Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review

Question: Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Design: Systematic review of studies of the psychometric properties of exercise tests. Participants: People older than 18 years with chronic pain, fibro...

Full description

Bibliographic Details
Main Authors: Julia Ratter, Lorenz Radlinger, Cees Lucas
Format: Article
Language:English
Published: Elsevier 2014-09-01
Series:Journal of Physiotherapy
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1836955314000794
id doaj-3136e11dc20242d48bdf9b54718aea45
record_format Article
spelling doaj-3136e11dc20242d48bdf9b54718aea452020-11-24T21:57:31ZengElsevierJournal of Physiotherapy1836-95532014-09-0160314415010.1016/j.jphys.2014.06.011Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic reviewJulia Ratter0Lorenz Radlinger1Cees Lucas2Hospital Rivierenland Tiel, The NetherlandsApplied Research and Development Physiotherapy, Health Division, Bern University of Applied Sciences, SwitzerlandDepartment of Clinical Epidemiology, Biostatistics and Bioinformatics, Medical Faculty, University of Amsterdam, Academic Medical Centre, Amsterdam, The NetherlandsQuestion: Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Design: Systematic review of studies of the psychometric properties of exercise tests. Participants: People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Intervention: Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Outcome measures: Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Results: Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Conclusion: Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. [Ratter J, Radlinger L, Lucas C (2014) Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review. Journal of Physiotherapy 60: 144–150]http://www.sciencedirect.com/science/article/pii/S1836955314000794Chronic painFatigue syndrome (chronic)FibromyalgiaExercise testPsychometricsReview (publication type)
collection DOAJ
language English
format Article
sources DOAJ
author Julia Ratter
Lorenz Radlinger
Cees Lucas
spellingShingle Julia Ratter
Lorenz Radlinger
Cees Lucas
Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
Journal of Physiotherapy
Chronic pain
Fatigue syndrome (chronic)
Fibromyalgia
Exercise test
Psychometrics
Review (publication type)
author_facet Julia Ratter
Lorenz Radlinger
Cees Lucas
author_sort Julia Ratter
title Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
title_short Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
title_full Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
title_fullStr Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
title_full_unstemmed Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
title_sort several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review
publisher Elsevier
series Journal of Physiotherapy
issn 1836-9553
publishDate 2014-09-01
description Question: Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Design: Systematic review of studies of the psychometric properties of exercise tests. Participants: People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Intervention: Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Outcome measures: Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Results: Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Conclusion: Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. [Ratter J, Radlinger L, Lucas C (2014) Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review. Journal of Physiotherapy 60: 144–150]
topic Chronic pain
Fatigue syndrome (chronic)
Fibromyalgia
Exercise test
Psychometrics
Review (publication type)
url http://www.sciencedirect.com/science/article/pii/S1836955314000794
work_keys_str_mv AT juliaratter severalsubmaximalexercisetestsarereliablevalidandacceptableinpeoplewithchronicpainfibromyalgiaorchronicfatigueasystematicreview
AT lorenzradlinger severalsubmaximalexercisetestsarereliablevalidandacceptableinpeoplewithchronicpainfibromyalgiaorchronicfatigueasystematicreview
AT ceeslucas severalsubmaximalexercisetestsarereliablevalidandacceptableinpeoplewithchronicpainfibromyalgiaorchronicfatigueasystematicreview
_version_ 1725855123040632832