Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm

Nonlinear frequency coupling is assessed with bispectral measures, such as bicoherence. In this study, BisQ, a new bicoherence-derived index, is proposed for assessing nonlinear processes in cardiac regulation. To find BisQ, 110 ten-minute ECG traces obtained from 55 participants were initially stud...

Full description

Bibliographic Details
Main Authors: José Luis Hernández-Caceres, René Iván González-Fernández, Marlis Ontivero-Ortega, Guido Nolte
Format: Article
Language:English
Published: MDPI AG 2020-07-01
Series:Mathematical and Computational Applications
Subjects:
Online Access:https://www.mdpi.com/2297-8747/25/3/45
id doaj-329c89cd662d40378dcec114d80fce94
record_format Article
spelling doaj-329c89cd662d40378dcec114d80fce942020-11-25T03:31:12ZengMDPI AGMathematical and Computational Applications1300-686X2297-87472020-07-0125454510.3390/mca25030045Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart RhythmJosé Luis Hernández-Caceres0René Iván González-Fernández1Marlis Ontivero-Ortega2Guido Nolte3Cuban Center for Neurosciences, La Habana 11600, CubaCuban Center for Neurosciences, La Habana 11600, CubaCuban Center for Neurosciences, La Habana 11600, CubaDepartment of Neurophysiology and Pathophysiology, University Medical Center, Hamburg-Eppendorf, Martinistraße 52, 20251 Hamburg, GermanyNonlinear frequency coupling is assessed with bispectral measures, such as bicoherence. In this study, BisQ, a new bicoherence-derived index, is proposed for assessing nonlinear processes in cardiac regulation. To find BisQ, 110 ten-minute ECG traces obtained from 55 participants were initially studied. Via bispectral analysis, a bicoherence matrix (BC) was obtained from each trace (0.06 to 1.8 Hz with a resolution of 0.01 Hz). Each frequency pair in BC was tested for correlation with the HRV recurrent quantification analysis (RQA) index L<sub>mean</sub>, obtained from tachograms from the same ECG trace. BisQ is the result of adding BC values corresponding to the three frequency pairs exhibiting the highest correlation with L<sub>mean</sub>. BisQ values were estimated for different groups of subjects: healthy persons, persons with arrhythmia, persons with epilepsy, and preterm neonates. ECG traces from persons with arrhythmia showed no significant differences in BisQ values respect to healthy persons, while persons with epilepsy and neonates showed higher BisQ values (<i>p</i> < 0.05; Mann-Whitney U-test). BisQ reflects nonlinear interactions at the level of sinus-and atrial-ventricular nodes, and most likely cardiorespiratory coupling as well. We expect that BisQ will allow for further exploration of cardiac nonlinear dynamics, complementing available HRV indices.https://www.mdpi.com/2297-8747/25/3/45electrocardiogramheart rate variabilitybispectrumrecurrent quantification analysisarrhythmiaepilepsy
collection DOAJ
language English
format Article
sources DOAJ
author José Luis Hernández-Caceres
René Iván González-Fernández
Marlis Ontivero-Ortega
Guido Nolte
spellingShingle José Luis Hernández-Caceres
René Iván González-Fernández
Marlis Ontivero-Ortega
Guido Nolte
Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
Mathematical and Computational Applications
electrocardiogram
heart rate variability
bispectrum
recurrent quantification analysis
arrhythmia
epilepsy
author_facet José Luis Hernández-Caceres
René Iván González-Fernández
Marlis Ontivero-Ortega
Guido Nolte
author_sort José Luis Hernández-Caceres
title Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
title_short Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
title_full Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
title_fullStr Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
title_full_unstemmed Introducing BisQ, A Bicoherence-Based Nonlinear Index to Explore the Heart Rhythm
title_sort introducing bisq, a bicoherence-based nonlinear index to explore the heart rhythm
publisher MDPI AG
series Mathematical and Computational Applications
issn 1300-686X
2297-8747
publishDate 2020-07-01
description Nonlinear frequency coupling is assessed with bispectral measures, such as bicoherence. In this study, BisQ, a new bicoherence-derived index, is proposed for assessing nonlinear processes in cardiac regulation. To find BisQ, 110 ten-minute ECG traces obtained from 55 participants were initially studied. Via bispectral analysis, a bicoherence matrix (BC) was obtained from each trace (0.06 to 1.8 Hz with a resolution of 0.01 Hz). Each frequency pair in BC was tested for correlation with the HRV recurrent quantification analysis (RQA) index L<sub>mean</sub>, obtained from tachograms from the same ECG trace. BisQ is the result of adding BC values corresponding to the three frequency pairs exhibiting the highest correlation with L<sub>mean</sub>. BisQ values were estimated for different groups of subjects: healthy persons, persons with arrhythmia, persons with epilepsy, and preterm neonates. ECG traces from persons with arrhythmia showed no significant differences in BisQ values respect to healthy persons, while persons with epilepsy and neonates showed higher BisQ values (<i>p</i> < 0.05; Mann-Whitney U-test). BisQ reflects nonlinear interactions at the level of sinus-and atrial-ventricular nodes, and most likely cardiorespiratory coupling as well. We expect that BisQ will allow for further exploration of cardiac nonlinear dynamics, complementing available HRV indices.
topic electrocardiogram
heart rate variability
bispectrum
recurrent quantification analysis
arrhythmia
epilepsy
url https://www.mdpi.com/2297-8747/25/3/45
work_keys_str_mv AT joseluishernandezcaceres introducingbisqabicoherencebasednonlinearindextoexploretheheartrhythm
AT reneivangonzalezfernandez introducingbisqabicoherencebasednonlinearindextoexploretheheartrhythm
AT marlisontiveroortega introducingbisqabicoherencebasednonlinearindextoexploretheheartrhythm
AT guidonolte introducingbisqabicoherencebasednonlinearindextoexploretheheartrhythm
_version_ 1724572895962726400