An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)

Leakage of electromagnetic fields (EMF) from short-wave radiofrequency physiotherapeutic diathermies (SWDs) may cause health and safety hazards affecting unintentionally exposed workers (W) or general public (GP) members (assisting patient exposed during treatment or presenting there for other reaso...

Full description

Bibliographic Details
Main Authors: Jolanta Karpowicz, Krzysztof Gryz
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:BioMed Research International
Online Access:http://dx.doi.org/10.1155/2013/150143
id doaj-34686865a0a24d968446bfa2acf908fc
record_format Article
spelling doaj-34686865a0a24d968446bfa2acf908fc2020-11-24T22:03:17ZengHindawi LimitedBioMed Research International2314-61332314-61412013-01-01201310.1155/2013/150143150143An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)Jolanta Karpowicz0Krzysztof Gryz1Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Ulica Czerniakowska 16, 00-701 Warszawa, PolandLaboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Ulica Czerniakowska 16, 00-701 Warszawa, PolandLeakage of electromagnetic fields (EMF) from short-wave radiofrequency physiotherapeutic diathermies (SWDs) may cause health and safety hazards affecting unintentionally exposed workers (W) or general public (GP) members (assisting patient exposed during treatment or presenting there for other reasons). Increasing use of electronic active implantable medical devices (AIMDs), by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators) were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users). Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated). Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both—GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment).http://dx.doi.org/10.1155/2013/150143
collection DOAJ
language English
format Article
sources DOAJ
author Jolanta Karpowicz
Krzysztof Gryz
spellingShingle Jolanta Karpowicz
Krzysztof Gryz
An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
BioMed Research International
author_facet Jolanta Karpowicz
Krzysztof Gryz
author_sort Jolanta Karpowicz
title An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
title_short An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
title_full An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
title_fullStr An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
title_full_unstemmed An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD)
title_sort assessment of hazards caused by electromagnetic interaction on humans present near short-wave physiotherapeutic devices of various types including hazards for users of electronic active implantable medical devices (aimd)
publisher Hindawi Limited
series BioMed Research International
issn 2314-6133
2314-6141
publishDate 2013-01-01
description Leakage of electromagnetic fields (EMF) from short-wave radiofrequency physiotherapeutic diathermies (SWDs) may cause health and safety hazards affecting unintentionally exposed workers (W) or general public (GP) members (assisting patient exposed during treatment or presenting there for other reasons). Increasing use of electronic active implantable medical devices (AIMDs), by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators) were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users). Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated). Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both—GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment).
url http://dx.doi.org/10.1155/2013/150143
work_keys_str_mv AT jolantakarpowicz anassessmentofhazardscausedbyelectromagneticinteractiononhumanspresentnearshortwavephysiotherapeuticdevicesofvarioustypesincludinghazardsforusersofelectronicactiveimplantablemedicaldevicesaimd
AT krzysztofgryz anassessmentofhazardscausedbyelectromagneticinteractiononhumanspresentnearshortwavephysiotherapeuticdevicesofvarioustypesincludinghazardsforusersofelectronicactiveimplantablemedicaldevicesaimd
AT jolantakarpowicz assessmentofhazardscausedbyelectromagneticinteractiononhumanspresentnearshortwavephysiotherapeuticdevicesofvarioustypesincludinghazardsforusersofelectronicactiveimplantablemedicaldevicesaimd
AT krzysztofgryz assessmentofhazardscausedbyelectromagneticinteractiononhumanspresentnearshortwavephysiotherapeuticdevicesofvarioustypesincludinghazardsforusersofelectronicactiveimplantablemedicaldevicesaimd
_version_ 1725832293742804992