Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion
This paper adopts the method of steel tube wall thickness and strength reduction to simulate corrosion damage. The numerical model of the square concrete-filled steel tube long column (SCFST-LC) under eccentric compression after acid rain corrosion is established in the finite element software, ABAQ...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-05-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/14/10/2568 |
id |
doaj-3300ab53bb4f490c856629db5cb36b8c |
---|---|
record_format |
Article |
spelling |
doaj-3300ab53bb4f490c856629db5cb36b8c2021-06-01T00:06:15ZengMDPI AGMaterials1996-19442021-05-01142568256810.3390/ma14102568Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain CorrosionXuetao Lyu0Liqiang Zhang1Tong Zhang2Ben Li3Huan Li4Yang Yu5Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, ChinaSchool of Civil Engineering, Liaoning Technical University, Fuxin 123000, ChinaSchool of Civil Engineering, Liaoning Technical University, Fuxin 123000, ChinaAdvanced and Sustainable Infrastructure Materials Group, School of Transportation, Civil Engineering and Architecture, Foshan University, Foshan 528000, ChinaSchool of Civil and Environmental Engineering, University of Technology Sydney, Ultimo, NSW 2007, AustraliaCentre for Infrastructure Engineering, Western Sydney University, Penrith, NSW 2751, AustraliaThis paper adopts the method of steel tube wall thickness and strength reduction to simulate corrosion damage. The numerical model of the square concrete-filled steel tube long column (SCFST-LC) under eccentric compression after acid rain corrosion is established in the finite element software, ABAQUS. The reliability and accuracy of the model are verified by comparing it with published relevant experimental results. The failure mode, load-deformation curve, and ultimate compressive load were analysed. Following that, the impacts of section size, yield strength of the steel tube, axial compressive strength of concrete, steel ratio, slenderness ratio, and load eccentricity on its ultimate compressive load are comprehensively investigated. The results demonstrate that the ultimate compressive load of the SCFST-LC decreases significantly with the increase in corrosion rate. The corrosion rate increases from 10 to 40%, and the ultimate bearing capacity decreases by 37.6%. Its ultimate bearing capacity can be enhanced due to the increase in section size, material strength, and steel ratio. In contrast, the ascending slenderness ratio and load eccentricity has harmful effects on the ultimate compressive load of the specimens. Finally, a simplified formula for the axial compressive load of the SCFST-LC under eccentric compression after acid rain corrosion is proposed. The calculation accuracy is high and the deviation of the results is basically within 15%, which is in good agreement with the numerical simulation results.https://www.mdpi.com/1996-1944/14/10/2568acid rain corrosionconcrete-filled square steel tube long columneccentric compressionultimate bearing capacityfinite element analysis |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xuetao Lyu Liqiang Zhang Tong Zhang Ben Li Huan Li Yang Yu |
spellingShingle |
Xuetao Lyu Liqiang Zhang Tong Zhang Ben Li Huan Li Yang Yu Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion Materials acid rain corrosion concrete-filled square steel tube long column eccentric compression ultimate bearing capacity finite element analysis |
author_facet |
Xuetao Lyu Liqiang Zhang Tong Zhang Ben Li Huan Li Yang Yu |
author_sort |
Xuetao Lyu |
title |
Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion |
title_short |
Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion |
title_full |
Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion |
title_fullStr |
Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion |
title_full_unstemmed |
Prediction and Analysis of Ultimate Bearing Capacity of Square CFST Long Column under Eccentric Compression after Acid Rain Corrosion |
title_sort |
prediction and analysis of ultimate bearing capacity of square cfst long column under eccentric compression after acid rain corrosion |
publisher |
MDPI AG |
series |
Materials |
issn |
1996-1944 |
publishDate |
2021-05-01 |
description |
This paper adopts the method of steel tube wall thickness and strength reduction to simulate corrosion damage. The numerical model of the square concrete-filled steel tube long column (SCFST-LC) under eccentric compression after acid rain corrosion is established in the finite element software, ABAQUS. The reliability and accuracy of the model are verified by comparing it with published relevant experimental results. The failure mode, load-deformation curve, and ultimate compressive load were analysed. Following that, the impacts of section size, yield strength of the steel tube, axial compressive strength of concrete, steel ratio, slenderness ratio, and load eccentricity on its ultimate compressive load are comprehensively investigated. The results demonstrate that the ultimate compressive load of the SCFST-LC decreases significantly with the increase in corrosion rate. The corrosion rate increases from 10 to 40%, and the ultimate bearing capacity decreases by 37.6%. Its ultimate bearing capacity can be enhanced due to the increase in section size, material strength, and steel ratio. In contrast, the ascending slenderness ratio and load eccentricity has harmful effects on the ultimate compressive load of the specimens. Finally, a simplified formula for the axial compressive load of the SCFST-LC under eccentric compression after acid rain corrosion is proposed. The calculation accuracy is high and the deviation of the results is basically within 15%, which is in good agreement with the numerical simulation results. |
topic |
acid rain corrosion concrete-filled square steel tube long column eccentric compression ultimate bearing capacity finite element analysis |
url |
https://www.mdpi.com/1996-1944/14/10/2568 |
work_keys_str_mv |
AT xuetaolyu predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion AT liqiangzhang predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion AT tongzhang predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion AT benli predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion AT huanli predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion AT yangyu predictionandanalysisofultimatebearingcapacityofsquarecfstlongcolumnundereccentriccompressionafteracidraincorrosion |
_version_ |
1721415758807826432 |