Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions

Plate fin-tube heat exchangers are widely used in air conditioning and refrigeration systems and other industry fields. Various errors made in the manufacturing process can result in the formation of an air gap between the tube and fin. Several numerical simulations were carried out for a symmetric...

Full description

Bibliographic Details
Main Authors: Marcin Łęcki, Dariusz Andrzejewski, Artur N. Gutkowski, Grzegorz Górecki
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Energies
Subjects:
CFD
Online Access:https://www.mdpi.com/1996-1073/14/13/3779
id doaj-31c7883fc771432686353cc926af9b10
record_format Article
spelling doaj-31c7883fc771432686353cc926af9b102021-07-15T15:32:55ZengMDPI AGEnergies1996-10732021-06-01143779377910.3390/en14133779Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow ConditionsMarcin Łęcki0Dariusz Andrzejewski1Artur N. Gutkowski2Grzegorz Górecki3Faculty of Mechanical Engineering, Institute of Turbomachinery, Lodz University of Technology, 219/223 Wolczanska Street, 90-924 Lodz, PolandFaculty of Mechanical Engineering, Institute of Turbomachinery, Lodz University of Technology, 219/223 Wolczanska Street, 90-924 Lodz, PolandFaculty of Mechanical Engineering, Institute of Turbomachinery, Lodz University of Technology, 219/223 Wolczanska Street, 90-924 Lodz, PolandFaculty of Mechanical Engineering, Institute of Turbomachinery, Lodz University of Technology, 219/223 Wolczanska Street, 90-924 Lodz, PolandPlate fin-tube heat exchangers are widely used in air conditioning and refrigeration systems and other industry fields. Various errors made in the manufacturing process can result in the formation of an air gap between the tube and fin. Several numerical simulations were carried out for a symmetric section of plate fin-tube heat exchanger to study the influence of air gap on heat transfer under periodic flow conditions. Different locations and sizes of an air gap spanning 1/2 circumference of the tube were considered for the range of airflow velocities. Velocity and temperature fields for cases with air gap were compared with ideal thermal contact cases. Blocking of heat flow by the gap leads to the reduction of heat transfer rate. Fin discontinuity in the front of the tube causes the smallest reduction of the heat transfer rate in comparison to the ideal tube-fin contact, especially for thin slits. The rear gap position is the worst in the smallest gap range. Therefore, reversing the flow direction can lead to up to a 15% heat transfer increase, if mainly the rear gaps are present. The introduction of a thin slit in the front of the tube leads to convective heat transfer enhancement, which should be further investigated.https://www.mdpi.com/1996-1073/14/13/3779heat exchangerplate-fin tubetube-fin contactCFD
collection DOAJ
language English
format Article
sources DOAJ
author Marcin Łęcki
Dariusz Andrzejewski
Artur N. Gutkowski
Grzegorz Górecki
spellingShingle Marcin Łęcki
Dariusz Andrzejewski
Artur N. Gutkowski
Grzegorz Górecki
Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
Energies
heat exchanger
plate-fin tube
tube-fin contact
CFD
author_facet Marcin Łęcki
Dariusz Andrzejewski
Artur N. Gutkowski
Grzegorz Górecki
author_sort Marcin Łęcki
title Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
title_short Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
title_full Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
title_fullStr Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
title_full_unstemmed Study of the Influence of the Lack of Contact in Plate and Fin and Tube Heat Exchanger on Heat Transfer Efficiency under Periodic Flow Conditions
title_sort study of the influence of the lack of contact in plate and fin and tube heat exchanger on heat transfer efficiency under periodic flow conditions
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2021-06-01
description Plate fin-tube heat exchangers are widely used in air conditioning and refrigeration systems and other industry fields. Various errors made in the manufacturing process can result in the formation of an air gap between the tube and fin. Several numerical simulations were carried out for a symmetric section of plate fin-tube heat exchanger to study the influence of air gap on heat transfer under periodic flow conditions. Different locations and sizes of an air gap spanning 1/2 circumference of the tube were considered for the range of airflow velocities. Velocity and temperature fields for cases with air gap were compared with ideal thermal contact cases. Blocking of heat flow by the gap leads to the reduction of heat transfer rate. Fin discontinuity in the front of the tube causes the smallest reduction of the heat transfer rate in comparison to the ideal tube-fin contact, especially for thin slits. The rear gap position is the worst in the smallest gap range. Therefore, reversing the flow direction can lead to up to a 15% heat transfer increase, if mainly the rear gaps are present. The introduction of a thin slit in the front of the tube leads to convective heat transfer enhancement, which should be further investigated.
topic heat exchanger
plate-fin tube
tube-fin contact
CFD
url https://www.mdpi.com/1996-1073/14/13/3779
work_keys_str_mv AT marcinłecki studyoftheinfluenceofthelackofcontactinplateandfinandtubeheatexchangeronheattransferefficiencyunderperiodicflowconditions
AT dariuszandrzejewski studyoftheinfluenceofthelackofcontactinplateandfinandtubeheatexchangeronheattransferefficiencyunderperiodicflowconditions
AT arturngutkowski studyoftheinfluenceofthelackofcontactinplateandfinandtubeheatexchangeronheattransferefficiencyunderperiodicflowconditions
AT grzegorzgorecki studyoftheinfluenceofthelackofcontactinplateandfinandtubeheatexchangeronheattransferefficiencyunderperiodicflowconditions
_version_ 1721299765388378112