THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE

Switch electric drives are one of the most important and responsible components of railway automation, and therefore require the development and implementation of advanced diagnostic systems. Achievement of the goal is possible only through the use of modern mathematical and software tools. There is...

Full description

Bibliographic Details
Main Author: Serhii Buriak
Format: Article
Language:English
Published: Scientific Route OÜ 2019-11-01
Series:Technology Transfer: Fundamental Principles and Innovative Technical Solutions
Subjects:
Online Access:http://eu-jr.eu/ttfpits/article/view/1025
id doaj-31e02a81d5f042c2a03c79ce4dd537eb
record_format Article
spelling doaj-31e02a81d5f042c2a03c79ce4dd537eb2020-11-25T02:52:03ZengScientific Route OÜTechnology Transfer: Fundamental Principles and Innovative Technical Solutions2585-68392585-68472019-11-013323410.21303/2585-6847.2019.001025THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVESerhii Buriak0Dnipro National University of Railway Transport named after Academician V. LazaryanSwitch electric drives are one of the most important and responsible components of railway automation, and therefore require the development and implementation of advanced diagnostic systems. Achievement of the goal is possible only through the use of modern mathematical and software tools. There is a problem in the use of electric motors for switch electric drives today. The point is that the nature of the load on the engine is determined by the reducer. Deterioration appears on the reducer during operation. The appearance of gaps between the gears causes the instability of the load on the shaft. Measurements and control of the size of the gaps is not performed. To solve this problem, it is proposed to use linear measurement of the gaps of the gears and further modelling of the reducer. This method will allow to determine the arising load fluctuations by the deviation of the angular velocities of rotation of the drive and driven shafts. The effect of the gaps on the system operation is shown by model in the form of transfer functions of the constituent elements and the system of equations. It will be possible to set limit values for the deterioration of the gears of the reducer by the determination the maximum deviation of shafts angular speeds of rotation in order to take measures in advance for their timely replacement and to keep the engines from excessive load. http://eu-jr.eu/ttfpits/article/view/1025еlectric motorswitch electric driverailway automaticsmechanical transmissionreducersingle-mass system
collection DOAJ
language English
format Article
sources DOAJ
author Serhii Buriak
spellingShingle Serhii Buriak
THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
Technology Transfer: Fundamental Principles and Innovative Technical Solutions
еlectric motor
switch electric drive
railway automatics
mechanical transmission
reducer
single-mass system
author_facet Serhii Buriak
author_sort Serhii Buriak
title THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
title_short THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
title_full THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
title_fullStr THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
title_full_unstemmed THE INFLUENCE OF THE GAPS IN THE MECHANICAL TRANSMISSION OF THE REDUCER OF THE SWITCH ELECTRIC DRIVE
title_sort influence of the gaps in the mechanical transmission of the reducer of the switch electric drive
publisher Scientific Route OÜ
series Technology Transfer: Fundamental Principles and Innovative Technical Solutions
issn 2585-6839
2585-6847
publishDate 2019-11-01
description Switch electric drives are one of the most important and responsible components of railway automation, and therefore require the development and implementation of advanced diagnostic systems. Achievement of the goal is possible only through the use of modern mathematical and software tools. There is a problem in the use of electric motors for switch electric drives today. The point is that the nature of the load on the engine is determined by the reducer. Deterioration appears on the reducer during operation. The appearance of gaps between the gears causes the instability of the load on the shaft. Measurements and control of the size of the gaps is not performed. To solve this problem, it is proposed to use linear measurement of the gaps of the gears and further modelling of the reducer. This method will allow to determine the arising load fluctuations by the deviation of the angular velocities of rotation of the drive and driven shafts. The effect of the gaps on the system operation is shown by model in the form of transfer functions of the constituent elements and the system of equations. It will be possible to set limit values for the deterioration of the gears of the reducer by the determination the maximum deviation of shafts angular speeds of rotation in order to take measures in advance for their timely replacement and to keep the engines from excessive load.
topic еlectric motor
switch electric drive
railway automatics
mechanical transmission
reducer
single-mass system
url http://eu-jr.eu/ttfpits/article/view/1025
work_keys_str_mv AT serhiiburiak theinfluenceofthegapsinthemechanicaltransmissionofthereduceroftheswitchelectricdrive
AT serhiiburiak influenceofthegapsinthemechanicaltransmissionofthereduceroftheswitchelectricdrive
_version_ 1724731619805233152