Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years

Background: There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed...

Full description

Bibliographic Details
Main Authors: Ethan A. Remily, DO, Scott J. Douglas, MD, Oliver C. Sax, DO, MS, Sahir S. Pervaiz, MD, MS, Nequesha S. Mohamed, MD, Wayne A. Wilkie, DO, MHSA, Langan S. Smith, BS, James Nace, DO, Arthur L. Malkani, MD, Charles E. Jaggard, MS, Frank R. Kolisek, MD, Ronald E. Delanois, MD
Format: Article
Language:English
Published: Elsevier 2021-10-01
Series:Arthroplasty Today
Subjects:
THA
Online Access:http://www.sciencedirect.com/science/article/pii/S2352344121001369
id doaj-39fd9ab3d30043ffa5a1eb29a94102eb
record_format Article
spelling doaj-39fd9ab3d30043ffa5a1eb29a94102eb2021-09-11T04:30:07ZengElsevierArthroplasty Today2352-34412021-10-0111140145Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 YearsEthan A. Remily, DO0Scott J. Douglas, MD1Oliver C. Sax, DO, MS2Sahir S. Pervaiz, MD, MS3Nequesha S. Mohamed, MD4Wayne A. Wilkie, DO, MHSA5Langan S. Smith, BS6James Nace, DO7Arthur L. Malkani, MD8Charles E. Jaggard, MS9Frank R. Kolisek, MD10Ronald E. Delanois, MD11Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USADepartment of Orthopaedic Surgery, University of Louisville Adult Reconstruction Program, Louisville, KY, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USADepartment of Orthopaedic Surgery, University of Louisville Adult Reconstruction Program, Louisville, KY, USAOrthoIndy, Indianapolis, IN, USAOrthoIndy, Indianapolis, IN, USARubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USA; Corresponding author. 2401 West Belvedere Avenue, Baltimore, MD 21215, USA. Tel.: 410-601- 8500.Background: There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed HXLPE. Methods: A retrospective, multicenter study was conducted on patients who underwent primary total hip arthroplasty and received HXLPE polymer (n = 151). Two-dimensional radiographic linear and volumetric wear analyses were quantified using the Martell Hip Analysis software, while functional outcomes were assessed by analyzing postoperative Short-Form-12 (SF-12) Physical and Mental Health Surveys and Harris Hip Scores. Radiographic outcomes included yearly linear (mm/y) and volumetric (mm3/y) wear rates. Surgical outcomes included additional operations and survivorship. Results: SF-12 scores were within 1 standard deviation (SD) of the normal population (SF-12 Physical: 47.0; SF-12 Mental: 52.0), while the Harris Hip Scores of 89.5 was borderline between “good” and “excellent.” Total and annual linear wear rates were 0.164 mm (SD: 0.199 mm) and 0.015 mm/y (SD: 0.018 mm/y), respectively. The mean total volumetric wear rate was 141.4 mm3 (SD: 165.0) and 12.6 mm3/y (SD: 14.9 mm3/y) when broken down into a yearly rate. Eleven patients required revisions, resulting in an all-cause polyethylene survivorship of 92.7%, with a polyethylene wear survivorship of 100.0%. Conclusions: Our results demonstrate clinically undetectable linear and volumetric wear rates after 10 years in those who received the unique sequentially irradiated and annealed HXLPE. Furthermore, high rates of survivorship coupled with low all-cause revision rates illustrate the polymers' capability to potentially increase implant longevity.http://www.sciencedirect.com/science/article/pii/S2352344121001369WearHXLPESurvivorshipTHAArthroplastyFunctional
collection DOAJ
language English
format Article
sources DOAJ
author Ethan A. Remily, DO
Scott J. Douglas, MD
Oliver C. Sax, DO, MS
Sahir S. Pervaiz, MD, MS
Nequesha S. Mohamed, MD
Wayne A. Wilkie, DO, MHSA
Langan S. Smith, BS
James Nace, DO
Arthur L. Malkani, MD
Charles E. Jaggard, MS
Frank R. Kolisek, MD
Ronald E. Delanois, MD
spellingShingle Ethan A. Remily, DO
Scott J. Douglas, MD
Oliver C. Sax, DO, MS
Sahir S. Pervaiz, MD, MS
Nequesha S. Mohamed, MD
Wayne A. Wilkie, DO, MHSA
Langan S. Smith, BS
James Nace, DO
Arthur L. Malkani, MD
Charles E. Jaggard, MS
Frank R. Kolisek, MD
Ronald E. Delanois, MD
Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
Arthroplasty Today
Wear
HXLPE
Survivorship
THA
Arthroplasty
Functional
author_facet Ethan A. Remily, DO
Scott J. Douglas, MD
Oliver C. Sax, DO, MS
Sahir S. Pervaiz, MD, MS
Nequesha S. Mohamed, MD
Wayne A. Wilkie, DO, MHSA
Langan S. Smith, BS
James Nace, DO
Arthur L. Malkani, MD
Charles E. Jaggard, MS
Frank R. Kolisek, MD
Ronald E. Delanois, MD
author_sort Ethan A. Remily, DO
title Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
title_short Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
title_full Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
title_fullStr Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
title_full_unstemmed Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
title_sort sequentially irradiated and annealed highly cross-linked polyethylene: linear vector and volumetric wear in total hip arthroplasty at 10 years
publisher Elsevier
series Arthroplasty Today
issn 2352-3441
publishDate 2021-10-01
description Background: There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed HXLPE. Methods: A retrospective, multicenter study was conducted on patients who underwent primary total hip arthroplasty and received HXLPE polymer (n = 151). Two-dimensional radiographic linear and volumetric wear analyses were quantified using the Martell Hip Analysis software, while functional outcomes were assessed by analyzing postoperative Short-Form-12 (SF-12) Physical and Mental Health Surveys and Harris Hip Scores. Radiographic outcomes included yearly linear (mm/y) and volumetric (mm3/y) wear rates. Surgical outcomes included additional operations and survivorship. Results: SF-12 scores were within 1 standard deviation (SD) of the normal population (SF-12 Physical: 47.0; SF-12 Mental: 52.0), while the Harris Hip Scores of 89.5 was borderline between “good” and “excellent.” Total and annual linear wear rates were 0.164 mm (SD: 0.199 mm) and 0.015 mm/y (SD: 0.018 mm/y), respectively. The mean total volumetric wear rate was 141.4 mm3 (SD: 165.0) and 12.6 mm3/y (SD: 14.9 mm3/y) when broken down into a yearly rate. Eleven patients required revisions, resulting in an all-cause polyethylene survivorship of 92.7%, with a polyethylene wear survivorship of 100.0%. Conclusions: Our results demonstrate clinically undetectable linear and volumetric wear rates after 10 years in those who received the unique sequentially irradiated and annealed HXLPE. Furthermore, high rates of survivorship coupled with low all-cause revision rates illustrate the polymers' capability to potentially increase implant longevity.
topic Wear
HXLPE
Survivorship
THA
Arthroplasty
Functional
url http://www.sciencedirect.com/science/article/pii/S2352344121001369
work_keys_str_mv AT ethanaremilydo sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT scottjdouglasmd sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT olivercsaxdoms sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT sahirspervaizmdms sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT nequeshasmohamedmd sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT wayneawilkiedomhsa sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT langanssmithbs sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT jamesnacedo sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT arthurlmalkanimd sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT charlesejaggardms sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT frankrkolisekmd sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
AT ronaldedelanoismd sequentiallyirradiatedandannealedhighlycrosslinkedpolyethylenelinearvectorandvolumetricwearintotalhiparthroplastyat10years
_version_ 1717757147165491200