Radiofrequency transmyocardial revascularization in experiment

Conducted benchmark analysis of influence to mechanical punctures, transmyocardial radiofrequency influence and lazer radiating on myocardium. Study is conducted on 284 rats. Transmyocardial revascularization (ТМR) was executed with use intramuscular needle, Nd:YAG lazer, radiofrequency generator wi...

Full description

Bibliographic Details
Main Authors: A. I. Opherkin, S. V. Logvinov, Y. A. Pokushalov
Format: Article
Language:English
Published: Siberian State Medical University (Tomsk) 2002-09-01
Series:Bûlleten' Sibirskoj Mediciny
Subjects:
Online Access:https://bulletin.tomsk.ru/jour/article/view/3996
id doaj-38381613bcf342b4a1f5ac43796114f2
record_format Article
spelling doaj-38381613bcf342b4a1f5ac43796114f22021-07-29T08:37:39ZengSiberian State Medical University (Tomsk)Bûlleten' Sibirskoj Mediciny1682-03631819-36842002-09-0113394510.20538/1682-0363-2002-3-39-452600Radiofrequency transmyocardial revascularization in experimentA. I. Opherkin0S. V. Logvinov1Y. A. Pokushalov2НИИ кардиологии ТНЦ СО РАМНСибирский государственный медицинский университетНИИ кардиологии ТНЦ СО РАМНConducted benchmark analysis of influence to mechanical punctures, transmyocardial radiofrequency influence and lazer radiating on myocardium. Study is conducted on 284 rats. Transmyocardial revascularization (ТМR) was executed with use intramuscular needle, Nd:YAG lazer, radiofrequency generator with needle electrode. Study of vascular density and myocardial perfusion was conducted through 1, 2, 4 and 8 weeks. Maximum increasing vascular density was observed on 4 week. In groups with radiofrequency TMR and Nd:YAG TMR specific vascular volume is enlarged in 5 once (26,9 ± 1,9% and 22,2 ± 1,7%, accordingly; Р < 0,05) in contrast with the checking group (4,9 ± 1,6%). In the group with mechanical ТМР specific vascular volume is enlarged small (6,1 ± 1,3%). Increasing an accumulation 99mTc-myoview in the group with radiofrequency TMR occurred on 8 week by comparing with the checking group, it has formed 2,82 ± 0,31% (Р < 0,05) and 1,68 ± 0,21% accordingly. Conclusion: Analysis of vascular density points to alike efficiency of lazer and radiofrequency transmyocardial revascularization. Radiofrequency ТМR causes an increasing vascular density and improvement myocardial perfusion in ischemic myocardium.https://bulletin.tomsk.ru/jour/article/view/3996ischemic heart diseasetransmyocardial revascularizationradiofrequency energylaser
collection DOAJ
language English
format Article
sources DOAJ
author A. I. Opherkin
S. V. Logvinov
Y. A. Pokushalov
spellingShingle A. I. Opherkin
S. V. Logvinov
Y. A. Pokushalov
Radiofrequency transmyocardial revascularization in experiment
Bûlleten' Sibirskoj Mediciny
ischemic heart disease
transmyocardial revascularization
radiofrequency energy
laser
author_facet A. I. Opherkin
S. V. Logvinov
Y. A. Pokushalov
author_sort A. I. Opherkin
title Radiofrequency transmyocardial revascularization in experiment
title_short Radiofrequency transmyocardial revascularization in experiment
title_full Radiofrequency transmyocardial revascularization in experiment
title_fullStr Radiofrequency transmyocardial revascularization in experiment
title_full_unstemmed Radiofrequency transmyocardial revascularization in experiment
title_sort radiofrequency transmyocardial revascularization in experiment
publisher Siberian State Medical University (Tomsk)
series Bûlleten' Sibirskoj Mediciny
issn 1682-0363
1819-3684
publishDate 2002-09-01
description Conducted benchmark analysis of influence to mechanical punctures, transmyocardial radiofrequency influence and lazer radiating on myocardium. Study is conducted on 284 rats. Transmyocardial revascularization (ТМR) was executed with use intramuscular needle, Nd:YAG lazer, radiofrequency generator with needle electrode. Study of vascular density and myocardial perfusion was conducted through 1, 2, 4 and 8 weeks. Maximum increasing vascular density was observed on 4 week. In groups with radiofrequency TMR and Nd:YAG TMR specific vascular volume is enlarged in 5 once (26,9 ± 1,9% and 22,2 ± 1,7%, accordingly; Р < 0,05) in contrast with the checking group (4,9 ± 1,6%). In the group with mechanical ТМР specific vascular volume is enlarged small (6,1 ± 1,3%). Increasing an accumulation 99mTc-myoview in the group with radiofrequency TMR occurred on 8 week by comparing with the checking group, it has formed 2,82 ± 0,31% (Р < 0,05) and 1,68 ± 0,21% accordingly. Conclusion: Analysis of vascular density points to alike efficiency of lazer and radiofrequency transmyocardial revascularization. Radiofrequency ТМR causes an increasing vascular density and improvement myocardial perfusion in ischemic myocardium.
topic ischemic heart disease
transmyocardial revascularization
radiofrequency energy
laser
url https://bulletin.tomsk.ru/jour/article/view/3996
work_keys_str_mv AT aiopherkin radiofrequencytransmyocardialrevascularizationinexperiment
AT svlogvinov radiofrequencytransmyocardialrevascularizationinexperiment
AT yapokushalov radiofrequencytransmyocardialrevascularizationinexperiment
_version_ 1721254135468130304