Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate

Humidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system...

Full description

Bibliographic Details
Main Authors: Jerzy Sowa, Maciej Mijakowski
Format: Article
Language:English
Published: MDPI AG 2020-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/24/6669
id doaj-35b3da8c0a6d47729b423c7856e5d718
record_format Article
spelling doaj-35b3da8c0a6d47729b423c7856e5d7182020-12-18T00:02:51ZengMDPI AGEnergies1996-10732020-12-01136669666910.3390/en13246669Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental ClimateJerzy Sowa0Maciej Mijakowski1Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, PolandFaculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, PolandHumidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system when applied in an eight-floor, multiunit, residential building, i.e., the virtual reference building described by the National Energy Conservation Agency (NAPE), Poland. Simulations using the computer program CONTAM were performed for the whole heating season based upon the climate in Warsaw. Besides passive stack ventilation, that served as a reference, two ventilation systems were studied: one standard and one “hybrid” system with additional roof fans. This study confirmed that the application of humidity-sensitive, demand-controlled ventilation in multiunit residential buildings in a continental climate (Dfb) led to significant energy savings (up to 11.64 kWh/m<sup>2</sup> of primary energy). However, the operation of the system on higher floors was found to be ineffective. Ensuring consistent operation of the system on all floors required supplementary fans. The introduction of a hybrid mode reduced carbon dioxide concentrations by approximately 32% in the units located in the upper part of the building. The energetic effect in such cases depends strongly on the electricity source. In the case of the national energy grid, savings of primary energy would be relatively low, i.e., 1.07 kWh/m<sup>2</sup>, but in the case of locally produced renewable energy, the energy savings would be equal to 5.18 kWh/m<sup>2</sup>.https://www.mdpi.com/1996-1073/13/24/6669energy usedemand-controlled ventilationhybrid ventilationhumiditymultiunit residential buildingsimulation
collection DOAJ
language English
format Article
sources DOAJ
author Jerzy Sowa
Maciej Mijakowski
spellingShingle Jerzy Sowa
Maciej Mijakowski
Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
Energies
energy use
demand-controlled ventilation
hybrid ventilation
humidity
multiunit residential building
simulation
author_facet Jerzy Sowa
Maciej Mijakowski
author_sort Jerzy Sowa
title Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
title_short Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
title_full Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
title_fullStr Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
title_full_unstemmed Humidity-Sensitive, Demand-Controlled Ventilation Applied to Multiunit Residential Building—Performance and Energy Consumption in Dfb Continental Climate
title_sort humidity-sensitive, demand-controlled ventilation applied to multiunit residential building—performance and energy consumption in dfb continental climate
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2020-12-01
description Humidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system when applied in an eight-floor, multiunit, residential building, i.e., the virtual reference building described by the National Energy Conservation Agency (NAPE), Poland. Simulations using the computer program CONTAM were performed for the whole heating season based upon the climate in Warsaw. Besides passive stack ventilation, that served as a reference, two ventilation systems were studied: one standard and one “hybrid” system with additional roof fans. This study confirmed that the application of humidity-sensitive, demand-controlled ventilation in multiunit residential buildings in a continental climate (Dfb) led to significant energy savings (up to 11.64 kWh/m<sup>2</sup> of primary energy). However, the operation of the system on higher floors was found to be ineffective. Ensuring consistent operation of the system on all floors required supplementary fans. The introduction of a hybrid mode reduced carbon dioxide concentrations by approximately 32% in the units located in the upper part of the building. The energetic effect in such cases depends strongly on the electricity source. In the case of the national energy grid, savings of primary energy would be relatively low, i.e., 1.07 kWh/m<sup>2</sup>, but in the case of locally produced renewable energy, the energy savings would be equal to 5.18 kWh/m<sup>2</sup>.
topic energy use
demand-controlled ventilation
hybrid ventilation
humidity
multiunit residential building
simulation
url https://www.mdpi.com/1996-1073/13/24/6669
work_keys_str_mv AT jerzysowa humiditysensitivedemandcontrolledventilationappliedtomultiunitresidentialbuildingperformanceandenergyconsumptionindfbcontinentalclimate
AT maciejmijakowski humiditysensitivedemandcontrolledventilationappliedtomultiunitresidentialbuildingperformanceandenergyconsumptionindfbcontinentalclimate
_version_ 1724378855459782656