Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation

This paper focuses on the performance analysis of a sensorless control for a Doubly Fed Induction Generator (DFIG) in grid-connected operation for turbine-based wind generation systems. With reference to a conventional stator flux based Field Oriented Control (FOC), a full-order adaptive observer is...

Full description

Bibliographic Details
Main Authors: Gianluca Brando, Adolfo Dannier, Ivan Spina
Format: Article
Language:English
Published: MDPI AG 2021-02-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/5/1254
id doaj-334f94a5763d4290a40dbbed33600e9d
record_format Article
spelling doaj-334f94a5763d4290a40dbbed33600e9d2021-02-26T00:04:07ZengMDPI AGEnergies1996-10732021-02-01141254125410.3390/en14051254Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected OperationGianluca Brando0Adolfo Dannier1Ivan Spina2Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, ItalyDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, ItalyDepartment of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, ItalyThis paper focuses on the performance analysis of a sensorless control for a Doubly Fed Induction Generator (DFIG) in grid-connected operation for turbine-based wind generation systems. With reference to a conventional stator flux based Field Oriented Control (FOC), a full-order adaptive observer is implemented and a criterion to calculate the observer gain matrix is provided. The observer provides the estimated stator flux and an estimation of the rotor position is also obtained through the measurements of stator and rotor phase currents. Due to parameter inaccuracy, the rotor position estimation is affected by an error. As a novelty of the discussed approach, the rotor position estimation error is considered as an additional machine parameter, and an error tracking procedure is envisioned in order to track the DFIG rotor position with better accuracy. In particular, an adaptive law based on the Lyapunov theory is implemented for the tracking of the rotor position estimation error, and a current injection strategy is developed in order to ensure the necessary tracking sensitivity around zero rotor voltages. The roughly evaluated rotor position can be corrected by means of the tracked rotor position estimation error, so that the corrected rotor position is sent to the FOC for the necessary rotating coordinate transformation. An extensive experimental analysis is carried out on an 11 kW, 4 poles, 400 V/50 Hz induction machine testifying the quality of the sensorless control.https://www.mdpi.com/1996-1073/14/5/1254doubly-fed induction generatorwind power systemsensorless controlfull order observerfield oriented controlgrid connected system
collection DOAJ
language English
format Article
sources DOAJ
author Gianluca Brando
Adolfo Dannier
Ivan Spina
spellingShingle Gianluca Brando
Adolfo Dannier
Ivan Spina
Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
Energies
doubly-fed induction generator
wind power system
sensorless control
full order observer
field oriented control
grid connected system
author_facet Gianluca Brando
Adolfo Dannier
Ivan Spina
author_sort Gianluca Brando
title Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
title_short Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
title_full Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
title_fullStr Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
title_full_unstemmed Performance Analysis of a Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator in Grid Connected Operation
title_sort performance analysis of a full order sensorless control adaptive observer for doubly-fed induction generator in grid connected operation
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2021-02-01
description This paper focuses on the performance analysis of a sensorless control for a Doubly Fed Induction Generator (DFIG) in grid-connected operation for turbine-based wind generation systems. With reference to a conventional stator flux based Field Oriented Control (FOC), a full-order adaptive observer is implemented and a criterion to calculate the observer gain matrix is provided. The observer provides the estimated stator flux and an estimation of the rotor position is also obtained through the measurements of stator and rotor phase currents. Due to parameter inaccuracy, the rotor position estimation is affected by an error. As a novelty of the discussed approach, the rotor position estimation error is considered as an additional machine parameter, and an error tracking procedure is envisioned in order to track the DFIG rotor position with better accuracy. In particular, an adaptive law based on the Lyapunov theory is implemented for the tracking of the rotor position estimation error, and a current injection strategy is developed in order to ensure the necessary tracking sensitivity around zero rotor voltages. The roughly evaluated rotor position can be corrected by means of the tracked rotor position estimation error, so that the corrected rotor position is sent to the FOC for the necessary rotating coordinate transformation. An extensive experimental analysis is carried out on an 11 kW, 4 poles, 400 V/50 Hz induction machine testifying the quality of the sensorless control.
topic doubly-fed induction generator
wind power system
sensorless control
full order observer
field oriented control
grid connected system
url https://www.mdpi.com/1996-1073/14/5/1254
work_keys_str_mv AT gianlucabrando performanceanalysisofafullordersensorlesscontroladaptiveobserverfordoublyfedinductiongeneratoringridconnectedoperation
AT adolfodannier performanceanalysisofafullordersensorlesscontroladaptiveobserverfordoublyfedinductiongeneratoringridconnectedoperation
AT ivanspina performanceanalysisofafullordersensorlesscontroladaptiveobserverfordoublyfedinductiongeneratoringridconnectedoperation
_version_ 1724250334966054912