A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study
Aim: The aim of this study was to compare and evaluate the efficacy of ViscoStat clear, Vasozine, and Racegel (with and without cord) with respect to the amount of lateral gingival displacement produced by them. Settings and Design: Comparative - In vivo study. Material and Methods: Thirty consented...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2019-01-01
|
Series: | The Journal of Indian Prosthodontic Society |
Subjects: | |
Online Access: | http://www.j-ips.org/article.asp?issn=0972-4052;year=2019;volume=19;issue=4;spage=313;epage=323;aulast=Kesari |
id |
doaj-3576def676e5420c9e5046be9b8e7dfe |
---|---|
record_format |
Article |
spelling |
doaj-3576def676e5420c9e5046be9b8e7dfe2020-11-25T02:05:57ZengWolters Kluwer Medknow PublicationsThe Journal of Indian Prosthodontic Society0972-40521998-40572019-01-0119431332310.4103/jips.jips_288_19A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo studyZainab Ilyas KesariJyoti Tipin KaraniSaloni Sharad MistryAshutosh Ramesh PaiAim: The aim of this study was to compare and evaluate the efficacy of ViscoStat clear, Vasozine, and Racegel (with and without cord) with respect to the amount of lateral gingival displacement produced by them. Settings and Design: Comparative - In vivo study. Material and Methods: Thirty consented volunteers were selected in the age group of 18–22 years. Maxillary right first premolar and lateral incisor and maxillary left central incisor and canine were selected for each individual. A composite resin standard reference point was made two millimeters below the gingival margin on the midsection of the labial surface of each tooth. By simple random sampling, the agents (ViscoStat clear, Vasozine, and Racegel with cord and Racegel without cord) were used for gingival displacement on each of the selected teeth. Pre- and postgingival displacement impressions were made with medium-body polyvinyl siloxane impression material. Three-millimeter thick buccolingual slice sections were obtained of the models and measured under a stereo microscope (×20 magnification), and the amount of displacement was calculated. Statistical Analysis used: The Kruskal–Wallis test and the Mann–Whitney U-test were used for comparison between the amounts of gingival displacement produced by them. Results: Mean displacement produced (in mm2) by Racegel with cord, tetrahydrozoline, ViscoStat clear, and Racegel is 0.2256, 0.2158, 0.2069, and 0.1414, respectively. Conclusions: The largest mean gingival displacement was produced by Racegel with cord (0.2256 mm2) and lowest by Racegel without cord (0.1414 mm2). There was no significant statistical difference in the amount of gingival displacement produced between the four agents.http://www.j-ips.org/article.asp?issn=0972-4052;year=2019;volume=19;issue=4;spage=313;epage=323;aulast=KesariGingival displacementmarginal integrityRacegeltetrahydrozolineUltrapak cordViscoStat clear |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zainab Ilyas Kesari Jyoti Tipin Karani Saloni Sharad Mistry Ashutosh Ramesh Pai |
spellingShingle |
Zainab Ilyas Kesari Jyoti Tipin Karani Saloni Sharad Mistry Ashutosh Ramesh Pai A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study The Journal of Indian Prosthodontic Society Gingival displacement marginal integrity Racegel tetrahydrozoline Ultrapak cord ViscoStat clear |
author_facet |
Zainab Ilyas Kesari Jyoti Tipin Karani Saloni Sharad Mistry Ashutosh Ramesh Pai |
author_sort |
Zainab Ilyas Kesari |
title |
A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study |
title_short |
A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study |
title_full |
A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study |
title_fullStr |
A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study |
title_full_unstemmed |
A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – Anin vivo study |
title_sort |
comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents – anin vivo study |
publisher |
Wolters Kluwer Medknow Publications |
series |
The Journal of Indian Prosthodontic Society |
issn |
0972-4052 1998-4057 |
publishDate |
2019-01-01 |
description |
Aim: The aim of this study was to compare and evaluate the efficacy of ViscoStat clear, Vasozine, and Racegel (with and without cord) with respect to the amount of lateral gingival displacement produced by them.
Settings and Design: Comparative - In vivo study.
Material and Methods: Thirty consented volunteers were selected in the age group of 18–22 years. Maxillary right first premolar and lateral incisor and maxillary left central incisor and canine were selected for each individual. A composite resin standard reference point was made two millimeters below the gingival margin on the midsection of the labial surface of each tooth. By simple random sampling, the agents (ViscoStat clear, Vasozine, and Racegel with cord and Racegel without cord) were used for gingival displacement on each of the selected teeth. Pre- and postgingival displacement impressions were made with medium-body polyvinyl siloxane impression material. Three-millimeter thick buccolingual slice sections were obtained of the models and measured under a stereo microscope (×20 magnification), and the amount of displacement was calculated.
Statistical Analysis used: The Kruskal–Wallis test and the Mann–Whitney U-test were used for comparison between the amounts of gingival displacement produced by them.
Results: Mean displacement produced (in mm2) by Racegel with cord, tetrahydrozoline, ViscoStat clear, and Racegel is 0.2256, 0.2158, 0.2069, and 0.1414, respectively.
Conclusions: The largest mean gingival displacement was produced by Racegel with cord (0.2256 mm2) and lowest by Racegel without cord (0.1414 mm2). There was no significant statistical difference in the amount of gingival displacement produced between the four agents. |
topic |
Gingival displacement marginal integrity Racegel tetrahydrozoline Ultrapak cord ViscoStat clear |
url |
http://www.j-ips.org/article.asp?issn=0972-4052;year=2019;volume=19;issue=4;spage=313;epage=323;aulast=Kesari |
work_keys_str_mv |
AT zainabilyaskesari acomparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT jyotitipinkarani acomparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT salonisharadmistry acomparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT ashutoshrameshpai acomparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT zainabilyaskesari comparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT jyotitipinkarani comparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT salonisharadmistry comparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy AT ashutoshrameshpai comparativeevaluationofamountofgingivaldisplacementproducedbyfourdifferentgingivaldisplacementagentsaninvivostudy |
_version_ |
1724935884898304000 |