Determination of turbine relative efficiency in SHPP
To assess the fulfillment of contract conditions for the equipment delivery, determining the properties and capabilities of a generating unit or some part of it, the measurements carried out under real operating conditions were necessary. In this paper, the results of the test that was carried out i...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Electrical Engineering Institute Nikola Tesla
2017-01-01
|
Series: | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2017/0350-85281727071D.pdf |
Summary: | To assess the fulfillment of contract conditions for the equipment delivery, determining the properties and capabilities of a generating unit or some part of it, the measurements carried out under real operating conditions were necessary. In this paper, the results of the test that was carried out in a small hydropower plant (SHPP), aimed at determining the relative efficiency of the hydraulic turbine and its comparison with the guaranteed values, are presented. The dependence of the turbine efficiency on the turbine discharge was determined based on the test results, using the index method. The test was performed at one net head. |
---|---|
ISSN: | 0350-8528 2406-1212 |