Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection
mc/ml, and the elapsed time – 20 minutes. The IE is specific to other members of the family Ricketsiaceae, for instance to R. prowazekii , to antigen complexes of R. prowazekii and R. sibirika , as well as to vaccinia virus (L-IVP strain). The IE engineered can be used for rapid indication of Burnet...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Federal Government Health Institution, Russian Research Anti-Plague Institute “Microbe”
2013-12-01
|
Series: | Проблемы особо опасных инфекций |
Subjects: | |
Online Access: | https://journal.microbe.ru/jour/article/view/84 |
id |
doaj-33eae54892f342359d3db7ffc0cfca4d |
---|---|
record_format |
Article |
spelling |
doaj-33eae54892f342359d3db7ffc0cfca4d2021-07-22T07:51:36ZrusFederal Government Health Institution, Russian Research Anti-Plague Institute “Microbe”Проблемы особо опасных инфекций0370-10692658-719X2013-12-0104798110.21055/0370-1069-2013-4-79-8184Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia DetectionL. A. Basharova0S. P. Yarkov1S. I. Tret’Yakov2V. N. Zlobin3State Research Institute for Biological Instrumentation EngineeringState Research Institute for Biological Instrumentation EngineeringState Research Institute for Biological Instrumentation EngineeringState Research Institute for Biological Instrumentation Engineeringmc/ml, and the elapsed time – 20 minutes. The IE is specific to other members of the family Ricketsiaceae, for instance to R. prowazekii , to antigen complexes of R. prowazekii and R. sibirika , as well as to vaccinia virus (L-IVP strain). The IE engineered can be used for rapid indication of Burnet Rickettsia at different stages of laboratory investigation. Span time reduction, lack of necessity to perform any accessory technological operations, visual and (or) automatic registration of the results build up premises to observe immune-chromatographic method for Burnet Rickettsia detection as one of the alternatives for identification of these microorganisms under field conditions when monitoring ambient environment objects.https://journal.microbe.ru/jour/article/view/84иммунохроматографиявыявлениеcoxiella burnetiiimmune-chromatographydetection |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
L. A. Basharova S. P. Yarkov S. I. Tret’Yakov V. N. Zlobin |
spellingShingle |
L. A. Basharova S. P. Yarkov S. I. Tret’Yakov V. N. Zlobin Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection Проблемы особо опасных инфекций иммунохроматография выявление coxiella burnetii immune-chromatography detection |
author_facet |
L. A. Basharova S. P. Yarkov S. I. Tret’Yakov V. N. Zlobin |
author_sort |
L. A. Basharova |
title |
Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection |
title_short |
Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection |
title_full |
Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection |
title_fullStr |
Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection |
title_full_unstemmed |
Construction of Immune-Chromatographic Indicator Elements for Burnet Rickettsia Detection |
title_sort |
construction of immune-chromatographic indicator elements for burnet rickettsia detection |
publisher |
Federal Government Health Institution, Russian Research Anti-Plague Institute “Microbe” |
series |
Проблемы особо опасных инфекций |
issn |
0370-1069 2658-719X |
publishDate |
2013-12-01 |
description |
mc/ml, and the elapsed time – 20 minutes. The IE is specific to other members of the family Ricketsiaceae, for instance to R. prowazekii , to antigen complexes of R. prowazekii and R. sibirika , as well as to vaccinia virus (L-IVP strain). The IE engineered can be used for rapid indication of Burnet Rickettsia at different stages of laboratory investigation. Span time reduction, lack of necessity to perform any accessory technological operations, visual and (or) automatic registration of the results build up premises to observe immune-chromatographic method for Burnet Rickettsia detection as one of the alternatives for identification of these microorganisms under field conditions when monitoring ambient environment objects. |
topic |
иммунохроматография выявление coxiella burnetii immune-chromatography detection |
url |
https://journal.microbe.ru/jour/article/view/84 |
work_keys_str_mv |
AT labasharova constructionofimmunechromatographicindicatorelementsforburnetrickettsiadetection AT spyarkov constructionofimmunechromatographicindicatorelementsforburnetrickettsiadetection AT sitretyakov constructionofimmunechromatographicindicatorelementsforburnetrickettsiadetection AT vnzlobin constructionofimmunechromatographicindicatorelementsforburnetrickettsiadetection |
_version_ |
1721291840792035328 |