Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base
This article details the elements used in the method verification for the simultaneous high performance liquid chromatography (HPLC) assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound base. The method was proven to be linear over 50%–150% of the nomin...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2015-11-01
|
Series: | Chromatography |
Subjects: | |
Online Access: | http://www.mdpi.com/2227-9075/2/4/642 |
id |
doaj-364afe30df2746e6b241f95c22584cf2 |
---|---|
record_format |
Article |
spelling |
doaj-364afe30df2746e6b241f95c22584cf22020-11-25T00:19:35ZengMDPI AGChromatography2227-90752015-11-012464265410.3390/chromatography2040642chromatography2040642Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound BaseTroy Purvis0Humco Compounding, 313 East 12th Street, Suite 230, Austin, TX 78701, USAThis article details the elements used in the method verification for the simultaneous high performance liquid chromatography (HPLC) assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound base. The method was proven to be linear over 50%–150% of the nominal concentration of the standards. The method was proven to be accurate over 50%–150%, with 98%–102% recovery of the actives from spiked placeboes over that range. The method was shown to be specific to the analytes listed and precise, yielding acceptable results for system reproducibility and method repeatability. The method, as written, is considered to have been verified.http://www.mdpi.com/2227-9075/2/4/642PentoxifyllineMupirocinItraconazoleFluticasone Propionatehigh performance liquid chromatography (HPLC)Humco™ Lavare wound base |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Troy Purvis |
spellingShingle |
Troy Purvis Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base Chromatography Pentoxifylline Mupirocin Itraconazole Fluticasone Propionate high performance liquid chromatography (HPLC) Humco™ Lavare wound base |
author_facet |
Troy Purvis |
author_sort |
Troy Purvis |
title |
Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base |
title_short |
Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base |
title_full |
Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base |
title_fullStr |
Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base |
title_full_unstemmed |
Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base |
title_sort |
simultaneous high performance liquid chromatography assay of pentoxifylline, mupirocin, itraconazole, and fluticasone propionate in humco™ lavare wound base |
publisher |
MDPI AG |
series |
Chromatography |
issn |
2227-9075 |
publishDate |
2015-11-01 |
description |
This article details the elements used in the method verification for the simultaneous high performance liquid chromatography (HPLC) assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound base. The method was proven to be linear over 50%–150% of the nominal concentration of the standards. The method was proven to be accurate over 50%–150%, with 98%–102% recovery of the actives from spiked placeboes over that range. The method was shown to be specific to the analytes listed and precise, yielding acceptable results for system reproducibility and method repeatability. The method, as written, is considered to have been verified. |
topic |
Pentoxifylline Mupirocin Itraconazole Fluticasone Propionate high performance liquid chromatography (HPLC) Humco™ Lavare wound base |
url |
http://www.mdpi.com/2227-9075/2/4/642 |
work_keys_str_mv |
AT troypurvis simultaneoushighperformanceliquidchromatographyassayofpentoxifyllinemupirocinitraconazoleandfluticasonepropionateinhumcolavarewoundbase |
_version_ |
1725371029776236544 |