Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks
JUSTIFICATIVA E OBJETIVOS: Desde Bier, é descrita falha de anestesia subaracnóidea que causa desconforto ao paciente e que ocorre, eventualmente, mesmo diante de profissionais hábeis que a tenham conduzido de forma tecnicamente correta. Há variação, no entanto, de conceito de falha e, principalmente...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Anestesiologia
2010-02-01
|
Series: | Revista Brasileira de Anestesiologia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942010000100011 |
id |
doaj-36332c18e12c4d45907f979b4e92dde6 |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hugo Praxedes Antonio Leite Oliva Filho |
spellingShingle |
Hugo Praxedes Antonio Leite Oliva Filho Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks Revista Brasileira de Anestesiologia COMPLICAÇÕES COMPLICAÇÕES TÉCNICAS ANESTÉSICAS, Regional ANESTHETIC TECHNIQUE, Regional COMPLICATIONS COMPLICATIONS |
author_facet |
Hugo Praxedes Antonio Leite Oliva Filho |
author_sort |
Hugo Praxedes |
title |
Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks |
title_short |
Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks |
title_full |
Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks |
title_fullStr |
Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks |
title_full_unstemmed |
Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocks |
title_sort |
falhas na anestesia subaracnóidea fallos en la anestesia subaracnoide failure of subarachnoid blocks |
publisher |
Sociedade Brasileira de Anestesiologia |
series |
Revista Brasileira de Anestesiologia |
issn |
0034-7094 1806-907X |
publishDate |
2010-02-01 |
description |
JUSTIFICATIVA E OBJETIVOS: Desde Bier, é descrita falha de anestesia subaracnóidea que causa desconforto ao paciente e que ocorre, eventualmente, mesmo diante de profissionais hábeis que a tenham conduzido de forma tecnicamente correta. Há variação, no entanto, de conceito de falha e, principalmente, de identificação precisa de causas. O objetivo do trabalho é identificar melhor as causas deste desconforto por meio de revisão sistemática de publicações com casuística significativa. CONTEÚDO: Dividiu-se a análise em três tópicos: anatomia e suas variações; o agente anestésico, que trata da seleção do agente, suas soluções e adições, de forma a atingir o resultado mais apropriado à intervenção cirúrgica proposta; e a dose, discutindo-se concentração, volume ou dose gravimétrica, no sentido de obter resultado mais adequado tanto no que diz respeito à intensidade do bloqueio quanto à sua duração. CONCLUSÕES: As falhas são mais afeitas a fatores técnicos: avaliação anatômica adequada, escolha criteriosa da agulha e do local da punção, cuidados no armazenamento dos agentes, adequação de dose, baricidade, além de posicionamento correto do paciente durante e após punção, tudo adequado ao objetivo cirúrgico.<br>JUSTIFICATIVA Y OBJETIVOS: Bier ya describía los fallos en la anestesia subaracnoidea que causa la incomodidad al paciente, y que se da, eventualmente, incluso con la presencia de profesionales hábiles que la hayan conducido de forma técnicamente correcta. Existe una variación, sin embargo, del concepto de fallo y principalmente, de la identificación precisa de las causas. El objetivo del trabajo es identificar mejor las causas de esa incomodidad a través de la revisión sistemática de publicaciones con casuística significativa. CONTENIDO: El análisis se dividió en tres tópicos: la anatomía y sus variaciones; el agente anestésico, que trata sobre la selección del agente, sus soluciones y añadiduras, para poder alcanzar el resultado más apropiado en la intervención quirúrgica que se propone ejecutar; y la dosis, discutiendo la concentración, el volumen o la dosis gravimétrica, para poder obtener el resultado más adecuado, tanto en lo concerniente a la intensidad del bloqueo, como en lo que respecta a su duración. CONCLUSIONES: Los fallos son más inherentes a los factores técnicos: la evaluación anatómica adecuada, la elección de criterio de la aguja y del local de la punción, los cuidados en el almacenaje de los agentes, la adecuación de la dosis, la baricidad, además del posicionamiento correcto del paciente durante y después de la punción, todo a tono con el objetivo quirúrgico.<br>BACKGROUND AND OBJECTIVES: Due to the discomfort caused to patients, failure of subarachnoid blocks that happen occasionally even when properly conducted be the most capable professionals have been described since Bier. However, the concept of failure and especially identification of the causes vary. The objective of this report was to identify the causes of this discomfort through a systematic review of publications with a significant number of patients. CONTENTS: The analysis was divided in three topics: anatomy and its variations; anesthetic agent, focusing on drug selection, its solutions, and additions to achieve the most appropriate result of the proposed surgery; and the dose, discussing concentration, volume, or gravimetric dose, to obtain the most adequate result regarding the intensity of the blockade and its duration. CONCLUSIONS: Failures are more commonly secondary to technical factors: adequate anatomic assessment, judicious choice of the needle and puncture site, care when storing the drugs, dose adequacy, and baricity, besides proper patient positioning during and after the puncture, and they all should be adequate for the surgical objective. |
topic |
COMPLICAÇÕES COMPLICAÇÕES TÉCNICAS ANESTÉSICAS, Regional ANESTHETIC TECHNIQUE, Regional COMPLICATIONS COMPLICATIONS |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942010000100011 |
work_keys_str_mv |
AT hugopraxedes falhasnaanestesiasubaracnoideafallosenlaanestesiasubaracnoidefailureofsubarachnoidblocks AT antonioleiteolivafilho falhasnaanestesiasubaracnoideafallosenlaanestesiasubaracnoidefailureofsubarachnoidblocks |
_version_ |
1716822666646650880 |
spelling |
doaj-36332c18e12c4d45907f979b4e92dde62020-11-24T20:42:17ZengSociedade Brasileira de AnestesiologiaRevista Brasileira de Anestesiologia0034-70941806-907X2010-02-01601909710.1590/S0034-70942010000100011Falhas na anestesia subaracnóidea Fallos en la anestesia subaracnoide Failure of subarachnoid blocksHugo PraxedesAntonio Leite Oliva FilhoJUSTIFICATIVA E OBJETIVOS: Desde Bier, é descrita falha de anestesia subaracnóidea que causa desconforto ao paciente e que ocorre, eventualmente, mesmo diante de profissionais hábeis que a tenham conduzido de forma tecnicamente correta. Há variação, no entanto, de conceito de falha e, principalmente, de identificação precisa de causas. O objetivo do trabalho é identificar melhor as causas deste desconforto por meio de revisão sistemática de publicações com casuística significativa. CONTEÚDO: Dividiu-se a análise em três tópicos: anatomia e suas variações; o agente anestésico, que trata da seleção do agente, suas soluções e adições, de forma a atingir o resultado mais apropriado à intervenção cirúrgica proposta; e a dose, discutindo-se concentração, volume ou dose gravimétrica, no sentido de obter resultado mais adequado tanto no que diz respeito à intensidade do bloqueio quanto à sua duração. CONCLUSÕES: As falhas são mais afeitas a fatores técnicos: avaliação anatômica adequada, escolha criteriosa da agulha e do local da punção, cuidados no armazenamento dos agentes, adequação de dose, baricidade, além de posicionamento correto do paciente durante e após punção, tudo adequado ao objetivo cirúrgico.<br>JUSTIFICATIVA Y OBJETIVOS: Bier ya describía los fallos en la anestesia subaracnoidea que causa la incomodidad al paciente, y que se da, eventualmente, incluso con la presencia de profesionales hábiles que la hayan conducido de forma técnicamente correcta. Existe una variación, sin embargo, del concepto de fallo y principalmente, de la identificación precisa de las causas. El objetivo del trabajo es identificar mejor las causas de esa incomodidad a través de la revisión sistemática de publicaciones con casuística significativa. CONTENIDO: El análisis se dividió en tres tópicos: la anatomía y sus variaciones; el agente anestésico, que trata sobre la selección del agente, sus soluciones y añadiduras, para poder alcanzar el resultado más apropiado en la intervención quirúrgica que se propone ejecutar; y la dosis, discutiendo la concentración, el volumen o la dosis gravimétrica, para poder obtener el resultado más adecuado, tanto en lo concerniente a la intensidad del bloqueo, como en lo que respecta a su duración. CONCLUSIONES: Los fallos son más inherentes a los factores técnicos: la evaluación anatómica adecuada, la elección de criterio de la aguja y del local de la punción, los cuidados en el almacenaje de los agentes, la adecuación de la dosis, la baricidad, además del posicionamiento correcto del paciente durante y después de la punción, todo a tono con el objetivo quirúrgico.<br>BACKGROUND AND OBJECTIVES: Due to the discomfort caused to patients, failure of subarachnoid blocks that happen occasionally even when properly conducted be the most capable professionals have been described since Bier. However, the concept of failure and especially identification of the causes vary. The objective of this report was to identify the causes of this discomfort through a systematic review of publications with a significant number of patients. CONTENTS: The analysis was divided in three topics: anatomy and its variations; anesthetic agent, focusing on drug selection, its solutions, and additions to achieve the most appropriate result of the proposed surgery; and the dose, discussing concentration, volume, or gravimetric dose, to obtain the most adequate result regarding the intensity of the blockade and its duration. CONCLUSIONS: Failures are more commonly secondary to technical factors: adequate anatomic assessment, judicious choice of the needle and puncture site, care when storing the drugs, dose adequacy, and baricity, besides proper patient positioning during and after the puncture, and they all should be adequate for the surgical objective.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942010000100011COMPLICAÇÕESCOMPLICAÇÕESTÉCNICAS ANESTÉSICAS, RegionalANESTHETIC TECHNIQUE, RegionalCOMPLICATIONSCOMPLICATIONS |