A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product

Background: A sensitive high-performance thin layer chromatographic (HPTLC) method was developed for simultaneous determination of beclomethasone dipropionate and salbutamol sulphate from inhalation product. Methods: Chromatographic separation was achieved on aluminium plates pre-coated with silica...

Full description

Bibliographic Details
Main Authors: Nizam Patel, Vijaykumar Kunvarji Parmar
Format: Article
Language:English
Published: Tabriz University of Medical Sciences 2018-06-01
Series:Pharmaceutical Sciences
Subjects:
Online Access:http://journals.tbzmed.ac.ir/PHARM/Manuscript/PHARM-24-131.pdf
id doaj-3125cb4c2cf64d3583802e1a6b9304ed
record_format Article
spelling doaj-3125cb4c2cf64d3583802e1a6b9304ed2021-02-02T04:31:23ZengTabriz University of Medical SciencesPharmaceutical Sciences1735-403X2383-28862018-06-0124213114010.15171/PS.2018.20PHARM_19798_20171006125414A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation ProductNizam Patel0Vijaykumar Kunvarji Parmar1Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology, CHARUSAT Campus, Changa – 388421, Ta. Petlad, Dist. Anand, Gujarat, India.Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology, CHARUSAT Campus, Changa – 388421, Ta. Petlad, Dist. Anand, Gujarat, India.Background: A sensitive high-performance thin layer chromatographic (HPTLC) method was developed for simultaneous determination of beclomethasone dipropionate and salbutamol sulphate from inhalation product. Methods: Chromatographic separation was achieved on aluminium plates pre-coated with silica gel G60 F254 as the stationary phase and methanol:ethyl acetate:toluene:ammonia (3:1:3:0.15) as the mobile phase. The densitometric evaluation was carried out at 232 nm. The developed method was validated as per the ICH Q2 (R1) guidelines. Robustness of the proposed method was assessed using experimental design approach, and results were analyzed graphically. The results of sample analysis by proposed HPTLC method and reported HPLC method were statistically compared. Results: The Rf value of salbutamol sulphate and beclomethasone dipropionate was found to be 0.38±0.02 and 0.72±0.02, correspondingly. The response in terms of peak area was linear over the concentration range of 100-500 ng/spot and 200-1000 ng/spot for beclomethasone dipropionate and salbutamol sulphate, individually, with the regression coefficient values greater than 0.99 for both the drugs. The limit of detection and limit of quantification for beclomethasone dipropionate were found to be 27 ng/spot and 84 ng/spot, respectively and for salbutamol sulphate were 40 ng/spot and 112 ng/spot, respectively. The proposed method was found to be statistically insignificant when compared to the reported method. Conclusion: The proposed method is robust, sensitive, accurate and precise. The method can be applied for the simultaneous estimation of beclomethasone dipropionate and salbutamol sulphate from inhalation product.http://journals.tbzmed.ac.ir/PHARM/Manuscript/PHARM-24-131.pdfHPTLCSalbutamolBeclomethasoneInhalation product
collection DOAJ
language English
format Article
sources DOAJ
author Nizam Patel
Vijaykumar Kunvarji Parmar
spellingShingle Nizam Patel
Vijaykumar Kunvarji Parmar
A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
Pharmaceutical Sciences
HPTLC
Salbutamol
Beclomethasone
Inhalation product
author_facet Nizam Patel
Vijaykumar Kunvarji Parmar
author_sort Nizam Patel
title A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
title_short A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
title_full A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
title_fullStr A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
title_full_unstemmed A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product
title_sort sensitive high-performance thin layer chromatography method for simultaneous determination of salbutamol sulphate and beclomethasone dipropionate from inhalation product
publisher Tabriz University of Medical Sciences
series Pharmaceutical Sciences
issn 1735-403X
2383-2886
publishDate 2018-06-01
description Background: A sensitive high-performance thin layer chromatographic (HPTLC) method was developed for simultaneous determination of beclomethasone dipropionate and salbutamol sulphate from inhalation product. Methods: Chromatographic separation was achieved on aluminium plates pre-coated with silica gel G60 F254 as the stationary phase and methanol:ethyl acetate:toluene:ammonia (3:1:3:0.15) as the mobile phase. The densitometric evaluation was carried out at 232 nm. The developed method was validated as per the ICH Q2 (R1) guidelines. Robustness of the proposed method was assessed using experimental design approach, and results were analyzed graphically. The results of sample analysis by proposed HPTLC method and reported HPLC method were statistically compared. Results: The Rf value of salbutamol sulphate and beclomethasone dipropionate was found to be 0.38±0.02 and 0.72±0.02, correspondingly. The response in terms of peak area was linear over the concentration range of 100-500 ng/spot and 200-1000 ng/spot for beclomethasone dipropionate and salbutamol sulphate, individually, with the regression coefficient values greater than 0.99 for both the drugs. The limit of detection and limit of quantification for beclomethasone dipropionate were found to be 27 ng/spot and 84 ng/spot, respectively and for salbutamol sulphate were 40 ng/spot and 112 ng/spot, respectively. The proposed method was found to be statistically insignificant when compared to the reported method. Conclusion: The proposed method is robust, sensitive, accurate and precise. The method can be applied for the simultaneous estimation of beclomethasone dipropionate and salbutamol sulphate from inhalation product.
topic HPTLC
Salbutamol
Beclomethasone
Inhalation product
url http://journals.tbzmed.ac.ir/PHARM/Manuscript/PHARM-24-131.pdf
work_keys_str_mv AT nizampatel asensitivehighperformancethinlayerchromatographymethodforsimultaneousdeterminationofsalbutamolsulphateandbeclomethasonedipropionatefrominhalationproduct
AT vijaykumarkunvarjiparmar asensitivehighperformancethinlayerchromatographymethodforsimultaneousdeterminationofsalbutamolsulphateandbeclomethasonedipropionatefrominhalationproduct
AT nizampatel sensitivehighperformancethinlayerchromatographymethodforsimultaneousdeterminationofsalbutamolsulphateandbeclomethasonedipropionatefrominhalationproduct
AT vijaykumarkunvarjiparmar sensitivehighperformancethinlayerchromatographymethodforsimultaneousdeterminationofsalbutamolsulphateandbeclomethasonedipropionatefrominhalationproduct
_version_ 1724305582669692928