Factors that influence the stability of the FDG

Introduction – The absence of a cyclotron for production of 2-[18F]Fluor-2- -deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of i...

Full description

Bibliographic Details
Main Authors: Ana Graça, Román Sánchez Sánchez, Luda Grada Bernardo, Juan Rayo Madrid, Filipa Lucena
Format: Article
Language:English
Published: Escola Superior de Tecnologia da Saúde de Lisboa 2015-11-01
Series:Saúde & Tecnologia
Subjects:
Online Access:https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/354
id doaj-35c6a281846a4d6abf2825fb852dc644
record_format Article
spelling doaj-35c6a281846a4d6abf2825fb852dc6442020-11-24T22:19:35ZengEscola Superior de Tecnologia da Saúde de LisboaSaúde & Tecnologia1646-97042015-11-0105353810.25758/s&t.v0i5.354364Factors that influence the stability of the FDGAna Graça0Román Sánchez Sánchez1Luda Grada Bernardo2Juan Rayo Madrid3Filipa Lucena4Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de LisboaServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozServiço de Medicina Nuclear, Hospital Infanta Cristina, BadajozÁrea Científica de Medicina Nuclear, Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de LisboaIntroduction – The absence of a cyclotron for production of 2-[18F]Fluor-2- -deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of its synthesis till the administration to the patient. The purpose of this study is to show the influence of the parameters temperature, pH, radioactive concentration (CR) and time in radiochemical purity. Methodology – We analyzed the pH and the radiochemical purity [by thin layer chromatography (TLC)] of six samples of 18F-FDG with different CR and at different times and temperatures. Results – There was an increase in the percentage of 18F with time. Nevertheless, results show that samples’ dilution decreases the degradation of 18F-FDG. However, comparing only the diluted samples (185 and 740 MBq / ml), there is a positive relationship between CR and the percentage of 18F-. There was also an increase in percentage of 18F at higher temperatures. Conclusion – We advise to dilute the solution and the period of time for storage the 18F-FDG should not be so long. The samples must have a stable temperature and pH.https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/35418F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F
collection DOAJ
language English
format Article
sources DOAJ
author Ana Graça
Román Sánchez Sánchez
Luda Grada Bernardo
Juan Rayo Madrid
Filipa Lucena
spellingShingle Ana Graça
Román Sánchez Sánchez
Luda Grada Bernardo
Juan Rayo Madrid
Filipa Lucena
Factors that influence the stability of the FDG
Saúde & Tecnologia
18F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F
author_facet Ana Graça
Román Sánchez Sánchez
Luda Grada Bernardo
Juan Rayo Madrid
Filipa Lucena
author_sort Ana Graça
title Factors that influence the stability of the FDG
title_short Factors that influence the stability of the FDG
title_full Factors that influence the stability of the FDG
title_fullStr Factors that influence the stability of the FDG
title_full_unstemmed Factors that influence the stability of the FDG
title_sort factors that influence the stability of the fdg
publisher Escola Superior de Tecnologia da Saúde de Lisboa
series Saúde & Tecnologia
issn 1646-9704
publishDate 2015-11-01
description Introduction – The absence of a cyclotron for production of 2-[18F]Fluor-2- -deoxy-D-glucose (18F-FDG) is now a reality for most of the centers where Positron Emission Tomography (TEP) exams are held in. It is therefore important to ensure the quality of this radiopharmaceutical from the moment of its synthesis till the administration to the patient. The purpose of this study is to show the influence of the parameters temperature, pH, radioactive concentration (CR) and time in radiochemical purity. Methodology – We analyzed the pH and the radiochemical purity [by thin layer chromatography (TLC)] of six samples of 18F-FDG with different CR and at different times and temperatures. Results – There was an increase in the percentage of 18F with time. Nevertheless, results show that samples’ dilution decreases the degradation of 18F-FDG. However, comparing only the diluted samples (185 and 740 MBq / ml), there is a positive relationship between CR and the percentage of 18F-. There was also an increase in percentage of 18F at higher temperatures. Conclusion – We advise to dilute the solution and the period of time for storage the 18F-FDG should not be so long. The samples must have a stable temperature and pH.
topic 18F-FDG, pureza radioquímica, autoradiólise, percentagem de 18F
url https://web.estesl.ipl.pt/ojs/index.php/ST/article/view/354
work_keys_str_mv AT anagraca factorsthatinfluencethestabilityofthefdg
AT romansanchezsanchez factorsthatinfluencethestabilityofthefdg
AT ludagradabernardo factorsthatinfluencethestabilityofthefdg
AT juanrayomadrid factorsthatinfluencethestabilityofthefdg
AT filipalucena factorsthatinfluencethestabilityofthefdg
_version_ 1725778365323935744