On Using Ray-Launching Method for Modeling Rotational Spectrometer
In this paper the ray-launching method is developed and used for the modeling of a rotational spectrometer. Since the electrical size of the spectrometer is several thousands times longer compared to the wavelength, the presented approach is much suitable for the analysis of such huge devices than t...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Spolecnost pro radioelektronicke inzenyrstvi
2008-06-01
|
Series: | Radioengineering |
Subjects: | |
Online Access: | http://www.radioeng.cz/fulltexts/2008/08_02_098_107.pdf |
id |
doaj-3053d91d0f944231973b4bf0dce9ebc2 |
---|---|
record_format |
Article |
spelling |
doaj-3053d91d0f944231973b4bf0dce9ebc22020-11-24T21:16:21ZengSpolecnost pro radioelektronicke inzenyrstviRadioengineering1210-25122008-06-0117298107On Using Ray-Launching Method for Modeling Rotational SpectrometerZ. RaidaZ. LukesJ. LacikIn this paper the ray-launching method is developed and used for the modeling of a rotational spectrometer. Since the electrical size of the spectrometer is several thousands times longer compared to the wavelength, the presented approach is much suitable for the analysis of such huge devices than the classical numerical exact methods such as the fast integral methods. The accuracy of the developed approach is verified on an analysis of a spectrometer component - a lens. Firstly, the lens is analyzed in CST Microwave Studio, and secondly, by the developed ray-launching method. Comparisons show that the accuracy of the developed approach is good.www.radioeng.cz/fulltexts/2008/08_02_098_107.pdfRay tracingray launchingrotational spectrometerrotational spectroscopy |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Z. Raida Z. Lukes J. Lacik |
spellingShingle |
Z. Raida Z. Lukes J. Lacik On Using Ray-Launching Method for Modeling Rotational Spectrometer Radioengineering Ray tracing ray launching rotational spectrometer rotational spectroscopy |
author_facet |
Z. Raida Z. Lukes J. Lacik |
author_sort |
Z. Raida |
title |
On Using Ray-Launching Method for Modeling Rotational Spectrometer |
title_short |
On Using Ray-Launching Method for Modeling Rotational Spectrometer |
title_full |
On Using Ray-Launching Method for Modeling Rotational Spectrometer |
title_fullStr |
On Using Ray-Launching Method for Modeling Rotational Spectrometer |
title_full_unstemmed |
On Using Ray-Launching Method for Modeling Rotational Spectrometer |
title_sort |
on using ray-launching method for modeling rotational spectrometer |
publisher |
Spolecnost pro radioelektronicke inzenyrstvi |
series |
Radioengineering |
issn |
1210-2512 |
publishDate |
2008-06-01 |
description |
In this paper the ray-launching method is developed and used for the modeling of a rotational spectrometer. Since the electrical size of the spectrometer is several thousands times longer compared to the wavelength, the presented approach is much suitable for the analysis of such huge devices than the classical numerical exact methods such as the fast integral methods. The accuracy of the developed approach is verified on an analysis of a spectrometer component - a lens. Firstly, the lens is analyzed in CST Microwave Studio, and secondly, by the developed ray-launching method. Comparisons show that the accuracy of the developed approach is good. |
topic |
Ray tracing ray launching rotational spectrometer rotational spectroscopy |
url |
http://www.radioeng.cz/fulltexts/2008/08_02_098_107.pdf |
work_keys_str_mv |
AT zraida onusingraylaunchingmethodformodelingrotationalspectrometer AT zlukes onusingraylaunchingmethodformodelingrotationalspectrometer AT jlacik onusingraylaunchingmethodformodelingrotationalspectrometer |
_version_ |
1726015854658715648 |