A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow

Background: In the administration of minimal flow anesthesia, traditionally a fixed time period of high flow has been used before changing over to minimal flow. However, newer studies have used "equilibration time" of a volatile anesthetic agent as the change-over point. Materials and Meth...

Full description

Bibliographic Details
Main Authors: Tanuja Mallik, S Aneja, R Tope, V Muralidhar
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2012-01-01
Series:Journal of Anaesthesiology Clinical Pharmacology
Subjects:
Online Access:http://www.joacp.org/article.asp?issn=0970-9185;year=2012;volume=28;issue=4;spage=470;epage=475;aulast=Mallik
id doaj-369fca64d2d54c3e8ea9c71fb528baf3
record_format Article
spelling doaj-369fca64d2d54c3e8ea9c71fb528baf32020-11-24T22:52:45ZengWolters Kluwer Medknow PublicationsJournal of Anaesthesiology Clinical Pharmacology0970-91852012-01-0128447047510.4103/0970-9185.101916A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flowTanuja MallikS AnejaR TopeV MuralidharBackground: In the administration of minimal flow anesthesia, traditionally a fixed time period of high flow has been used before changing over to minimal flow. However, newer studies have used "equilibration time" of a volatile anesthetic agent as the change-over point. Materials and Methods: A randomized prospective study was conducted on 60 patients, who were divided into two groups of 30 patients each. Two volatile inhalational anesthetic agents were compared. Group I received desflurane (n = 30) and group II isoflurane (n = 30). Both the groups received an initial high flow till equilibration between inspired (Fi) and expired (Fe) agent concentration were achieved, which was defined as Fe/Fi = 0.8. The mean (SD) equilibration time was obtained for both the agent. Then, a drift in end-tidal agent concentration during the minimal flow anesthesia and recovery profile was noted. Results: The mean equilibration time obtained for desflurane and isoflurane were 4.96 ± 1.60 and 16.96 ± 9.64 min (P < 0.001). The drift in end-tidal agent concentration over time was minimal in the desflurane group (P = 0.065). Recovery time was 5.70 ± 2.78 min in the desflurane group and 8.06 ± 31 min in the isoflurane group (P = 0.004). Conclusion: Use of equilibration time of the volatile anesthetic agent as a change-over point, from high flow to minimal flow, can help us use minimal flow anesthesia, in a more efficient way.http://www.joacp.org/article.asp?issn=0970-9185;year=2012;volume=28;issue=4;spage=470;epage=475;aulast=MallikDesfluraneequilibration timefixed timeisofluraneminimal flowvolatile anesthetic agent
collection DOAJ
language English
format Article
sources DOAJ
author Tanuja Mallik
S Aneja
R Tope
V Muralidhar
spellingShingle Tanuja Mallik
S Aneja
R Tope
V Muralidhar
A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
Journal of Anaesthesiology Clinical Pharmacology
Desflurane
equilibration time
fixed time
isoflurane
minimal flow
volatile anesthetic agent
author_facet Tanuja Mallik
S Aneja
R Tope
V Muralidhar
author_sort Tanuja Mallik
title A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
title_short A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
title_full A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
title_fullStr A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
title_full_unstemmed A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
title_sort randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow
publisher Wolters Kluwer Medknow Publications
series Journal of Anaesthesiology Clinical Pharmacology
issn 0970-9185
publishDate 2012-01-01
description Background: In the administration of minimal flow anesthesia, traditionally a fixed time period of high flow has been used before changing over to minimal flow. However, newer studies have used "equilibration time" of a volatile anesthetic agent as the change-over point. Materials and Methods: A randomized prospective study was conducted on 60 patients, who were divided into two groups of 30 patients each. Two volatile inhalational anesthetic agents were compared. Group I received desflurane (n = 30) and group II isoflurane (n = 30). Both the groups received an initial high flow till equilibration between inspired (Fi) and expired (Fe) agent concentration were achieved, which was defined as Fe/Fi = 0.8. The mean (SD) equilibration time was obtained for both the agent. Then, a drift in end-tidal agent concentration during the minimal flow anesthesia and recovery profile was noted. Results: The mean equilibration time obtained for desflurane and isoflurane were 4.96 ± 1.60 and 16.96 ± 9.64 min (P < 0.001). The drift in end-tidal agent concentration over time was minimal in the desflurane group (P = 0.065). Recovery time was 5.70 ± 2.78 min in the desflurane group and 8.06 ± 31 min in the isoflurane group (P = 0.004). Conclusion: Use of equilibration time of the volatile anesthetic agent as a change-over point, from high flow to minimal flow, can help us use minimal flow anesthesia, in a more efficient way.
topic Desflurane
equilibration time
fixed time
isoflurane
minimal flow
volatile anesthetic agent
url http://www.joacp.org/article.asp?issn=0970-9185;year=2012;volume=28;issue=4;spage=470;epage=475;aulast=Mallik
work_keys_str_mv AT tanujamallik arandomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT saneja arandomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT rtope arandomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT vmuralidhar arandomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT tanujamallik randomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT saneja randomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT rtope randomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
AT vmuralidhar randomizedprospectivestudyofdesfluraneversusisofluraneinminimalflowanesthesiausingequilibrationtimeasthechangeoverpointtominimalflow
_version_ 1725664600768118784