Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis

Background and Aims: The preterm and ex-preterm babies form a separate group among the paediatric population with unique airway anatomy. The utility of C-MAC® Video laryngoscope (VL) for routine intubation of preterm babies has not been evaluated. The purpose of this study is to report the performan...

Full description

Bibliographic Details
Main Authors: Renu Sinha, Kanil Ranjith Kumar, Ram Kumar Kalaiyarasan, Puneet Khanna, Bikash Ranjan Ray, Ravinder Kumar Pandey, Jyotsna Punj, Vanlal Darlong
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Indian Journal of Anaesthesia
Subjects:
Online Access:http://www.ijaweb.org/article.asp?issn=0019-5049;year=2019;volume=63;issue=4;spage=284;epage=288;aulast=Sinha
id doaj-34a5f3fa1fea4cbf8ef534afd719fa3c
record_format Article
spelling doaj-34a5f3fa1fea4cbf8ef534afd719fa3c2020-11-24T21:45:49ZengWolters Kluwer Medknow PublicationsIndian Journal of Anaesthesia0019-50490976-28172019-01-0163428428810.4103/ija.IJA_753_18Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysisRenu SinhaKanil Ranjith KumarRam Kumar KalaiyarasanPuneet KhannaBikash Ranjan RayRavinder Kumar PandeyJyotsna PunjVanlal DarlongBackground and Aims: The preterm and ex-preterm babies form a separate group among the paediatric population with unique airway anatomy. The utility of C-MAC® Video laryngoscope (VL) for routine intubation of preterm babies has not been evaluated. The purpose of this study is to report the performance of C-MAC® VL Miller blade size-0 for endotracheal intubation in preterm babies at our institute. Methods: After Institute Ethics Committee approval, a retrospective study was designed to evaluate the performance of C-MAC® VL for intubation in preterm and ex-preterm babies. The medical files, and video recordings of preterm babies up to 60 weeks of post-gestational age who had undergone surgery for retinopathy of prematurity from January 2014 to April 2016 were reviewed. All babies were intubated with C-MAC® Miller blade size-0. Demographic parameters, time to best glottic view (TTGV), time to intubate (TTI), ease and number of intubation attempts were assessed. Episodes of desaturation and complications related to intubation were recorded. Results: Data of 37 preterm and ex-preterm babies were analysed. The mean age and weight at the time of surgery were 40.5 (±4.9) weeks and 2532 (±879) grams respectively. The median TTGV and TTI were 11.0 and 22.0 seconds. A total of 32 babies (86.5%) were intubated on initial attempt and five were intubated on second attempt. Stylet was used to facilitate intubation in all infants. There was no incidence of desaturation, mucosal injury or bleeding. Conclusion: C-MAC video laryngoscope Miller blade size 0 is suitable for endotracheal intubation in preterm and ex-preterm infants.http://www.ijaweb.org/article.asp?issn=0019-5049;year=2019;volume=63;issue=4;spage=284;epage=288;aulast=SinhaAirwaydeviceslaryngoscopesneonate
collection DOAJ
language English
format Article
sources DOAJ
author Renu Sinha
Kanil Ranjith Kumar
Ram Kumar Kalaiyarasan
Puneet Khanna
Bikash Ranjan Ray
Ravinder Kumar Pandey
Jyotsna Punj
Vanlal Darlong
spellingShingle Renu Sinha
Kanil Ranjith Kumar
Ram Kumar Kalaiyarasan
Puneet Khanna
Bikash Ranjan Ray
Ravinder Kumar Pandey
Jyotsna Punj
Vanlal Darlong
Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
Indian Journal of Anaesthesia
Airway
devices
laryngoscopes
neonate
author_facet Renu Sinha
Kanil Ranjith Kumar
Ram Kumar Kalaiyarasan
Puneet Khanna
Bikash Ranjan Ray
Ravinder Kumar Pandey
Jyotsna Punj
Vanlal Darlong
author_sort Renu Sinha
title Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
title_short Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
title_full Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
title_fullStr Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
title_full_unstemmed Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
title_sort evaluation of performance of c-mac® video laryngoscope miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: a retrospective analysis
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Anaesthesia
issn 0019-5049
0976-2817
publishDate 2019-01-01
description Background and Aims: The preterm and ex-preterm babies form a separate group among the paediatric population with unique airway anatomy. The utility of C-MAC® Video laryngoscope (VL) for routine intubation of preterm babies has not been evaluated. The purpose of this study is to report the performance of C-MAC® VL Miller blade size-0 for endotracheal intubation in preterm babies at our institute. Methods: After Institute Ethics Committee approval, a retrospective study was designed to evaluate the performance of C-MAC® VL for intubation in preterm and ex-preterm babies. The medical files, and video recordings of preterm babies up to 60 weeks of post-gestational age who had undergone surgery for retinopathy of prematurity from January 2014 to April 2016 were reviewed. All babies were intubated with C-MAC® Miller blade size-0. Demographic parameters, time to best glottic view (TTGV), time to intubate (TTI), ease and number of intubation attempts were assessed. Episodes of desaturation and complications related to intubation were recorded. Results: Data of 37 preterm and ex-preterm babies were analysed. The mean age and weight at the time of surgery were 40.5 (±4.9) weeks and 2532 (±879) grams respectively. The median TTGV and TTI were 11.0 and 22.0 seconds. A total of 32 babies (86.5%) were intubated on initial attempt and five were intubated on second attempt. Stylet was used to facilitate intubation in all infants. There was no incidence of desaturation, mucosal injury or bleeding. Conclusion: C-MAC video laryngoscope Miller blade size 0 is suitable for endotracheal intubation in preterm and ex-preterm infants.
topic Airway
devices
laryngoscopes
neonate
url http://www.ijaweb.org/article.asp?issn=0019-5049;year=2019;volume=63;issue=4;spage=284;epage=288;aulast=Sinha
work_keys_str_mv AT renusinha evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT kanilranjithkumar evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT ramkumarkalaiyarasan evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT puneetkhanna evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT bikashranjanray evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT ravinderkumarpandey evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT jyotsnapunj evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
AT vanlaldarlong evaluationofperformanceofcmacvideolaryngoscopemillerbladesizezeroforendotrachealintubationinpretermandexpreterminfantsaretrospectiveanalysis
_version_ 1725904016504782848