MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS

Knowing the operated the knee biomechanical behavior is important during the life of the endoprosthesis,lifestyle changes and medical rehabilitation. One of the main causes of failure of a primary total prosthetic knee joint isthe instability. From the moment of its implantation, the endoprosthesis...

Full description

Bibliographic Details
Main Authors: Marius GRĂMADĂ, Paul BOTEZ, JP Forthomme
Format: Article
Language:English
Published: ALTIUS ACADEMY Foundation - Faculty of Physical Education and Sports 2012-07-01
Series:Sport şi Societate
Subjects:
Online Access:http://www.sportsisocietate.ro/misc/doc/show/64
id doaj-33188406ab02453e89d77ac483d64af2
record_format Article
spelling doaj-33188406ab02453e89d77ac483d64af22021-01-02T02:24:19ZengALTIUS ACADEMY Foundation - Faculty of Physical Education and SportsSport şi Societate1582-21682012-07-011216570MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICSMarius GRĂMADĂPaul BOTEZJP ForthommeKnowing the operated the knee biomechanical behavior is important during the life of the endoprosthesis,lifestyle changes and medical rehabilitation. One of the main causes of failure of a primary total prosthetic knee joint isthe instability. From the moment of its implantation, the endoprosthesis is subjected to external forces, which tend todestabilize it, while the muscles and pericapsulare ligaments oppose it. Theoretically there is a relationship between theexternal disturbing force, respectively ligament tension and the knee frontal plane deviation. The purpose of this paperis to test several mathematical models describing the biomechanical behavior of knee ligaments in relation todeviation. On a group of 39 patients we measured the torque of the joint capsule in relation to the deviation using apressure sensor tensor and a torque screwdriver, and we analyzed these data using a statistical program. We havedemonstrated the existence of this relationship as a function of degree 2 and we made predictions based on itcalculating ligament torque and ligament stiffness at 0 and 5 degrees of deviation. The conclusion of this study showsthat there is a strong relationship between ligament torque and deviation knee, which can be described mathematically.This model can be used to study the knee operated and improve the prosthetic devices.http://www.sportsisocietate.ro/misc/doc/show/64ligament torquedeviationendoprosthesis
collection DOAJ
language English
format Article
sources DOAJ
author Marius GRĂMADĂ
Paul BOTEZ
JP Forthomme
spellingShingle Marius GRĂMADĂ
Paul BOTEZ
JP Forthomme
MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
Sport şi Societate
ligament torque
deviation
endoprosthesis
author_facet Marius GRĂMADĂ
Paul BOTEZ
JP Forthomme
author_sort Marius GRĂMADĂ
title MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
title_short MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
title_full MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
title_fullStr MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
title_full_unstemmed MATHEMATICAL MODEL SUGGESTED FOR THE STUDY OF THE KNEE MECHANICS
title_sort mathematical model suggested for the study of the knee mechanics
publisher ALTIUS ACADEMY Foundation - Faculty of Physical Education and Sports
series Sport şi Societate
issn 1582-2168
publishDate 2012-07-01
description Knowing the operated the knee biomechanical behavior is important during the life of the endoprosthesis,lifestyle changes and medical rehabilitation. One of the main causes of failure of a primary total prosthetic knee joint isthe instability. From the moment of its implantation, the endoprosthesis is subjected to external forces, which tend todestabilize it, while the muscles and pericapsulare ligaments oppose it. Theoretically there is a relationship between theexternal disturbing force, respectively ligament tension and the knee frontal plane deviation. The purpose of this paperis to test several mathematical models describing the biomechanical behavior of knee ligaments in relation todeviation. On a group of 39 patients we measured the torque of the joint capsule in relation to the deviation using apressure sensor tensor and a torque screwdriver, and we analyzed these data using a statistical program. We havedemonstrated the existence of this relationship as a function of degree 2 and we made predictions based on itcalculating ligament torque and ligament stiffness at 0 and 5 degrees of deviation. The conclusion of this study showsthat there is a strong relationship between ligament torque and deviation knee, which can be described mathematically.This model can be used to study the knee operated and improve the prosthetic devices.
topic ligament torque
deviation
endoprosthesis
url http://www.sportsisocietate.ro/misc/doc/show/64
work_keys_str_mv AT mariusgramada mathematicalmodelsuggestedforthestudyofthekneemechanics
AT paulbotez mathematicalmodelsuggestedforthestudyofthekneemechanics
AT jpforthomme mathematicalmodelsuggestedforthestudyofthekneemechanics
_version_ 1724361994378674176