VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION

Objective: Percutaneous nephrostomy (PN) is a medical skill that requires the repetition of hand and eye coordination exercises. The limited opportunity to achieve learning curve at mastering it, increases the morbidity risk to the patient. We therefore developed an Affordable and Applicable Renal...

Full description

Bibliographic Details
Main Authors: Regi Septian, Kuncoro Adi
Format: Article
Language:English
Published: IKATAN AHLI UROLOGI INDONESIA 2020-01-01
Series:Jurnal Urologi Indonesia
Subjects:
Online Access:http://juri.urologi.or.id/juri/article/view/515
id doaj-3198c7ed0a3946c6bfacb9de7f82c1fb
record_format Article
spelling doaj-3198c7ed0a3946c6bfacb9de7f82c1fb2020-11-25T03:06:00ZengIKATAN AHLI UROLOGI INDONESIAJurnal Urologi Indonesia 0853-442X2355-14022020-01-0127110.32421/juri.v27i1.515515VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATIONRegi Septian0Kuncoro Adi1Department of Urology, Faculty of Medicine/Padjadjaran University, Hasan Sadikin General Hospital, BandungDepartment of Urology, Faculty of Medicine/Padjadjaran University, Hasan Sadikin General Hospital, Bandung Objective: Percutaneous nephrostomy (PN) is a medical skill that requires the repetition of hand and eye coordination exercises. The limited opportunity to achieve learning curve at mastering it, increases the morbidity risk to the patient. We therefore developed an Affordable and Applicable Renal Model (AARM) phantom to simulate percutaneous nephrostomy with ultrasound (USG) guiding. Our goal is to present the development of an affordable cost kidney phantom model and evaluate validity (face, content, and construct) with its reliability. Material & Methods: The AARM phantom made from mixture of gelatin, glycerin and sorbitol, then molded with latex gloves comprising the parenchymal portion and the renal pelvicalyceal system connected to a 10Fr nasogastric tube and a 20 cc syringe. Phantom then assessed by urology residents at Hasan Sadikin Hospital Bandung. Senior resident (n=20) who are adept at performing independent PN then compared with junior resident (n=15), and then we analysis both group skills by measure PN initial puncture time and its failure to establish its validity and reliability. Results: This phantom cost production was 30USD (400.000 IDR) and after tested by urology residents, it had simulated the series of PN action steps which described the face and content validation test, with correlation results (Pearson, p<0.05); Very strong (53.8%), strong (30.8%), and medium (15.4%). The reliability test with cronbach alpha value was 0.934 (reliable if cronbach alpha>0.60). The average initial puncture time measure and PN failure result of junior and senior residents are respectively 37.03 ± 9.5 vs 10.90 ± 0.65 seconds and 4.93 ± 1.33 vs 0.75 ± 0.63 times. When both skills performance was analyzed, the senior resident showed significantly (p<0.01) faster and fewer errors. Conclusion: This AARM phantom had successfully represent the whole sequence actions key step of PN skills and this study has been established its validity (face, content and construct). In addition, this phantom material not only made from affordable cost but also applicable and could be used repeatedly (recycled). We propose the use of this AARM phantom simulator as an initial steps practices to introduce percutaneous nephrostomy skills to residents before they went to the operating room. http://juri.urologi.or.id/juri/article/view/515Percutaneous nephrostomy (PN) with ultrasound guideaffordable and applicable phantom (AARM)validation and realibility
collection DOAJ
language English
format Article
sources DOAJ
author Regi Septian
Kuncoro Adi
spellingShingle Regi Septian
Kuncoro Adi
VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
Jurnal Urologi Indonesia
Percutaneous nephrostomy (PN) with ultrasound guide
affordable and applicable phantom (AARM)
validation and realibility
author_facet Regi Septian
Kuncoro Adi
author_sort Regi Septian
title VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
title_short VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
title_full VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
title_fullStr VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
title_full_unstemmed VALIDATION OF AFFORDABLE AND APPLICABLE KIDNEY PHANTOM MODEL (AARM) FOR ULTRASOUND-GUIDED PERCUTANEOUS NEPHROSTOMY SIMULATION
title_sort validation of affordable and applicable kidney phantom model (aarm) for ultrasound-guided percutaneous nephrostomy simulation
publisher IKATAN AHLI UROLOGI INDONESIA
series Jurnal Urologi Indonesia
issn 0853-442X
2355-1402
publishDate 2020-01-01
description Objective: Percutaneous nephrostomy (PN) is a medical skill that requires the repetition of hand and eye coordination exercises. The limited opportunity to achieve learning curve at mastering it, increases the morbidity risk to the patient. We therefore developed an Affordable and Applicable Renal Model (AARM) phantom to simulate percutaneous nephrostomy with ultrasound (USG) guiding. Our goal is to present the development of an affordable cost kidney phantom model and evaluate validity (face, content, and construct) with its reliability. Material & Methods: The AARM phantom made from mixture of gelatin, glycerin and sorbitol, then molded with latex gloves comprising the parenchymal portion and the renal pelvicalyceal system connected to a 10Fr nasogastric tube and a 20 cc syringe. Phantom then assessed by urology residents at Hasan Sadikin Hospital Bandung. Senior resident (n=20) who are adept at performing independent PN then compared with junior resident (n=15), and then we analysis both group skills by measure PN initial puncture time and its failure to establish its validity and reliability. Results: This phantom cost production was 30USD (400.000 IDR) and after tested by urology residents, it had simulated the series of PN action steps which described the face and content validation test, with correlation results (Pearson, p<0.05); Very strong (53.8%), strong (30.8%), and medium (15.4%). The reliability test with cronbach alpha value was 0.934 (reliable if cronbach alpha>0.60). The average initial puncture time measure and PN failure result of junior and senior residents are respectively 37.03 ± 9.5 vs 10.90 ± 0.65 seconds and 4.93 ± 1.33 vs 0.75 ± 0.63 times. When both skills performance was analyzed, the senior resident showed significantly (p<0.01) faster and fewer errors. Conclusion: This AARM phantom had successfully represent the whole sequence actions key step of PN skills and this study has been established its validity (face, content and construct). In addition, this phantom material not only made from affordable cost but also applicable and could be used repeatedly (recycled). We propose the use of this AARM phantom simulator as an initial steps practices to introduce percutaneous nephrostomy skills to residents before they went to the operating room.
topic Percutaneous nephrostomy (PN) with ultrasound guide
affordable and applicable phantom (AARM)
validation and realibility
url http://juri.urologi.or.id/juri/article/view/515
work_keys_str_mv AT regiseptian validationofaffordableandapplicablekidneyphantommodelaarmforultrasoundguidedpercutaneousnephrostomysimulation
AT kuncoroadi validationofaffordableandapplicablekidneyphantommodelaarmforultrasoundguidedpercutaneousnephrostomysimulation
_version_ 1724676039623311360