Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System
The aim of this study was to determine the test-retest reliability of an automated infrared-assisted, trunk accelerometer-based gait analysis system for measuring gait parameters of healthy subjects in a hospital. Thirty-five participants (28 of them females; age range, 23–79 years) performed a 5-m...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2016-07-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/16/8/1156 |
id |
doaj-377fb60c194b4b7c905af05d7cd75a18 |
---|---|
record_format |
Article |
spelling |
doaj-377fb60c194b4b7c905af05d7cd75a182020-11-24T21:58:37ZengMDPI AGSensors1424-82202016-07-01168115610.3390/s16081156s16081156Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis SystemChia-Yu Hsu0Yuh-Show Tsai1Cheng-Shiang Yau2Hung-Hai Shie3Chu-Ming Wu4Department of Rehabilitation Medicine, Ten-Chan General Hospital, No. 155, Yanping Rd., Zhongli Dist., Taoyuan City 320, TaiwanDepartment of Biomedical Engineering, Chung Yuan Christian University, No. 200, Zhongbei Rd., Zhongli Dist., Taoyuan City 320, TaiwanDepartment of Biomedical Engineering, Chung Yuan Christian University, No. 200, Zhongbei Rd., Zhongli Dist., Taoyuan City 320, TaiwanDepartment of Physiotherapy, Ten-Chan General Hospital, No. 155, Yanping Rd., Zhongli Dist., Taoyuan City 320, TaiwanDepartment of Rehabilitation Medicine, Ten-Chan General Hospital, No. 155, Yanping Rd., Zhongli Dist., Taoyuan City 320, TaiwanThe aim of this study was to determine the test-retest reliability of an automated infrared-assisted, trunk accelerometer-based gait analysis system for measuring gait parameters of healthy subjects in a hospital. Thirty-five participants (28 of them females; age range, 23–79 years) performed a 5-m walk twice using an accelerometer-based gait analysis system with infrared assist. Measurements of spatiotemporal gait parameters (walking speed, step length, and cadence) and trunk control (gait symmetry, gait regularity, acceleration root mean square (RMS), and acceleration root mean square ratio (RMSR)) were recorded in two separate walking tests conducted 1 week apart. Relative and absolute test-retest reliability was determined by calculating the intra-class correlation coefficient (ICC3,1) and smallest detectable difference (SDD), respectively. The test-retest reliability was excellent for walking speed (ICC = 0.87, 95% confidence interval = 0.74–0.93, SDD = 13.4%), step length (ICC = 0.81, 95% confidence interval = 0.63–0.91, SDD = 12.2%), cadence (ICC = 0.81, 95% confidence interval = 0.63–0.91, SDD = 10.8%), and trunk control (step and stride regularity in anterior-posterior direction, acceleration RMS and acceleration RMSR in medial-lateral direction, and acceleration RMS and stride regularity in vertical direction). An automated infrared-assisted, trunk accelerometer-based gait analysis system is a reliable tool for measuring gait parameters in the hospital environment.http://www.mdpi.com/1424-8220/16/8/1156accelerometrygaitinfraredtrunk accelerationreliability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chia-Yu Hsu Yuh-Show Tsai Cheng-Shiang Yau Hung-Hai Shie Chu-Ming Wu |
spellingShingle |
Chia-Yu Hsu Yuh-Show Tsai Cheng-Shiang Yau Hung-Hai Shie Chu-Ming Wu Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System Sensors accelerometry gait infrared trunk acceleration reliability |
author_facet |
Chia-Yu Hsu Yuh-Show Tsai Cheng-Shiang Yau Hung-Hai Shie Chu-Ming Wu |
author_sort |
Chia-Yu Hsu |
title |
Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System |
title_short |
Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System |
title_full |
Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System |
title_fullStr |
Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System |
title_full_unstemmed |
Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System |
title_sort |
test-retest reliability of an automated infrared-assisted trunk accelerometer-based gait analysis system |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2016-07-01 |
description |
The aim of this study was to determine the test-retest reliability of an automated infrared-assisted, trunk accelerometer-based gait analysis system for measuring gait parameters of healthy subjects in a hospital. Thirty-five participants (28 of them females; age range, 23–79 years) performed a 5-m walk twice using an accelerometer-based gait analysis system with infrared assist. Measurements of spatiotemporal gait parameters (walking speed, step length, and cadence) and trunk control (gait symmetry, gait regularity, acceleration root mean square (RMS), and acceleration root mean square ratio (RMSR)) were recorded in two separate walking tests conducted 1 week apart. Relative and absolute test-retest reliability was determined by calculating the intra-class correlation coefficient (ICC3,1) and smallest detectable difference (SDD), respectively. The test-retest reliability was excellent for walking speed (ICC = 0.87, 95% confidence interval = 0.74–0.93, SDD = 13.4%), step length (ICC = 0.81, 95% confidence interval = 0.63–0.91, SDD = 12.2%), cadence (ICC = 0.81, 95% confidence interval = 0.63–0.91, SDD = 10.8%), and trunk control (step and stride regularity in anterior-posterior direction, acceleration RMS and acceleration RMSR in medial-lateral direction, and acceleration RMS and stride regularity in vertical direction). An automated infrared-assisted, trunk accelerometer-based gait analysis system is a reliable tool for measuring gait parameters in the hospital environment. |
topic |
accelerometry gait infrared trunk acceleration reliability |
url |
http://www.mdpi.com/1424-8220/16/8/1156 |
work_keys_str_mv |
AT chiayuhsu testretestreliabilityofanautomatedinfraredassistedtrunkaccelerometerbasedgaitanalysissystem AT yuhshowtsai testretestreliabilityofanautomatedinfraredassistedtrunkaccelerometerbasedgaitanalysissystem AT chengshiangyau testretestreliabilityofanautomatedinfraredassistedtrunkaccelerometerbasedgaitanalysissystem AT hunghaishie testretestreliabilityofanautomatedinfraredassistedtrunkaccelerometerbasedgaitanalysissystem AT chumingwu testretestreliabilityofanautomatedinfraredassistedtrunkaccelerometerbasedgaitanalysissystem |
_version_ |
1725851117011599360 |