The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment
Top of line (TOL) corrosion is a common corrosion case found on pipe that flows wet gas in oil and gas industry. The present study aims to evaluate the impact of mono ethylene glycol (MEG) on the TOL corrosion rate of low carbon steel in acidic environment with increased temperature. The study was c...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2019-06-01
|
Series: | Heliyon |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S240584401935652X |
id |
doaj-38f3530eb7c54a40bece66e178fc9003 |
---|---|
record_format |
Article |
spelling |
doaj-38f3530eb7c54a40bece66e178fc90032020-11-25T02:14:03ZengElsevierHeliyon2405-84402019-06-0156e02006The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environmentBambang Widyanto0I. Gede Bagus Eka Suputra Wiguna1Corresponding author.; Materials Engineering, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Ganesha 10, Bandung 40132, IndonesiaMaterials Engineering, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Ganesha 10, Bandung 40132, IndonesiaTop of line (TOL) corrosion is a common corrosion case found on pipe that flows wet gas in oil and gas industry. The present study aims to evaluate the impact of mono ethylene glycol (MEG) on the TOL corrosion rate of low carbon steel in acidic environment with increased temperature. The study was conducted at temperature 50 °C and 70 °C in a solution containing 2000 ppm of acetic acid and 50 % volume of MEG. There are four types of experimental conditions with variation in the temperature and MEG content were used. The result present that MEG effectively reduce the condensation rate and TOL corrosion rate of low carbon steel at elevated temperature environment. This revealed that increasing of TOL corrosion inhibition effect along the experimental period. Moreover, the increased level of severity was associated with increased temperature. The results concluded that this procedure resulted due to decrease in condensation rate that is likely to reduce the supply of electrolyte for the corrosion reaction.http://www.sciencedirect.com/science/article/pii/S240584401935652XMaterials scienceTOL corrosionAcetic acidMEGCondensation rate |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bambang Widyanto I. Gede Bagus Eka Suputra Wiguna |
spellingShingle |
Bambang Widyanto I. Gede Bagus Eka Suputra Wiguna The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment Heliyon Materials science TOL corrosion Acetic acid MEG Condensation rate |
author_facet |
Bambang Widyanto I. Gede Bagus Eka Suputra Wiguna |
author_sort |
Bambang Widyanto |
title |
The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
title_short |
The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
title_full |
The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
title_fullStr |
The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
title_full_unstemmed |
The effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
title_sort |
effect of mono ethylene glycol on the top of line corrosion rate of low carbon steel in acetic acid and elevated temperature environment |
publisher |
Elsevier |
series |
Heliyon |
issn |
2405-8440 |
publishDate |
2019-06-01 |
description |
Top of line (TOL) corrosion is a common corrosion case found on pipe that flows wet gas in oil and gas industry. The present study aims to evaluate the impact of mono ethylene glycol (MEG) on the TOL corrosion rate of low carbon steel in acidic environment with increased temperature. The study was conducted at temperature 50 °C and 70 °C in a solution containing 2000 ppm of acetic acid and 50 % volume of MEG. There are four types of experimental conditions with variation in the temperature and MEG content were used. The result present that MEG effectively reduce the condensation rate and TOL corrosion rate of low carbon steel at elevated temperature environment. This revealed that increasing of TOL corrosion inhibition effect along the experimental period. Moreover, the increased level of severity was associated with increased temperature. The results concluded that this procedure resulted due to decrease in condensation rate that is likely to reduce the supply of electrolyte for the corrosion reaction. |
topic |
Materials science TOL corrosion Acetic acid MEG Condensation rate |
url |
http://www.sciencedirect.com/science/article/pii/S240584401935652X |
work_keys_str_mv |
AT bambangwidyanto theeffectofmonoethyleneglycolonthetopoflinecorrosionrateoflowcarbonsteelinaceticacidandelevatedtemperatureenvironment AT igedebagusekasuputrawiguna theeffectofmonoethyleneglycolonthetopoflinecorrosionrateoflowcarbonsteelinaceticacidandelevatedtemperatureenvironment AT bambangwidyanto effectofmonoethyleneglycolonthetopoflinecorrosionrateoflowcarbonsteelinaceticacidandelevatedtemperatureenvironment AT igedebagusekasuputrawiguna effectofmonoethyleneglycolonthetopoflinecorrosionrateoflowcarbonsteelinaceticacidandelevatedtemperatureenvironment |
_version_ |
1724902329424019456 |