Optimal Screw Fixation in Treating Jones Fractures

Category: Midfoot/Forefoot Introduction/Purpose: Jones fractures are among the most common fractures in the foot, mainly occurring in athletes. In order to facilitate return to sport and good functional outcomes, management with intramedullary screw fixation is often recommended [1-3]. While optimal...

Full description

Bibliographic Details
Main Authors: Ali Hosseini PhD, Pim Van Dijk BSc(Med), Sofie Breuking MSc, Bryan Vopat MD, Daniel Guss MD, MBA, A. Holly Johnson MD, Christopher DiGiovanni MD
Format: Article
Language:English
Published: SAGE Publishing 2017-09-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011417S000197
id doaj-389bed0ccd564ed89767c66aba57c478
record_format Article
spelling doaj-389bed0ccd564ed89767c66aba57c4782020-11-25T03:33:53ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142017-09-01210.1177/2473011417S000197Optimal Screw Fixation in Treating Jones FracturesAli Hosseini PhDPim Van Dijk BSc(Med)Sofie Breuking MScBryan Vopat MDDaniel Guss MD, MBAA. Holly Johnson MDChristopher DiGiovanni MDCategory: Midfoot/Forefoot Introduction/Purpose: Jones fractures are among the most common fractures in the foot, mainly occurring in athletes. In order to facilitate return to sport and good functional outcomes, management with intramedullary screw fixation is often recommended [1-3]. While optimal screw dimension and location parameters have varied in the literature, it is clear that maximizing pull-out strength, providing adequate compression across the fracture, and minimizing irritation to surrounding soft tissue structures are of paramount importance. The aim of this study was to improve our guidelines regarding optimal insertion trajectory and screw parameters of Jones fractures by more accurately defining the bony and soft tissue anatomy of the fifth metatarsal bone and its intramedullary canal. Methods: 21 fifth metatarsal bones were harvested from cadaveric feet. Three reference screws were placed on each bone for registration. 3D CT model of each bone with outer cortex, intramedullary canal and the articular cortex was created (Figure A). The insertions of the PB and PF and the reference screws of each bone were carefully digitized and mapped onto corresponding 3D model. The anatomic insertions and the surface areas were determined. Based on the length of the bone, the shape of the intramedullary canal, and the diameter of the canal at its narrowest point, the perceived ideal screw and placement was then modulated for each bone model. Also, the fracture zone where Jones fractures occur was determined (Figure B) based on Lawrence/Botte classification [1]. Screw and thread length were calculated in this position, and the impact of screw placement on the insertion sites of both the PB and PF were recorded. Results: The mean length of the bones was 74.4±3.6 mm, with the narrowest diameter of the intramedullary canal being 4.3±0.7 mm. Ideal screw position was identified as parallel to the cuboid and coaxial with the intramedullary cortex; this placement, however, was found to partially sacrifice the PB and PF insertions in 62% (13/21) and 33% (7/21) of cases, respectively; with an average of 1.6±0.8 mm of the PB and 1.3±0.8 mm of the PF insertion. The mean ideal screw length in this position was found to be 47.8±5.8 mm, with a minimal thread length of 28±6.8 mm and a minimal diameter of 4.5 mm (Figure B). The ratio of screw length to the total bone length was 0.64 (range 0.50-0.72). Conclusion: In order to maximize compression and pull-out strength and minimize sacrifice of the adjacent soft tissue structures during screw placement, Jones fractures should be fixed with hardware parallel to the cuboid and collinear with the intramedullary cortex—which mitigates but does not avoid injury to the peroneal tendon and plantar fascia. Average optimal length of the screw should be 64% of the length of the bone, with a minimum 4.5 mm diameter and 50% thread length (relative to bone length). Given variability in metatarsal anatomy, screw choice should be tailored to the individual.https://doi.org/10.1177/2473011417S000197
collection DOAJ
language English
format Article
sources DOAJ
author Ali Hosseini PhD
Pim Van Dijk BSc(Med)
Sofie Breuking MSc
Bryan Vopat MD
Daniel Guss MD, MBA
A. Holly Johnson MD
Christopher DiGiovanni MD
spellingShingle Ali Hosseini PhD
Pim Van Dijk BSc(Med)
Sofie Breuking MSc
Bryan Vopat MD
Daniel Guss MD, MBA
A. Holly Johnson MD
Christopher DiGiovanni MD
Optimal Screw Fixation in Treating Jones Fractures
Foot & Ankle Orthopaedics
author_facet Ali Hosseini PhD
Pim Van Dijk BSc(Med)
Sofie Breuking MSc
Bryan Vopat MD
Daniel Guss MD, MBA
A. Holly Johnson MD
Christopher DiGiovanni MD
author_sort Ali Hosseini PhD
title Optimal Screw Fixation in Treating Jones Fractures
title_short Optimal Screw Fixation in Treating Jones Fractures
title_full Optimal Screw Fixation in Treating Jones Fractures
title_fullStr Optimal Screw Fixation in Treating Jones Fractures
title_full_unstemmed Optimal Screw Fixation in Treating Jones Fractures
title_sort optimal screw fixation in treating jones fractures
publisher SAGE Publishing
series Foot & Ankle Orthopaedics
issn 2473-0114
publishDate 2017-09-01
description Category: Midfoot/Forefoot Introduction/Purpose: Jones fractures are among the most common fractures in the foot, mainly occurring in athletes. In order to facilitate return to sport and good functional outcomes, management with intramedullary screw fixation is often recommended [1-3]. While optimal screw dimension and location parameters have varied in the literature, it is clear that maximizing pull-out strength, providing adequate compression across the fracture, and minimizing irritation to surrounding soft tissue structures are of paramount importance. The aim of this study was to improve our guidelines regarding optimal insertion trajectory and screw parameters of Jones fractures by more accurately defining the bony and soft tissue anatomy of the fifth metatarsal bone and its intramedullary canal. Methods: 21 fifth metatarsal bones were harvested from cadaveric feet. Three reference screws were placed on each bone for registration. 3D CT model of each bone with outer cortex, intramedullary canal and the articular cortex was created (Figure A). The insertions of the PB and PF and the reference screws of each bone were carefully digitized and mapped onto corresponding 3D model. The anatomic insertions and the surface areas were determined. Based on the length of the bone, the shape of the intramedullary canal, and the diameter of the canal at its narrowest point, the perceived ideal screw and placement was then modulated for each bone model. Also, the fracture zone where Jones fractures occur was determined (Figure B) based on Lawrence/Botte classification [1]. Screw and thread length were calculated in this position, and the impact of screw placement on the insertion sites of both the PB and PF were recorded. Results: The mean length of the bones was 74.4±3.6 mm, with the narrowest diameter of the intramedullary canal being 4.3±0.7 mm. Ideal screw position was identified as parallel to the cuboid and coaxial with the intramedullary cortex; this placement, however, was found to partially sacrifice the PB and PF insertions in 62% (13/21) and 33% (7/21) of cases, respectively; with an average of 1.6±0.8 mm of the PB and 1.3±0.8 mm of the PF insertion. The mean ideal screw length in this position was found to be 47.8±5.8 mm, with a minimal thread length of 28±6.8 mm and a minimal diameter of 4.5 mm (Figure B). The ratio of screw length to the total bone length was 0.64 (range 0.50-0.72). Conclusion: In order to maximize compression and pull-out strength and minimize sacrifice of the adjacent soft tissue structures during screw placement, Jones fractures should be fixed with hardware parallel to the cuboid and collinear with the intramedullary cortex—which mitigates but does not avoid injury to the peroneal tendon and plantar fascia. Average optimal length of the screw should be 64% of the length of the bone, with a minimum 4.5 mm diameter and 50% thread length (relative to bone length). Given variability in metatarsal anatomy, screw choice should be tailored to the individual.
url https://doi.org/10.1177/2473011417S000197
work_keys_str_mv AT alihosseiniphd optimalscrewfixationintreatingjonesfractures
AT pimvandijkbscmed optimalscrewfixationintreatingjonesfractures
AT sofiebreukingmsc optimalscrewfixationintreatingjonesfractures
AT bryanvopatmd optimalscrewfixationintreatingjonesfractures
AT danielgussmdmba optimalscrewfixationintreatingjonesfractures
AT ahollyjohnsonmd optimalscrewfixationintreatingjonesfractures
AT christopherdigiovannimd optimalscrewfixationintreatingjonesfractures
_version_ 1724561186053160960