Defining the cost of water impact for thermoelectric power generation

Thermal power plants use large amounts of water, mainly for cooling purposes. Over a long operational period, power-plant cooling can have a large impact on the water source: elevated temperatures of return flows alter the local physical and chemical properties of the water (i.e., quality impact), w...

Full description

Bibliographic Details
Main Author: Fontina Petrakopoulou
Format: Article
Language:English
Published: Elsevier 2021-11-01
Series:Energy Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352484721002158
id doaj-322864ffacd74452ab7a14ee6e729296
record_format Article
spelling doaj-322864ffacd74452ab7a14ee6e7292962021-04-22T13:39:55ZengElsevierEnergy Reports2352-48472021-11-01721012112Defining the cost of water impact for thermoelectric power generationFontina Petrakopoulou0Thermal and Fluid Engineering Department, Universidad Carlos III de Madrid, Avda. de la Universidad 30, 28911 Leganés (Madrid), SpainThermal power plants use large amounts of water, mainly for cooling purposes. Over a long operational period, power-plant cooling can have a large impact on the water source: elevated temperatures of return flows alter the local physical and chemical properties of the water (i.e., quality impact), while water consumption reduces the available water reserves for future and down-stream uses (i.e., Quantity impact). The vulnerability of the energy sector to water availability is an important problem and measures to confront or mitigate this challenge have not yet been adopted. Here, a novel, straightforward methodology to calculate the cost of water impact caused by coal and natural-gas (combined-cycle) plants with once-through and wet-recirculating cooling systems is developed. The goal is to internalize systemic costs related to water use impacts and thereby incentivize more sustainable energy generation practices. The impact is calculated here as a theoretical feedback on the plant’s operational costs, since altered water properties will eventually lead to malfunction or part-load operation. The main parameter affecting the cost of water impact is found to be the temperature rise of the cooling water in the condenser. In plants with once-through cooling systems, the quantity and quality impacts of water use are of a comparable magnitude. The cost of water impacts in facilities with wet-recirculating cooling systems, on the other hand, is determined only by their quantity impact on water resources. Overall, recirculating systems result in a significantly lower water cost when compared to once-through systems. Furthermore, an approximately three times higher cost of water impact is calculated for coal plants in comparison to natural gas plants, which clearly demonstrates the importance of operational efficiency on the water use of power plants.http://www.sciencedirect.com/science/article/pii/S2352484721002158Energy and water nexusPower plantsCoalNatural gasWater costCooling water system
collection DOAJ
language English
format Article
sources DOAJ
author Fontina Petrakopoulou
spellingShingle Fontina Petrakopoulou
Defining the cost of water impact for thermoelectric power generation
Energy Reports
Energy and water nexus
Power plants
Coal
Natural gas
Water cost
Cooling water system
author_facet Fontina Petrakopoulou
author_sort Fontina Petrakopoulou
title Defining the cost of water impact for thermoelectric power generation
title_short Defining the cost of water impact for thermoelectric power generation
title_full Defining the cost of water impact for thermoelectric power generation
title_fullStr Defining the cost of water impact for thermoelectric power generation
title_full_unstemmed Defining the cost of water impact for thermoelectric power generation
title_sort defining the cost of water impact for thermoelectric power generation
publisher Elsevier
series Energy Reports
issn 2352-4847
publishDate 2021-11-01
description Thermal power plants use large amounts of water, mainly for cooling purposes. Over a long operational period, power-plant cooling can have a large impact on the water source: elevated temperatures of return flows alter the local physical and chemical properties of the water (i.e., quality impact), while water consumption reduces the available water reserves for future and down-stream uses (i.e., Quantity impact). The vulnerability of the energy sector to water availability is an important problem and measures to confront or mitigate this challenge have not yet been adopted. Here, a novel, straightforward methodology to calculate the cost of water impact caused by coal and natural-gas (combined-cycle) plants with once-through and wet-recirculating cooling systems is developed. The goal is to internalize systemic costs related to water use impacts and thereby incentivize more sustainable energy generation practices. The impact is calculated here as a theoretical feedback on the plant’s operational costs, since altered water properties will eventually lead to malfunction or part-load operation. The main parameter affecting the cost of water impact is found to be the temperature rise of the cooling water in the condenser. In plants with once-through cooling systems, the quantity and quality impacts of water use are of a comparable magnitude. The cost of water impacts in facilities with wet-recirculating cooling systems, on the other hand, is determined only by their quantity impact on water resources. Overall, recirculating systems result in a significantly lower water cost when compared to once-through systems. Furthermore, an approximately three times higher cost of water impact is calculated for coal plants in comparison to natural gas plants, which clearly demonstrates the importance of operational efficiency on the water use of power plants.
topic Energy and water nexus
Power plants
Coal
Natural gas
Water cost
Cooling water system
url http://www.sciencedirect.com/science/article/pii/S2352484721002158
work_keys_str_mv AT fontinapetrakopoulou definingthecostofwaterimpactforthermoelectricpowergeneration
_version_ 1721514212764680192