A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements
A new bio-imaging method has been developed by introducing an experimental verification of capacitively coupled resistivity imaging in a small scale. This paper focuses on the 2D circular array imaging sensor as well as a 3D planar array imaging sensor with spectroscopic measurements in a wide range...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-06-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/11/3327 |
id |
doaj-35f4e8aa377b4be4afdde476947503ca |
---|---|
record_format |
Article |
spelling |
doaj-35f4e8aa377b4be4afdde476947503ca2020-11-25T03:17:06ZengMDPI AGSensors1424-82202020-06-01203327332710.3390/s20113327A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy MeasurementsGege Ma0Manuchehr Soleimani1Engineering Tomography Laboratory (ETL), Department of Electronic and Electrical Engineering, University of Bath, Bath BA2 7AY, UKEngineering Tomography Laboratory (ETL), Department of Electronic and Electrical Engineering, University of Bath, Bath BA2 7AY, UKA new bio-imaging method has been developed by introducing an experimental verification of capacitively coupled resistivity imaging in a small scale. This paper focuses on the 2D circular array imaging sensor as well as a 3D planar array imaging sensor with spectroscopic measurements in a wide range from low frequency to radiofrequency. Both these two setups are well suited for standard containers used in cell and culture biological studies, allowing for fully non-invasive testing. This is true as the capacitive based imaging sensor can extract dielectric spectroscopic images from the sample without direct contact with the medium. The paper shows the concept by deriving a wide range of spectroscopic information from biological test samples. We drive both spectra of electrical conductivity and the change rate of electrical conductivity with frequency as a piece of fundamentally important information. The high-frequency excitation allows the interrogation of critical properties that arise from the cell nucleus.https://www.mdpi.com/1424-8220/20/11/3327cell and cell tissue imagingminiaturized tomographycapacitively-coupled electrical resistivity tomography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gege Ma Manuchehr Soleimani |
spellingShingle |
Gege Ma Manuchehr Soleimani A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements Sensors cell and cell tissue imaging miniaturized tomography capacitively-coupled electrical resistivity tomography |
author_facet |
Gege Ma Manuchehr Soleimani |
author_sort |
Gege Ma |
title |
A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements |
title_short |
A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements |
title_full |
A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements |
title_fullStr |
A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements |
title_full_unstemmed |
A New Label-Free and Contactless Bio-Tomographic Imaging with Miniaturized Capacitively-Coupled Spectroscopy Measurements |
title_sort |
new label-free and contactless bio-tomographic imaging with miniaturized capacitively-coupled spectroscopy measurements |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2020-06-01 |
description |
A new bio-imaging method has been developed by introducing an experimental verification of capacitively coupled resistivity imaging in a small scale. This paper focuses on the 2D circular array imaging sensor as well as a 3D planar array imaging sensor with spectroscopic measurements in a wide range from low frequency to radiofrequency. Both these two setups are well suited for standard containers used in cell and culture biological studies, allowing for fully non-invasive testing. This is true as the capacitive based imaging sensor can extract dielectric spectroscopic images from the sample without direct contact with the medium. The paper shows the concept by deriving a wide range of spectroscopic information from biological test samples. We drive both spectra of electrical conductivity and the change rate of electrical conductivity with frequency as a piece of fundamentally important information. The high-frequency excitation allows the interrogation of critical properties that arise from the cell nucleus. |
topic |
cell and cell tissue imaging miniaturized tomography capacitively-coupled electrical resistivity tomography |
url |
https://www.mdpi.com/1424-8220/20/11/3327 |
work_keys_str_mv |
AT gegema anewlabelfreeandcontactlessbiotomographicimagingwithminiaturizedcapacitivelycoupledspectroscopymeasurements AT manuchehrsoleimani anewlabelfreeandcontactlessbiotomographicimagingwithminiaturizedcapacitivelycoupledspectroscopymeasurements AT gegema newlabelfreeandcontactlessbiotomographicimagingwithminiaturizedcapacitivelycoupledspectroscopymeasurements AT manuchehrsoleimani newlabelfreeandcontactlessbiotomographicimagingwithminiaturizedcapacitivelycoupledspectroscopymeasurements |
_version_ |
1724633330763169792 |