Factors that influence the stability of the FDG
Introduction – The absence of a cyclotron for production of 2-[18F]Fluor-2- -deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of i...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Escola Superior de Tecnologia da Saúde de Lisboa
2015-11-01
|
Series: | Saúde & Tecnologia |
Subjects: | |
Online Access: | https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/354 |
id |
doaj-35c6a281846a4d6abf2825fb852dc644 |
---|---|
record_format |
Article |
spelling |
doaj-35c6a281846a4d6abf2825fb852dc6442020-11-24T22:19:35ZengEscola Superior de Tecnologia da Saúde de LisboaSaúde & Tecnologia1646-97042015-11-0105353810.25758/s&t.v0i5.354364Factors that influence the stability of the FDGAna Graça0Román Sánchez Sánchez1Luda Grada Bernardo2Juan Rayo Madrid3Filipa Lucena4Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de LisboaServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozÁrea Científica de Medicina Nuclear, Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de LisboaIntroduction – The absence of a cyclotron for production of 2-[18F]Fluor-2- -deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of its synthesis till the administration to the patient. The purpose of this study is to show the influence of the parameters temperature, pH, radioactive concentration (CR) and time in radiochemical purity. Methodology – We analyzed the pH and the radiochemical purity [by thin layer chromatography (TLC)] of six samples of 18F-FDG with different CR and at different times and temperatures. Results – There was an increase in the percentage of 18F with time. Nevertheless, results show that samples’ dilution decreases the degradation of 18F-FDG. However, comparing only the diluted samples (185 and 740 MBq / ml), there is a positive relationship between CR and the percentage of 18F-. There was also an increase in percentage of 18F at higher temperatures. Conclusion – We advise to dilute the solution and the period of time for storage the 18F-FDG should not be so long. The samples must have a stable temperature and pH.https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/35418F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ana Graça Román Sánchez Sánchez Luda Grada Bernardo Juan Rayo Madrid Filipa Lucena |
spellingShingle |
Ana Graça Román Sánchez Sánchez Luda Grada Bernardo Juan Rayo Madrid Filipa Lucena Factors that influence the stability of the FDG Saúde & Tecnologia 18F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F |
author_facet |
Ana Graça Román Sánchez Sánchez Luda Grada Bernardo Juan Rayo Madrid Filipa Lucena |
author_sort |
Ana Graça |
title |
Factors that influence the stability of the FDG |
title_short |
Factors that influence the stability of the FDG |
title_full |
Factors that influence the stability of the FDG |
title_fullStr |
Factors that influence the stability of the FDG |
title_full_unstemmed |
Factors that influence the stability of the FDG |
title_sort |
factors that influence the stability of the fdg |
publisher |
Escola Superior de Tecnologia da Saúde de Lisboa |
series |
Saúde & Tecnologia |
issn |
1646-9704 |
publishDate |
2015-11-01 |
description |
Introduction – The absence of a cyclotron for production of 2-[18F]Fluor-2-
-deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of its synthesis till the administration to the patient. The purpose of this study is to show the influence of the parameters temperature, pH, radioactive concentration (CR) and time in radiochemical purity. Methodology – We analyzed the pH and the radiochemical purity [by thin layer chromatography (TLC)] of six samples of 18F-FDG with different CR and at different times and temperatures. Results – There was an increase in the percentage of 18F with time. Nevertheless, results show that samples’ dilution decreases the degradation of 18F-FDG. However, comparing only the diluted samples (185 and 740 MBq / ml), there is a positive relationship between CR and the percentage of 18F-. There was also an increase in percentage of 18F at higher temperatures. Conclusion – We advise to dilute the solution and the period of time for storage the 18F-FDG should not be so long. The samples must have a stable temperature and pH. |
topic |
18F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F |
url |
https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/354 |
work_keys_str_mv |
AT anagraca factorsthatinfluencethestabilityofthefdg AT romansanchezsanchez factorsthatinfluencethestabilityofthefdg AT ludagradabernardo factorsthatinfluencethestabilityofthefdg AT juanrayomadrid factorsthatinfluencethestabilityofthefdg AT filipalucena factorsthatinfluencethestabilityofthefdg |
_version_ |
1725778365323935744 |