Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity
Laser-deposited gold immobilization layers having different porosities were incorporated into love wave surface acoustic wave sensors (LW-SAWs). Variation of pulsed laser deposition parameters allows good control of the gold film morphology. Biosensors with various gold film porosities were tested u...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-07-01
|
Series: | Chemosensors |
Subjects: | |
Online Access: | https://www.mdpi.com/2227-9040/9/7/173 |
id |
doaj-361d256d3c80456fa32e0db75a1548cc |
---|---|
record_format |
Article |
spelling |
doaj-361d256d3c80456fa32e0db75a1548cc2021-07-23T13:35:28ZengMDPI AGChemosensors2227-90402021-07-01917317310.3390/chemosensors9070173Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled PorosityDana Miu0Izabela Constantinoiu1Valentina Dinca2Cristian Viespe3Laser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, RomaniaLaser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, RomaniaLaser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, RomaniaLaser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, RomaniaLaser-deposited gold immobilization layers having different porosities were incorporated into love wave surface acoustic wave sensors (LW-SAWs). Variation of pulsed laser deposition parameters allows good control of the gold film morphology. Biosensors with various gold film porosities were tested using the biotin–avidin reaction. Control of the Au layer morphology is important since the biotin and avidin layer morphologies closely follow that of the gold. The response of the sensors to biotin/avidin, which is a good indicator of biosensor performance, is improved when the gold layer has increased porosity. Given the sizes of the proteins, the laser-deposited porous gold interfaces have optimal pore dimensions to ensure protein stability.https://www.mdpi.com/2227-9040/9/7/173SAW sensorpulsed laser depositionbiosensorAunanoporous filmlove wave |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dana Miu Izabela Constantinoiu Valentina Dinca Cristian Viespe |
spellingShingle |
Dana Miu Izabela Constantinoiu Valentina Dinca Cristian Viespe Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity Chemosensors SAW sensor pulsed laser deposition biosensor Au nanoporous film love wave |
author_facet |
Dana Miu Izabela Constantinoiu Valentina Dinca Cristian Viespe |
author_sort |
Dana Miu |
title |
Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity |
title_short |
Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity |
title_full |
Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity |
title_fullStr |
Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity |
title_full_unstemmed |
Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity |
title_sort |
surface acoustic wave biosensor with laser-deposited gold layer having controlled porosity |
publisher |
MDPI AG |
series |
Chemosensors |
issn |
2227-9040 |
publishDate |
2021-07-01 |
description |
Laser-deposited gold immobilization layers having different porosities were incorporated into love wave surface acoustic wave sensors (LW-SAWs). Variation of pulsed laser deposition parameters allows good control of the gold film morphology. Biosensors with various gold film porosities were tested using the biotin–avidin reaction. Control of the Au layer morphology is important since the biotin and avidin layer morphologies closely follow that of the gold. The response of the sensors to biotin/avidin, which is a good indicator of biosensor performance, is improved when the gold layer has increased porosity. Given the sizes of the proteins, the laser-deposited porous gold interfaces have optimal pore dimensions to ensure protein stability. |
topic |
SAW sensor pulsed laser deposition biosensor Au nanoporous film love wave |
url |
https://www.mdpi.com/2227-9040/9/7/173 |
work_keys_str_mv |
AT danamiu surfaceacousticwavebiosensorwithlaserdepositedgoldlayerhavingcontrolledporosity AT izabelaconstantinoiu surfaceacousticwavebiosensorwithlaserdepositedgoldlayerhavingcontrolledporosity AT valentinadinca surfaceacousticwavebiosensorwithlaserdepositedgoldlayerhavingcontrolledporosity AT cristianviespe surfaceacousticwavebiosensorwithlaserdepositedgoldlayerhavingcontrolledporosity |
_version_ |
1721288868131504128 |