Difficulties in differentiating the nature of ascites based on ultrasound imaging

Transabdominal ultrasound not always allows to determine the nature of ascites based solely on its characteristics. Aim: The aim of the study was to present difficulties in determining the nature of ascites using transabdominal ultrasonography solely based on extra-organ lesions as well as, after...

Full description

Bibliographic Details
Main Authors: Andrzej Smereczyński, Katarzyna Kołaczyk, Elżbieta Bernatowicz
Format: Article
Language:English
Published: Medical Communications Sp. z o.o. 2017-06-01
Series:Journal of Ultrasonography
Subjects:
Online Access:http://jultrason.pl/index.php/issues/volume-17-no-69/difficulties-in-differentiating-the-nature-of-ascites-based-on-ultrasound-imaging?aid=512
id doaj-30332334f92445ef9ddb4bb47d6b019e
record_format Article
spelling doaj-30332334f92445ef9ddb4bb47d6b019e2020-11-25T01:57:41ZengMedical Communications Sp. z o.o.Journal of Ultrasonography2084-84042451-070X2017-06-0117699610010.15557/JoU.2017.0013Difficulties in differentiating the nature of ascites based on ultrasound imagingAndrzej Smereczyński0Katarzyna Kołaczyk1Elżbieta Bernatowicz2Self-Education Ultrasound Study Group, Department Genetics and Pathomorphology of the Pomeranian Medical University in Szczecin, PolandSelf-Education Ultrasound Study Group, Department Genetics and Pathomorphology of the Pomeranian Medical University in Szczecin, PolandSelf-Education Ultrasound Study Group, Department Genetics and Pathomorphology of the Pomeranian Medical University in Szczecin, PolandTransabdominal ultrasound not always allows to determine the nature of ascites based solely on its characteristics. Aim: The aim of the study was to present difficulties in determining the nature of ascites using transabdominal ultrasonography solely based on extra-organ lesions as well as, after the inclusion of the overall abdominal assessment and the clinical picture. Materials and methods: A total of 18 patients with non-neoplastic ascites and 62 patients with neoplastic ascites whose final diagnosis was based on cytological and histopathological findings were evaluated between 2005 and 2015. Abdominal ultrasound was performed to detect the presence of fluid in all accessible spaces, and, additionally, to determine the presence of potential peritoneal tumor implants as well as to evaluate the parietal peritoneum and the greater omentum. Different digital ultrasound machines equipped with 3–6 MHz and linear 7–12 MHz transducers were used in the study. Double-sided Fisher’s exact test with statistical significance at p < 0.05 was used for the analysis of the obtained results. Results: Statistically significant differences between benign and neoplastic ascites were found for: anechoic peritoneal fluid (<0.0001); fluid and thickened omentum with smooth surface (<0.0001); fluid and thickened omentum with smooth surface and varices (0.01); fluid and thickened omentum with hypoechoic foci (0.049); fluid and thickened omentum with tumor implants (0.009). The inclusion of the overall assessment of abdominal organs and the clinical data allowed for an improvement in ultrasonographic diagnostic accuracy in benign and neoplastic ascites from 83.3% and 67.7% to 94.4% and 93.5%, respectively. Conclusions: When used alone, an assessment of acoustic fluid characteristics and extra-organ peritoneal lesions limits the possibility to differentiate between benign and malignant ascites. These results improve after the inclusion of sonographic assessment of all abdominal organs in combination with clinical data.http://jultrason.pl/index.php/issues/volume-17-no-69/difficulties-in-differentiating-the-nature-of-ascites-based-on-ultrasound-imaging?aid=512ascitesgreater omentumtumor implants
collection DOAJ
language English
format Article
sources DOAJ
author Andrzej Smereczyński
Katarzyna Kołaczyk
Elżbieta Bernatowicz
spellingShingle Andrzej Smereczyński
Katarzyna Kołaczyk
Elżbieta Bernatowicz
Difficulties in differentiating the nature of ascites based on ultrasound imaging
Journal of Ultrasonography
ascites
greater omentum
tumor implants
author_facet Andrzej Smereczyński
Katarzyna Kołaczyk
Elżbieta Bernatowicz
author_sort Andrzej Smereczyński
title Difficulties in differentiating the nature of ascites based on ultrasound imaging
title_short Difficulties in differentiating the nature of ascites based on ultrasound imaging
title_full Difficulties in differentiating the nature of ascites based on ultrasound imaging
title_fullStr Difficulties in differentiating the nature of ascites based on ultrasound imaging
title_full_unstemmed Difficulties in differentiating the nature of ascites based on ultrasound imaging
title_sort difficulties in differentiating the nature of ascites based on ultrasound imaging
publisher Medical Communications Sp. z o.o.
series Journal of Ultrasonography
issn 2084-8404
2451-070X
publishDate 2017-06-01
description Transabdominal ultrasound not always allows to determine the nature of ascites based solely on its characteristics. Aim: The aim of the study was to present difficulties in determining the nature of ascites using transabdominal ultrasonography solely based on extra-organ lesions as well as, after the inclusion of the overall abdominal assessment and the clinical picture. Materials and methods: A total of 18 patients with non-neoplastic ascites and 62 patients with neoplastic ascites whose final diagnosis was based on cytological and histopathological findings were evaluated between 2005 and 2015. Abdominal ultrasound was performed to detect the presence of fluid in all accessible spaces, and, additionally, to determine the presence of potential peritoneal tumor implants as well as to evaluate the parietal peritoneum and the greater omentum. Different digital ultrasound machines equipped with 3–6 MHz and linear 7–12 MHz transducers were used in the study. Double-sided Fisher’s exact test with statistical significance at p < 0.05 was used for the analysis of the obtained results. Results: Statistically significant differences between benign and neoplastic ascites were found for: anechoic peritoneal fluid (<0.0001); fluid and thickened omentum with smooth surface (<0.0001); fluid and thickened omentum with smooth surface and varices (0.01); fluid and thickened omentum with hypoechoic foci (0.049); fluid and thickened omentum with tumor implants (0.009). The inclusion of the overall assessment of abdominal organs and the clinical data allowed for an improvement in ultrasonographic diagnostic accuracy in benign and neoplastic ascites from 83.3% and 67.7% to 94.4% and 93.5%, respectively. Conclusions: When used alone, an assessment of acoustic fluid characteristics and extra-organ peritoneal lesions limits the possibility to differentiate between benign and malignant ascites. These results improve after the inclusion of sonographic assessment of all abdominal organs in combination with clinical data.
topic ascites
greater omentum
tumor implants
url http://jultrason.pl/index.php/issues/volume-17-no-69/difficulties-in-differentiating-the-nature-of-ascites-based-on-ultrasound-imaging?aid=512
work_keys_str_mv AT andrzejsmereczynski difficultiesindifferentiatingthenatureofascitesbasedonultrasoundimaging
AT katarzynakołaczyk difficultiesindifferentiatingthenatureofascitesbasedonultrasoundimaging
AT elzbietabernatowicz difficultiesindifferentiatingthenatureofascitesbasedonultrasoundimaging
_version_ 1724973210658668544