Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by tw...

Full description

Bibliographic Details
Main Authors: Xiangjun Chen, Aleksandar Stojanovic, Yanjun Hua, Jon Roger Eidet, Di Hu, Jingting Wang, Tor Paaske Utheim
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4193795?pdf=render
id doaj-30e2dad55d6d47d68fa688ee3f9c3401
record_format Article
spelling doaj-30e2dad55d6d47d68fa688ee3f9c34012020-11-25T01:20:48ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-01910e10957710.1371/journal.pone.0109577Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.Xiangjun ChenAleksandar StojanovicYanjun HuaJon Roger EidetDi HuJingting WangTor Paaske UtheimPURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.http://europepmc.org/articles/PMC4193795?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Xiangjun Chen
Aleksandar Stojanovic
Yanjun Hua
Jon Roger Eidet
Di Hu
Jingting Wang
Tor Paaske Utheim
spellingShingle Xiangjun Chen
Aleksandar Stojanovic
Yanjun Hua
Jon Roger Eidet
Di Hu
Jingting Wang
Tor Paaske Utheim
Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
PLoS ONE
author_facet Xiangjun Chen
Aleksandar Stojanovic
Yanjun Hua
Jon Roger Eidet
Di Hu
Jingting Wang
Tor Paaske Utheim
author_sort Xiangjun Chen
title Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
title_short Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
title_full Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
title_fullStr Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
title_full_unstemmed Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
title_sort reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-prk eyes.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2014-01-01
description PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.
url http://europepmc.org/articles/PMC4193795?pdf=render
work_keys_str_mv AT xiangjunchen reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT aleksandarstojanovic reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT yanjunhua reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT jonrogereidet reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT dihu reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT jingtingwang reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
AT torpaaskeutheim reliabilityofcornealdynamicscheimpfluganalysermeasurementsinvirginandpostprkeyes
_version_ 1725131963661025280