Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both per...

Full description

Bibliographic Details
Main Authors: Mehmet Kola, Hikmet Duran, Adem Turk, Suleyman Mollamehmetoglu, Ahmet Kalkisim, Hidayet Erdol
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2014/739652
id doaj-332f7b28e6f64f2bb32d9670d60907fc
record_format Article
spelling doaj-332f7b28e6f64f2bb32d9670d60907fc2020-11-24T22:09:16ZengHindawi LimitedJournal of Ophthalmology2090-004X2090-00582014-01-01201410.1155/2014/739652739652Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by ResidentsMehmet Kola0Hikmet Duran1Adem Turk2Suleyman Mollamehmetoglu3Ahmet Kalkisim4Hidayet Erdol5Department of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyDepartment of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyDepartment of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyDepartment of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyDepartment of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyDepartment of Ophthalmology, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, TurkeyPurpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.http://dx.doi.org/10.1155/2014/739652
collection DOAJ
language English
format Article
sources DOAJ
author Mehmet Kola
Hikmet Duran
Adem Turk
Suleyman Mollamehmetoglu
Ahmet Kalkisim
Hidayet Erdol
spellingShingle Mehmet Kola
Hikmet Duran
Adem Turk
Suleyman Mollamehmetoglu
Ahmet Kalkisim
Hidayet Erdol
Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
Journal of Ophthalmology
author_facet Mehmet Kola
Hikmet Duran
Adem Turk
Suleyman Mollamehmetoglu
Ahmet Kalkisim
Hidayet Erdol
author_sort Mehmet Kola
title Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_short Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_full Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_fullStr Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_full_unstemmed Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_sort evaluation of the repeatability and the reproducibility of al-scan measurements obtained by residents
publisher Hindawi Limited
series Journal of Ophthalmology
issn 2090-004X
2090-0058
publishDate 2014-01-01
description Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.
url http://dx.doi.org/10.1155/2014/739652
work_keys_str_mv AT mehmetkola evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT hikmetduran evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT ademturk evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT suleymanmollamehmetoglu evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT ahmetkalkisim evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT hidayeterdol evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
_version_ 1725812714819813376