Relative Humidity Sensor Based on Microfiber Loop Resonator

A novel relative humidity (RH) sensor based on a microfiber loop resonator (MLR) is proposed and experimentally demonstrated. As refractive index of the microfiber in the MLR is modified by environmental humidity, resonant wavelength of the MLR changes with RH level. By detecting this wavelength shi...

Full description

Bibliographic Details
Main Authors: Yangzi Zheng, Xinyong Dong, Chunliu Zhao, Yi Li, Liyang Shao, Shangzhong Jin
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:Advances in Materials Science and Engineering
Online Access:http://dx.doi.org/10.1155/2013/815930
id doaj-320890acfa524fabb5bdb3bd0c83f1be
record_format Article
spelling doaj-320890acfa524fabb5bdb3bd0c83f1be2020-11-24T22:45:28ZengHindawi LimitedAdvances in Materials Science and Engineering1687-84341687-84422013-01-01201310.1155/2013/815930815930Relative Humidity Sensor Based on Microfiber Loop ResonatorYangzi Zheng0Xinyong Dong1Chunliu Zhao2Yi Li3Liyang Shao4Shangzhong Jin5Institute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaInstitute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaInstitute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaInstitute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaInstitute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaInstitute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, ChinaA novel relative humidity (RH) sensor based on a microfiber loop resonator (MLR) is proposed and experimentally demonstrated. As refractive index of the microfiber in the MLR is modified by environmental humidity, resonant wavelength of the MLR changes with RH level. By detecting this wavelength shift, RH measurement is realized with a linear response sensitivity of 1.8 pm/% RH. The obvious advantage of this technique over others is that no coating of humidity-sensitive material is required.http://dx.doi.org/10.1155/2013/815930
collection DOAJ
language English
format Article
sources DOAJ
author Yangzi Zheng
Xinyong Dong
Chunliu Zhao
Yi Li
Liyang Shao
Shangzhong Jin
spellingShingle Yangzi Zheng
Xinyong Dong
Chunliu Zhao
Yi Li
Liyang Shao
Shangzhong Jin
Relative Humidity Sensor Based on Microfiber Loop Resonator
Advances in Materials Science and Engineering
author_facet Yangzi Zheng
Xinyong Dong
Chunliu Zhao
Yi Li
Liyang Shao
Shangzhong Jin
author_sort Yangzi Zheng
title Relative Humidity Sensor Based on Microfiber Loop Resonator
title_short Relative Humidity Sensor Based on Microfiber Loop Resonator
title_full Relative Humidity Sensor Based on Microfiber Loop Resonator
title_fullStr Relative Humidity Sensor Based on Microfiber Loop Resonator
title_full_unstemmed Relative Humidity Sensor Based on Microfiber Loop Resonator
title_sort relative humidity sensor based on microfiber loop resonator
publisher Hindawi Limited
series Advances in Materials Science and Engineering
issn 1687-8434
1687-8442
publishDate 2013-01-01
description A novel relative humidity (RH) sensor based on a microfiber loop resonator (MLR) is proposed and experimentally demonstrated. As refractive index of the microfiber in the MLR is modified by environmental humidity, resonant wavelength of the MLR changes with RH level. By detecting this wavelength shift, RH measurement is realized with a linear response sensitivity of 1.8 pm/% RH. The obvious advantage of this technique over others is that no coating of humidity-sensitive material is required.
url http://dx.doi.org/10.1155/2013/815930
work_keys_str_mv AT yangzizheng relativehumiditysensorbasedonmicrofiberloopresonator
AT xinyongdong relativehumiditysensorbasedonmicrofiberloopresonator
AT chunliuzhao relativehumiditysensorbasedonmicrofiberloopresonator
AT yili relativehumiditysensorbasedonmicrofiberloopresonator
AT liyangshao relativehumiditysensorbasedonmicrofiberloopresonator
AT shangzhongjin relativehumiditysensorbasedonmicrofiberloopresonator
_version_ 1725688364288442368