and evaluated macroscopically of 81 cattle livers, 45 of which had livers condemned by liver flukes and in these livers parasites were counted. Two fractions of stool samples collected were separated and one stored in freezer for further ELISA and other one processed according to sedimentation technique for diagnosis Fasciola hepatica. The Spearman correlation and McNemar chi-square were used, adopting the significance of 5%. In eight bovine livers condemned by the characteristic lesions of fascioliasis parasite were not found. The stool examinations and ELISA testing for detection coproantigen, respectively, had sensitivity of 51.11% and 75.55%, specificity of 100% and 91,66%, predictive positive value was 100% and 91.89%, predictive negative value 62% and 75% and kappa 0.48 and 0.65. The results obtained by commercial® ELISA kit did not differ (P=0,06) obtained at slaughterhouse, but the stool examinations differed (P<0.0001) in the detection of the positive animals. The correlation between the number of parasites in the liver and the number of eggs in the feces was moderate (rs=0.5757, P<0.0001). The commercial ELISA kit® was more sensitive than the fecal test, althought this one shoud not be discarded because of their efficiency.
topic Fasciola hepatica
bovino
imunodiagnóstico
Fasciola hepatica
bovine
immunodiagnosis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782012001100018
work_keys_str_mv AT cintiadaschagasbernardo kitcomercialdeelisaparaadeteccaodecoproantigenoseexamecoproparasitologicoembovinoscomfigadoscondenadosporfasciolosecommercialelisakitfordetectionofcoproantigenandcoproparasitologicalmethodinbovineliverswithfascioliasisconvicted
AT barbararautadeavelar kitcomercialdeelisaparaadeteccaodecoproantigenoseexamecoproparasitologicoembovinoscomfigadoscondenadosporfasciolosecommercialelisakitfordetectionofcoproantigenandcoproparasitologicalmethodinbovineliverswithfascioliasisconvicted
AT marianadrummondcostaignacchiti kitcomercialdeelisaparaadeteccaodecoproantigenoseexamecoproparasitologicoembovinoscomfigadoscondenadosporfasciolosecommercialelisakitfordetectionofcoproantigenandcoproparasitologicalmethodinbovineliverswithfascioliasisconvicted
AT isabellavilhenafreiremartins kitcomercialdeelisaparaadeteccaodecoproantigenoseexamecoproparasitologicoembovinoscomfigadoscondenadosporfasciolosecommercialelisakitfordetectionofcoproantigenandcoproparasitologicalmethodinbovineliverswithfascioliasisconvicted
AT mariajuliasalimpereira kitcomercialdeelisaparaadeteccaodecoproantigenoseexamecoproparasitologicoembovinoscomfigadoscondenadosporfasciolosecommercialelisakitfordetectionofcoproantigenandcoproparasitologicalmethodinbovineliverswithfascioliasisconvicted
_version_ 1725861294158905344
spelling doaj-3a01966a18794cf683b81a033f7710be2020-11-24T21:55:38ZengUniversidade Federal de Santa MariaCiência Rural0103-84781678-45962012-11-0142112025202910.1590/S0103-84782012001100018Kit comercial de ELISA® para a detecção de coproantígenos e exame coproparasitológico em bovinos com fígados condenados por fasciolose Commercial ELISA® kit for detection of coproantigen and coproparasitological method in bovine livers with fascioliasis convictedCíntia das Chagas BernardoBarbara Rauta de AvelarMariana Drummond Costa IgnacchitiIsabella Vilhena Freire MartinsMaria Julia Salim PereiraObjetivou-se com o presente estudo comparar um kit comercial de ELISA para a detecção de coproantígenos e um exame coproparasitológico de sedimentação utilizando-se como padrão ouro o diagnóstico da inspeção de fígados bovinos ao abate. Além disso, avaliou-se a correlação entre a intensidade parasitária mensurada pela contagem de ovos nas fezes e a de parasitos ao abate. Foram coletadas as fezes e avaliados macroscopicamente os fígados de 81 bovinos, dos quais 45 tiveram os fígados condenados por fasciolose hepática ao abate, nos quais se realizou a contagem dos parasitos. Duas frações de cada amostra de fezes coletadas foram separadas e uma delas foi armazenada em congelador para posterior realização do ELISA e a outra processada segundo uma técnica de sedimentação fecal para diagnóstico de ovos de Fasciola hepatica. O coeficiente de correlação de Spearman e o qui-quadrado de McNemar foram utilizados, adotando-se o nível de significância de 5%. Em oito fígados bovinos condenados por apresentarem lesões características de fasciolose, não foram encontrados exemplares do parasito. O exame coproparasitológico e o ELISA para detecção de coproantígenos, respectivamente, apresentaram sensibilidade de 51,11% e 75,55%, especificidade de 100% e 91,66%, valor preditivivo positivo de 100% e 91,89%, valor preditivo negativo de 62% e 75% e kappa de 0,48 e 0,65. Os resultados obtidos pelo kit ELISA comercial não diferiram (P=0,06) dos obtidos ao abate, mas o exame coproparasitológico diferiu (P<0,0001) do abate na detecção de animais positivos. A correlação entre o número de parasitos no fígado e o número de ovos nas fezes é moderada (rs=0,5757, P<0,0001). O kit ELISA comercial foi mais sensível do que o exame coproparasitológico, embora este não deva ser descartado devido a sua eficiência.<br>The aim of this study was to compare a commercial ELISA kit for detection on coproantigen examination and fecal sedimentation using as gold standard inspection diagnosis of bovine livers at slaughter. In addition, we evaluated the correlation between the measured intensity of infection by counting eggs in the feces and the parasites in bovine livers. Feces were collected and evaluated macroscopically of 81 cattle livers, 45 of which had livers condemned by liver flukes and in these livers parasites were counted. Two fractions of stool samples collected were separated and one stored in freezer for further ELISA and other one processed according to sedimentation technique for diagnosis Fasciola hepatica. The Spearman correlation and McNemar chi-square were used, adopting the significance of 5%. In eight bovine livers condemned by the characteristic lesions of fascioliasis parasite were not found. The stool examinations and ELISA testing for detection coproantigen, respectively, had sensitivity of 51.11% and 75.55%, specificity of 100% and 91,66%, predictive positive value was 100% and 91.89%, predictive negative value 62% and 75% and kappa 0.48 and 0.65. The results obtained by commercial® ELISA kit did not differ (P=0,06) obtained at slaughterhouse, but the stool examinations differed (P<0.0001) in the detection of the positive animals. The correlation between the number of parasites in the liver and the number of eggs in the feces was moderate (rs=0.5757, P<0.0001). The commercial ELISA kit® was more sensitive than the fecal test, althought this one shoud not be discarded because of their efficiency.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782012001100018Fasciola hepaticabovinoimunodiagnósticoFasciola hepaticabovineimmunodiagnosis