A Black-Box External Equivalent Method Using Tie-Line Power Mutation
A new black-box equivalent method by using tie-line power mutation is proposed in this paper, which is especially suitable for a two-port or three-port interconnected grid that does not know any information of the external network. The proposed method, based on the simplified Ward equivalent model o...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8610017/ |
id |
doaj-39c64709ef3046069313eaf5d3465732 |
---|---|
record_format |
Article |
spelling |
doaj-39c64709ef3046069313eaf5d34657322021-03-29T22:02:43ZengIEEEIEEE Access2169-35362019-01-017119971200510.1109/ACCESS.2019.28920608610017A Black-Box External Equivalent Method Using Tie-Line Power MutationWei Yan0Chao Zhang1https://orcid.org/0000-0001-7209-8703Junjie Tang2Wei Qian3Shiming Li4Qian Wang5State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaState Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, ChinaPower Dispatching Control Center, Guangdong Grid Company, Guangzhou, ChinaState Grid Deyang Power Supply Company, Deyang, ChinaA new black-box equivalent method by using tie-line power mutation is proposed in this paper, which is especially suitable for a two-port or three-port interconnected grid that does not know any information of the external network. The proposed method, based on the simplified Ward equivalent model of the external network, aims to addresses the following issues: unstable parameter estimation of the existing black-box-based static equivalence method and low accuracy or difficult implementation. Correspondingly, the main features of the proposed method, which makes it as a solution for these existing issues above, are summarized as follows: 1) it is easy to implement, as it only involves the associated measurements of boundary nodes in two adjacent time instants that are before and after a designed large disturbance of the internal grid; 2) it is robust to measurement errors, thus guaranteeing more accurate equivalent modeling; and 3) it can be applied to both the two-port and three-port equivalent networks. The simulation results of the New England 39-node test case and the actual electric grid case in Guangdong of China validate the effectiveness and performance of the proposed method.https://ieeexplore.ieee.org/document/8610017/Static equivalent methodblack-box external networkparameter estimationtie linepower mutation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wei Yan Chao Zhang Junjie Tang Wei Qian Shiming Li Qian Wang |
spellingShingle |
Wei Yan Chao Zhang Junjie Tang Wei Qian Shiming Li Qian Wang A Black-Box External Equivalent Method Using Tie-Line Power Mutation IEEE Access Static equivalent method black-box external network parameter estimation tie line power mutation |
author_facet |
Wei Yan Chao Zhang Junjie Tang Wei Qian Shiming Li Qian Wang |
author_sort |
Wei Yan |
title |
A Black-Box External Equivalent Method Using Tie-Line Power Mutation |
title_short |
A Black-Box External Equivalent Method Using Tie-Line Power Mutation |
title_full |
A Black-Box External Equivalent Method Using Tie-Line Power Mutation |
title_fullStr |
A Black-Box External Equivalent Method Using Tie-Line Power Mutation |
title_full_unstemmed |
A Black-Box External Equivalent Method Using Tie-Line Power Mutation |
title_sort |
black-box external equivalent method using tie-line power mutation |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2019-01-01 |
description |
A new black-box equivalent method by using tie-line power mutation is proposed in this paper, which is especially suitable for a two-port or three-port interconnected grid that does not know any information of the external network. The proposed method, based on the simplified Ward equivalent model of the external network, aims to addresses the following issues: unstable parameter estimation of the existing black-box-based static equivalence method and low accuracy or difficult implementation. Correspondingly, the main features of the proposed method, which makes it as a solution for these existing issues above, are summarized as follows: 1) it is easy to implement, as it only involves the associated measurements of boundary nodes in two adjacent time instants that are before and after a designed large disturbance of the internal grid; 2) it is robust to measurement errors, thus guaranteeing more accurate equivalent modeling; and 3) it can be applied to both the two-port and three-port equivalent networks. The simulation results of the New England 39-node test case and the actual electric grid case in Guangdong of China validate the effectiveness and performance of the proposed method. |
topic |
Static equivalent method black-box external network parameter estimation tie line power mutation |
url |
https://ieeexplore.ieee.org/document/8610017/ |
work_keys_str_mv |
AT weiyan ablackboxexternalequivalentmethodusingtielinepowermutation AT chaozhang ablackboxexternalequivalentmethodusingtielinepowermutation AT junjietang ablackboxexternalequivalentmethodusingtielinepowermutation AT weiqian ablackboxexternalequivalentmethodusingtielinepowermutation AT shimingli ablackboxexternalequivalentmethodusingtielinepowermutation AT qianwang ablackboxexternalequivalentmethodusingtielinepowermutation AT weiyan blackboxexternalequivalentmethodusingtielinepowermutation AT chaozhang blackboxexternalequivalentmethodusingtielinepowermutation AT junjietang blackboxexternalequivalentmethodusingtielinepowermutation AT weiqian blackboxexternalequivalentmethodusingtielinepowermutation AT shimingli blackboxexternalequivalentmethodusingtielinepowermutation AT qianwang blackboxexternalequivalentmethodusingtielinepowermutation |
_version_ |
1724192259697541120 |