The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis

Purpose: To determine whether radiomics texture features can be reproducibly obtained from megavoltage computed tomographic (MVCT) images acquired by Helical TomoTherapy (HT) with different imaging conditions.Methods: For each of the 195 textures enrolled, the mean intrapatient difference, which is...

Full description

Bibliographic Details
Main Authors: Jiabing Gu, Jian Zhu, Qingtao Qiu, Yungang Wang, Tong Bai, Jinghao Duan, Yong Yin
Format: Article
Language:English
Published: Frontiers Media S.A. 2018-12-01
Series:Frontiers in Oncology
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fonc.2018.00586/full
id doaj-38c7748d4fca497b84530a8d7fd4338f
record_format Article
spelling doaj-38c7748d4fca497b84530a8d7fd4338f2020-11-25T00:30:00ZengFrontiers Media S.A.Frontiers in Oncology2234-943X2018-12-01810.3389/fonc.2018.00586418830The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature AnalysisJiabing Gu0Jiabing Gu1Jian Zhu2Qingtao Qiu3Yungang Wang4Tong Bai5Jinghao Duan6Yong Yin7School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, ChinaPurpose: To determine whether radiomics texture features can be reproducibly obtained from megavoltage computed tomographic (MVCT) images acquired by Helical TomoTherapy (HT) with different imaging conditions.Methods: For each of the 195 textures enrolled, the mean intrapatient difference, which is considered to be the benchmark for reproducibility, was calculated from the MVCT images of 22 patients with early-stage non-small-cell lung cancer. Test–retest MVCT images of an in-house designed phantom were acquired to determine the concordance correlation coefficient (CCC) for these 195 texture features. Features with high reproducibility (CCC > 0.9) in the phantom test–retest set were investigated for sensitivities to different imaging protocols, scatter levels, and motion frequencies using a wood phantom and in-vitro animal tissues.Results: Of the 195 features, 165 (85%) features had CCC > 0.9. For the wood phantom, 124 features were reproducible in two kinds of scatter materials, and further investigations were performed on these features. For animal tissues, 108 features passed the criteria for reproducibility when one layer of scatter was covered, while 106 and 108 features of in-vitro liver and bone passed with two layers of scatter, respectively. Considering the effect of differing acquisition pitch (AcP), 97 features extracted from wood passed, while 103 and 59 features extracted from in-vitro liver and bone passed, respectively. Different reconstruction intervals (RI) had a small effect on the stability of the feature value. When AcP and RI were held consistent without motion, all 124 features calculated from wood passed, and a majority (122 of 124) of the features passed when imaging with a “fine” AcP with different RIs. However, only 55 and 40 features passed with motion frequencies of 20 and 25 beats per minute, respectively.Conclusion: Motion frequency has a significant impact on MVCT texture features, and features from MVCT were more reproducibility in different scatter conditions than those from CBCT. Considering the effects of AcP and RI, the scanning protocols should be kept consistent when MVCT images are used for feature analysis. Some radiomics features from HT MVCT images are reproducible and could be used for creating clinical prediction models in the future.https://www.frontiersin.org/article/10.3389/fonc.2018.00586/fullradiotherapyhelical tomotherpymegavoltage computed tomotherapyradiomicsfeature analysis
collection DOAJ
language English
format Article
sources DOAJ
author Jiabing Gu
Jiabing Gu
Jian Zhu
Qingtao Qiu
Yungang Wang
Tong Bai
Jinghao Duan
Yong Yin
spellingShingle Jiabing Gu
Jiabing Gu
Jian Zhu
Qingtao Qiu
Yungang Wang
Tong Bai
Jinghao Duan
Yong Yin
The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
Frontiers in Oncology
radiotherapy
helical tomotherpy
megavoltage computed tomotherapy
radiomics
feature analysis
author_facet Jiabing Gu
Jiabing Gu
Jian Zhu
Qingtao Qiu
Yungang Wang
Tong Bai
Jinghao Duan
Yong Yin
author_sort Jiabing Gu
title The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
title_short The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
title_full The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
title_fullStr The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
title_full_unstemmed The Feasibility Study of Megavoltage Computed Tomographic (MVCT) Image for Texture Feature Analysis
title_sort feasibility study of megavoltage computed tomographic (mvct) image for texture feature analysis
publisher Frontiers Media S.A.
series Frontiers in Oncology
issn 2234-943X
publishDate 2018-12-01
description Purpose: To determine whether radiomics texture features can be reproducibly obtained from megavoltage computed tomographic (MVCT) images acquired by Helical TomoTherapy (HT) with different imaging conditions.Methods: For each of the 195 textures enrolled, the mean intrapatient difference, which is considered to be the benchmark for reproducibility, was calculated from the MVCT images of 22 patients with early-stage non-small-cell lung cancer. Test–retest MVCT images of an in-house designed phantom were acquired to determine the concordance correlation coefficient (CCC) for these 195 texture features. Features with high reproducibility (CCC > 0.9) in the phantom test–retest set were investigated for sensitivities to different imaging protocols, scatter levels, and motion frequencies using a wood phantom and in-vitro animal tissues.Results: Of the 195 features, 165 (85%) features had CCC > 0.9. For the wood phantom, 124 features were reproducible in two kinds of scatter materials, and further investigations were performed on these features. For animal tissues, 108 features passed the criteria for reproducibility when one layer of scatter was covered, while 106 and 108 features of in-vitro liver and bone passed with two layers of scatter, respectively. Considering the effect of differing acquisition pitch (AcP), 97 features extracted from wood passed, while 103 and 59 features extracted from in-vitro liver and bone passed, respectively. Different reconstruction intervals (RI) had a small effect on the stability of the feature value. When AcP and RI were held consistent without motion, all 124 features calculated from wood passed, and a majority (122 of 124) of the features passed when imaging with a “fine” AcP with different RIs. However, only 55 and 40 features passed with motion frequencies of 20 and 25 beats per minute, respectively.Conclusion: Motion frequency has a significant impact on MVCT texture features, and features from MVCT were more reproducibility in different scatter conditions than those from CBCT. Considering the effects of AcP and RI, the scanning protocols should be kept consistent when MVCT images are used for feature analysis. Some radiomics features from HT MVCT images are reproducible and could be used for creating clinical prediction models in the future.
topic radiotherapy
helical tomotherpy
megavoltage computed tomotherapy
radiomics
feature analysis
url https://www.frontiersin.org/article/10.3389/fonc.2018.00586/full
work_keys_str_mv AT jiabinggu thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jiabinggu thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jianzhu thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT qingtaoqiu thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT yungangwang thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT tongbai thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jinghaoduan thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT yongyin thefeasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jiabinggu feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jiabinggu feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jianzhu feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT qingtaoqiu feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT yungangwang feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT tongbai feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT jinghaoduan feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
AT yongyin feasibilitystudyofmegavoltagecomputedtomographicmvctimagefortexturefeatureanalysis
_version_ 1725328549594791936