Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol
Introduction. The determination of ethyl glucuronide (EtG), a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, v...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Istituto Superiore di Sanità
2015-03-01
|
Series: | Annali dell'Istituto Superiore di Sanità |
Subjects: | |
Online Access: | http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712015000100005&lng=en&tlng=en |
id |
doaj-3763089b7edd4b7c933930a46f8d025c |
---|---|
record_format |
Article |
spelling |
doaj-3763089b7edd4b7c933930a46f8d025c2020-11-25T03:24:20ZengIstituto Superiore di SanitàAnnali dell'Istituto Superiore di Sanità0021-25712015-03-01511192710.4415/ANN_15_01_05S0021-25712015000100005Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanolSara Vezzoli0Marzia Bernini1Francesco De Ferrari2Università degli Studi di BresciaUniversità degli Studi di BresciaUniversità degli Studi di BresciaIntroduction. The determination of ethyl glucuronide (EtG), a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH), to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was performed using an LC/MS/MS system. Analyses of the ethanol and putrefaction biomarkers, such as acetaldehyde and n-propanol, were performed using the HS-GC/FID technique in both the matrices. Results. In 17 cases, both ethanol and EtG were absent in both matrices.Nineteen cases presented ethanol in blood from 0.05 to 0.30 g/L, EtG-Blood concentration from 0.02 to 3.27 mg/L, and EtG-VH concentration from 0.01 mg/L to 2.88 mg/L. Thirteen cases presented ethanol in blood > 0.05 g/L but EtG concentration in blood and VH lower than 0.01 mg/L, are part of these 8 samples presented acetic aldehyde and n- propanol in blood or VH, means identification of putrefaction indicators. Fourteen cases presented ethanol in blood > 0.46 and EtG concentration in blood and VH higher than 0.01 mg/L. Conclusions. The determination of EtG in biological material is important in those cases where the intake of ethanol appears doubtful, as it allows us to exclude the possibility of any post-mortem formation of ethanol.http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712015000100005&lng=en&tlng=enethyl glucuronideethanolVHperipheral blood |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sara Vezzoli Marzia Bernini Francesco De Ferrari |
spellingShingle |
Sara Vezzoli Marzia Bernini Francesco De Ferrari Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol Annali dell'Istituto Superiore di Sanità ethyl glucuronide ethanol VH peripheral blood |
author_facet |
Sara Vezzoli Marzia Bernini Francesco De Ferrari |
author_sort |
Sara Vezzoli |
title |
Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
title_short |
Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
title_full |
Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
title_fullStr |
Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
title_full_unstemmed |
Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
title_sort |
ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol |
publisher |
Istituto Superiore di Sanità |
series |
Annali dell'Istituto Superiore di Sanità |
issn |
0021-2571 |
publishDate |
2015-03-01 |
description |
Introduction. The determination of ethyl glucuronide (EtG), a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH), to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was performed using an LC/MS/MS system. Analyses of the ethanol and putrefaction biomarkers, such as acetaldehyde and n-propanol, were performed using the HS-GC/FID technique in both the matrices. Results. In 17 cases, both ethanol and EtG were absent in both matrices.Nineteen cases presented ethanol in blood from 0.05 to 0.30 g/L, EtG-Blood concentration from 0.02 to 3.27 mg/L, and EtG-VH concentration from 0.01 mg/L to 2.88 mg/L. Thirteen cases presented ethanol in blood > 0.05 g/L but EtG concentration in blood and VH lower than 0.01 mg/L, are part of these 8 samples presented acetic aldehyde and n- propanol in blood or VH, means identification of putrefaction indicators. Fourteen cases presented ethanol in blood > 0.46 and EtG concentration in blood and VH higher than 0.01 mg/L. Conclusions. The determination of EtG in biological material is important in those cases where the intake of ethanol appears doubtful, as it allows us to exclude the possibility of any post-mortem formation of ethanol. |
topic |
ethyl glucuronide ethanol VH peripheral blood |
url |
http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712015000100005&lng=en&tlng=en |
work_keys_str_mv |
AT saravezzoli ethylglucuronideinvitreoushumorandbloodpostmortemspecimensanalysisbyliquidchromatographyelectrospraytandemmassspectrometryandinterpretingresultsofneoformationofethanol AT marziabernini ethylglucuronideinvitreoushumorandbloodpostmortemspecimensanalysisbyliquidchromatographyelectrospraytandemmassspectrometryandinterpretingresultsofneoformationofethanol AT francescodeferrari ethylglucuronideinvitreoushumorandbloodpostmortemspecimensanalysisbyliquidchromatographyelectrospraytandemmassspectrometryandinterpretingresultsofneoformationofethanol |
_version_ |
1724602109397041152 |