See laser testing at different temperatures
The main problem for laser SEE testing at different temperatures is to determine correlation between laser pulse energy and LET. In the first approximation, LET values with the same laser pulse energy and different temperatures are directly proportional to the absorption coefficient of laser light i...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Moscow Engineering Physics Institute
2016-10-01
|
Series: | Bezopasnostʹ Informacionnyh Tehnologij |
Subjects: | |
Online Access: | https://bit.mephi.ru/index.php/bit/article/view/18 |
Summary: | The main problem for laser SEE testing at different temperatures is to determine correlation between laser pulse energy and LET. In the first approximation, LET values with the same laser pulse energy and different temperatures are directly proportional to the absorption coefficient of laser light in a semiconductor. Use of tabulated values could lead to errors and absorption coefficient should be determined for each sensitive volume of device under test (DUT). Temperature dependence of absorption coefficient could be determined using ionization response of DUT in power supply circuit under local laser irradiation. Using this approach a satisfactory correlation of ion and laser SEE test result was observed. |
---|---|
ISSN: | 2074-7128 2074-7136 |