Relation between axial length and ocular parameters

AIM: To investigatethe relation between axial length(AL), age and ocular parameters.<p>METHODS: A total of 360 subjects(360 eyes)with emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT), AL, intraocular pressure(IOP)were measured by automatic-refractor, Pachymeter, A...

Full description

Bibliographic Details
Main Authors: Xue-Qiu Yang, Shan-Shan Li, Jing-Jing Zhao, Wen-Juan Zhuang
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2013-09-01
Series:Guoji Yanke Zazhi
Subjects:
age
Online Access:http://www.ies.net.cn/cn_publish/2013/9/201309068.pdf
id doaj-3385df3900b642109eddfbb471f0911b
record_format Article
spelling doaj-3385df3900b642109eddfbb471f0911b2020-11-24T21:06:09ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51232013-09-011391938194210.3980/j.issn.1672-5123.2013.09.68Relation between axial length and ocular parametersXue-Qiu YangShan-Shan LiJing-Jing ZhaoWen-Juan ZhuangAIM: To investigatethe relation between axial length(AL), age and ocular parameters.<p>METHODS: A total of 360 subjects(360 eyes)with emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT), AL, intraocular pressure(IOP)were measured by automatic-refractor, Pachymeter, A-mode ultrasound and non-contact tonometer, respectively. Corneal curvature(CC), anterior chamber depth(ACD)and white-to-white distance(WWD)were measured by Orbscan II. Three dimensional frequency domain coherent optical tomography(3D-OCT)was used to examine the retinal nerve fiber layer thickness(RNFLT). The Pearson correlation coefficient(<i>r</i>)and multiple regression analysis were performed to evaluate the relationship between AL, age and ocular parameters.<p>RESULTS: The average AL was 24.15±1.26mm. With elongation of the AL, spherical equivalent(SE)(<i>r</i>=-0.742,<i>P</i><0.01), CC(<i>r</i>=-0.395, <i>P</i><0.01)and RNFLT(<i>r</i>=-0.374, <i>P</i><0.01)all decreased, while the mean ACD(<i>r</i>=0.411, <i>P</i><0.01)increased. On the contrary, there was not statistical significan with CCT(<i>r</i>=0.099, <i>P</i>=0.060)and WWD(<i>r</i>=0.061, <i>P</i>=0.252). There was also a significant correlation between AL and age(<i>P</i>=0.001), SE(<i>P</i><0.001), ACD(<i>P</i><0.001), CC(<i>P</i><0.001)in Multiple linear regression analysis.<p>CONCLUSION: In longer eyes, there is a tendency toward myopia, a flatter cornea, a deeper ACD and a thinner RNFLT. Age is an influencing factor for the AL as well.http://www.ies.net.cn/cn_publish/2013/9/201309068.pdfaxial lengthageocular parameterrefractive error
collection DOAJ
language English
format Article
sources DOAJ
author Xue-Qiu Yang
Shan-Shan Li
Jing-Jing Zhao
Wen-Juan Zhuang
spellingShingle Xue-Qiu Yang
Shan-Shan Li
Jing-Jing Zhao
Wen-Juan Zhuang
Relation between axial length and ocular parameters
Guoji Yanke Zazhi
axial length
age
ocular parameter
refractive error
author_facet Xue-Qiu Yang
Shan-Shan Li
Jing-Jing Zhao
Wen-Juan Zhuang
author_sort Xue-Qiu Yang
title Relation between axial length and ocular parameters
title_short Relation between axial length and ocular parameters
title_full Relation between axial length and ocular parameters
title_fullStr Relation between axial length and ocular parameters
title_full_unstemmed Relation between axial length and ocular parameters
title_sort relation between axial length and ocular parameters
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
publishDate 2013-09-01
description AIM: To investigatethe relation between axial length(AL), age and ocular parameters.<p>METHODS: A total of 360 subjects(360 eyes)with emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT), AL, intraocular pressure(IOP)were measured by automatic-refractor, Pachymeter, A-mode ultrasound and non-contact tonometer, respectively. Corneal curvature(CC), anterior chamber depth(ACD)and white-to-white distance(WWD)were measured by Orbscan II. Three dimensional frequency domain coherent optical tomography(3D-OCT)was used to examine the retinal nerve fiber layer thickness(RNFLT). The Pearson correlation coefficient(<i>r</i>)and multiple regression analysis were performed to evaluate the relationship between AL, age and ocular parameters.<p>RESULTS: The average AL was 24.15±1.26mm. With elongation of the AL, spherical equivalent(SE)(<i>r</i>=-0.742,<i>P</i><0.01), CC(<i>r</i>=-0.395, <i>P</i><0.01)and RNFLT(<i>r</i>=-0.374, <i>P</i><0.01)all decreased, while the mean ACD(<i>r</i>=0.411, <i>P</i><0.01)increased. On the contrary, there was not statistical significan with CCT(<i>r</i>=0.099, <i>P</i>=0.060)and WWD(<i>r</i>=0.061, <i>P</i>=0.252). There was also a significant correlation between AL and age(<i>P</i>=0.001), SE(<i>P</i><0.001), ACD(<i>P</i><0.001), CC(<i>P</i><0.001)in Multiple linear regression analysis.<p>CONCLUSION: In longer eyes, there is a tendency toward myopia, a flatter cornea, a deeper ACD and a thinner RNFLT. Age is an influencing factor for the AL as well.
topic axial length
age
ocular parameter
refractive error
url http://www.ies.net.cn/cn_publish/2013/9/201309068.pdf
work_keys_str_mv AT xueqiuyang relationbetweenaxiallengthandocularparameters
AT shanshanli relationbetweenaxiallengthandocularparameters
AT jingjingzhao relationbetweenaxiallengthandocularparameters
AT wenjuanzhuang relationbetweenaxiallengthandocularparameters
_version_ 1716766602573119488