Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum

To meet the research needs of the freezing temperature field under seepage, we investigate and design a seepage-freezing model test box, which can meet the requirements of strength, deformation, dispersed flow, simulated laminar flow, and water sealing performance. Using theoretical analysis and cal...

Full description

Bibliographic Details
Main Authors: Renliang Shan, Weijun Liu, Zhe Liu, Zhien Wang
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Advances in Materials Science and Engineering
Online Access:http://dx.doi.org/10.1155/2021/5587148
id doaj-30d8b62cba0b4241af555294b7483d9c
record_format Article
spelling doaj-30d8b62cba0b4241af555294b7483d9c2021-06-28T01:51:36ZengHindawi LimitedAdvances in Materials Science and Engineering1687-84422021-01-01202110.1155/2021/5587148Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage StratumRenliang Shan0Weijun Liu1Zhe Liu2Zhien Wang3College of Mechanics and Construction EngineeringCollege of Mechanics and Construction EngineeringCollege of Mechanics and Construction EngineeringCollege of Mechanics and Construction EngineeringTo meet the research needs of the freezing temperature field under seepage, we investigate and design a seepage-freezing model test box, which can meet the requirements of strength, deformation, dispersed flow, simulated laminar flow, and water sealing performance. Using theoretical analysis and calculation, the pressure design index of the model box was obtained. Based on safety considerations, the model test box was designed with a pressure vessel bearing of 0.05 MPa. The structure of “sink + porous plate” was used inside the box. By flow field analysis, the porous plate can effectively reduce the influence of flow convergence to the orifice on the flow field and achieve the purpose of dispersed-water flow and laminar flow simulation. The composite structure form of “panel + frame beam” was adopted to perform the load-bearing test. Under the pressure of 0.05 MPa, the maximum deformation in the x, y, and z directions was <2.4 mm, and the maximum stress was approximately 248 MPa. The model box could meet the requirements of strength and deformation. Water sealing between the upper cover plate and lower box body was achieved by arranging bolts, iron sheets, and silica gel strips. After testing the processed box, we found that the designed box can fully meet the test requirements. These research results may be used as a reference for the development and design of other seepage-freezing model test boxes.http://dx.doi.org/10.1155/2021/5587148
collection DOAJ
language English
format Article
sources DOAJ
author Renliang Shan
Weijun Liu
Zhe Liu
Zhien Wang
spellingShingle Renliang Shan
Weijun Liu
Zhe Liu
Zhien Wang
Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
Advances in Materials Science and Engineering
author_facet Renliang Shan
Weijun Liu
Zhe Liu
Zhien Wang
author_sort Renliang Shan
title Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
title_short Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
title_full Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
title_fullStr Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
title_full_unstemmed Structure Design and Flow Field Analysis of a Model Test Box Used to Study Freezing Temperature Field of Seepage Stratum
title_sort structure design and flow field analysis of a model test box used to study freezing temperature field of seepage stratum
publisher Hindawi Limited
series Advances in Materials Science and Engineering
issn 1687-8442
publishDate 2021-01-01
description To meet the research needs of the freezing temperature field under seepage, we investigate and design a seepage-freezing model test box, which can meet the requirements of strength, deformation, dispersed flow, simulated laminar flow, and water sealing performance. Using theoretical analysis and calculation, the pressure design index of the model box was obtained. Based on safety considerations, the model test box was designed with a pressure vessel bearing of 0.05 MPa. The structure of “sink + porous plate” was used inside the box. By flow field analysis, the porous plate can effectively reduce the influence of flow convergence to the orifice on the flow field and achieve the purpose of dispersed-water flow and laminar flow simulation. The composite structure form of “panel + frame beam” was adopted to perform the load-bearing test. Under the pressure of 0.05 MPa, the maximum deformation in the x, y, and z directions was <2.4 mm, and the maximum stress was approximately 248 MPa. The model box could meet the requirements of strength and deformation. Water sealing between the upper cover plate and lower box body was achieved by arranging bolts, iron sheets, and silica gel strips. After testing the processed box, we found that the designed box can fully meet the test requirements. These research results may be used as a reference for the development and design of other seepage-freezing model test boxes.
url http://dx.doi.org/10.1155/2021/5587148
work_keys_str_mv AT renliangshan structuredesignandflowfieldanalysisofamodeltestboxusedtostudyfreezingtemperaturefieldofseepagestratum
AT weijunliu structuredesignandflowfieldanalysisofamodeltestboxusedtostudyfreezingtemperaturefieldofseepagestratum
AT zheliu structuredesignandflowfieldanalysisofamodeltestboxusedtostudyfreezingtemperaturefieldofseepagestratum
AT zhienwang structuredesignandflowfieldanalysisofamodeltestboxusedtostudyfreezingtemperaturefieldofseepagestratum
_version_ 1721357135349022720