Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin

The spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions f...

Full description

Bibliographic Details
Main Authors: Gang-Qin Liu, Xi Feng, Ning Wang, Quan Li, Ren-Bao Liu
Format: Article
Language:English
Published: Nature Publishing Group 2019-03-01
Series:Nature Communications
Online Access:https://doi.org/10.1038/s41467-019-09327-2
id doaj-3118d4d5b7ea416ab876bf4a7d824304
record_format Article
spelling doaj-3118d4d5b7ea416ab876bf4a7d8243042021-05-11T12:38:58ZengNature Publishing GroupNature Communications2041-17232019-03-011011810.1038/s41467-019-09327-2Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvinGang-Qin Liu0Xi Feng1Ning Wang2Quan Li3Ren-Bao Liu4Department of Physics, The Chinese University of Hong KongDepartment of Physics, The Chinese University of Hong KongDepartment of Physics, The Chinese University of Hong KongDepartment of Physics, The Chinese University of Hong KongDepartment of Physics, The Chinese University of Hong KongThe spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions for readout.https://doi.org/10.1038/s41467-019-09327-2
collection DOAJ
language English
format Article
sources DOAJ
author Gang-Qin Liu
Xi Feng
Ning Wang
Quan Li
Ren-Bao Liu
spellingShingle Gang-Qin Liu
Xi Feng
Ning Wang
Quan Li
Ren-Bao Liu
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
Nature Communications
author_facet Gang-Qin Liu
Xi Feng
Ning Wang
Quan Li
Ren-Bao Liu
author_sort Gang-Qin Liu
title Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
title_short Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
title_full Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
title_fullStr Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
title_full_unstemmed Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
title_sort coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
publisher Nature Publishing Group
series Nature Communications
issn 2041-1723
publishDate 2019-03-01
description The spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions for readout.
url https://doi.org/10.1038/s41467-019-09327-2
work_keys_str_mv AT gangqinliu coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin
AT xifeng coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin
AT ningwang coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin
AT quanli coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin
AT renbaoliu coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin
_version_ 1721444451312730112