Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load

Considering the growing trend of the consumption of the electric power and the global tendency to substitute new renewable sources of energy, this paper proposes a Monte Carlo based method to determine an optimal level of this change. Considering the limitation of the wind farms in continuous supply...

Full description

Bibliographic Details
Main Authors: Shahrokh Shojaeean, Hadi Akrami
Format: Article
Language:English
Published: Najafabad Branch, Islamic Azad University 2013-04-01
Series:Journal of Intelligent Procedures in Electrical Technology
Subjects:
Online Access:http://jipet.iaun.ac.ir/pdf_4166_2487ffd36a6d99312eb4d6963af55cda.html
id doaj-39a69cc7171c4b72a39600c2af2a0c35
record_format Article
spelling doaj-39a69cc7171c4b72a39600c2af2a0c352020-11-24T23:40:59ZengNajafabad Branch, Islamic Azad UniversityJournal of Intelligent Procedures in Electrical Technology2322-38712345-55942013-04-014143140Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth LoadShahrokh Shojaeean0Hadi Akrami1Islamic Azad University, Khomeini Shahr BranchIslamic Azad University, Khomeini Shahr BranchConsidering the growing trend of the consumption of the electric power and the global tendency to substitute new renewable sources of energy, this paper proposes a Monte Carlo based method to determine an optimal level of this change. Considering the limitation of the wind farms in continuous supply of electric power, hydrostatic power storage facilities are used beside wind farms so that the electric power could be stored and fed in a continuous flow into power systems. Due to the gradual exclusion of conventional generators and 5 percent annual load increments, LOLE index was used in order to calculate the amount of the wind power and the capacity of the necessary power storage facility. To this end, LOLE index was calculated for the first year as the reference index for the estimation of the amount of wind power and the capacity of the storage facility in consequent years. For the upcoming years, calculations have been made to account for the gradual exclusion of conventional generators in proportion to load increments. The proposed method has been implemented and simulated on IEEE-RTS test system.http://jipet.iaun.ac.ir/pdf_4166_2487ffd36a6d99312eb4d6963af55cda.htmlWind powerHydroelectric storageReliabilityMonte CarloLOLE
collection DOAJ
language English
format Article
sources DOAJ
author Shahrokh Shojaeean
Hadi Akrami
spellingShingle Shahrokh Shojaeean
Hadi Akrami
Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
Journal of Intelligent Procedures in Electrical Technology
Wind power
Hydroelectric storage
Reliability
Monte Carlo
LOLE
author_facet Shahrokh Shojaeean
Hadi Akrami
author_sort Shahrokh Shojaeean
title Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
title_short Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
title_full Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
title_fullStr Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
title_full_unstemmed Coordination Between Wind Power, Hydro Storage Facility and Conventional Generating Units According to the Annual Growth Load
title_sort coordination between wind power, hydro storage facility and conventional generating units according to the annual growth load
publisher Najafabad Branch, Islamic Azad University
series Journal of Intelligent Procedures in Electrical Technology
issn 2322-3871
2345-5594
publishDate 2013-04-01
description Considering the growing trend of the consumption of the electric power and the global tendency to substitute new renewable sources of energy, this paper proposes a Monte Carlo based method to determine an optimal level of this change. Considering the limitation of the wind farms in continuous supply of electric power, hydrostatic power storage facilities are used beside wind farms so that the electric power could be stored and fed in a continuous flow into power systems. Due to the gradual exclusion of conventional generators and 5 percent annual load increments, LOLE index was used in order to calculate the amount of the wind power and the capacity of the necessary power storage facility. To this end, LOLE index was calculated for the first year as the reference index for the estimation of the amount of wind power and the capacity of the storage facility in consequent years. For the upcoming years, calculations have been made to account for the gradual exclusion of conventional generators in proportion to load increments. The proposed method has been implemented and simulated on IEEE-RTS test system.
topic Wind power
Hydroelectric storage
Reliability
Monte Carlo
LOLE
url http://jipet.iaun.ac.ir/pdf_4166_2487ffd36a6d99312eb4d6963af55cda.html
work_keys_str_mv AT shahrokhshojaeean coordinationbetweenwindpowerhydrostoragefacilityandconventionalgeneratingunitsaccordingtotheannualgrowthload
AT hadiakrami coordinationbetweenwindpowerhydrostoragefacilityandconventionalgeneratingunitsaccordingtotheannualgrowthload
_version_ 1725508417096777728