Results of application of external fixation with different types of fixators

Introduction. Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. Objective. The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabil...

Full description

Bibliographic Details
Main Authors: Grubor Predrag, Grubor Milan
Format: Article
Language:English
Published: Serbian Medical Society 2012-01-01
Series:Srpski Arhiv za Celokupno Lekarstvo
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/0370-8179/2012/0370-81791206332G.pdf
id doaj-301268c754f447a8bb50931cc4ee8313
record_format Article
spelling doaj-301268c754f447a8bb50931cc4ee83132021-01-02T00:29:11ZengSerbian Medical SocietySrpski Arhiv za Celokupno Lekarstvo0370-81792012-01-011405-633233810.2298/SARH1206332GResults of application of external fixation with different types of fixatorsGrubor PredragGrubor MilanIntroduction. Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. Objective. The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. Methods. To determine the investigation methodology of biomechanical characteristics of the external fixator we used mathematical and computer simulator (software), juvidur physical model and clinical examination. Results. Values of advancing fragments in millimetres obtained by the study of mathematical and computer simulator (software): Charnley - 0.080 mm, Mitković M 20 - 0.785 mm, Ilizarov - 2.245 mm and Ortofix - 1.400 mm. In testing the juvidur model the following values were obtained: the external fixator Mitković M20 - 1.380 mm, Ortofix - 1.470 mm, Ilizarov - 2.410 mm, and Charnley - 2.510 mm. Clinical research of biomechanical characteristics of the effect of vertical force yielded the following results: Mitković M20 - 0.89 mm, Ortofix - 0.14 mm, Charnley - 0.80 mm and Ilizarov - 1.23 mm. Conclusion. When determining the total number of the stability test splints under the effect of vertical force (compression) and force effect in antero-posterior, later-lateral plane of cross, spiral and comminuted long bone fractures, the best unified biomechanical stability was shown by the following external fixators: firstly, Mitković M20 (0.93mm), secondly, Charnley fixator (1.14 mm), thirdly, Ortofix (1.22 mm), and fourthly, Ilizarov (1.60 mm).http://www.doiserbia.nb.rs/img/doi/0370-8179/2012/0370-81791206332G.pdfexternal fixatorbiomechanicsrange of stability
collection DOAJ
language English
format Article
sources DOAJ
author Grubor Predrag
Grubor Milan
spellingShingle Grubor Predrag
Grubor Milan
Results of application of external fixation with different types of fixators
Srpski Arhiv za Celokupno Lekarstvo
external fixator
biomechanics
range of stability
author_facet Grubor Predrag
Grubor Milan
author_sort Grubor Predrag
title Results of application of external fixation with different types of fixators
title_short Results of application of external fixation with different types of fixators
title_full Results of application of external fixation with different types of fixators
title_fullStr Results of application of external fixation with different types of fixators
title_full_unstemmed Results of application of external fixation with different types of fixators
title_sort results of application of external fixation with different types of fixators
publisher Serbian Medical Society
series Srpski Arhiv za Celokupno Lekarstvo
issn 0370-8179
publishDate 2012-01-01
description Introduction. Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. Objective. The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. Methods. To determine the investigation methodology of biomechanical characteristics of the external fixator we used mathematical and computer simulator (software), juvidur physical model and clinical examination. Results. Values of advancing fragments in millimetres obtained by the study of mathematical and computer simulator (software): Charnley - 0.080 mm, Mitković M 20 - 0.785 mm, Ilizarov - 2.245 mm and Ortofix - 1.400 mm. In testing the juvidur model the following values were obtained: the external fixator Mitković M20 - 1.380 mm, Ortofix - 1.470 mm, Ilizarov - 2.410 mm, and Charnley - 2.510 mm. Clinical research of biomechanical characteristics of the effect of vertical force yielded the following results: Mitković M20 - 0.89 mm, Ortofix - 0.14 mm, Charnley - 0.80 mm and Ilizarov - 1.23 mm. Conclusion. When determining the total number of the stability test splints under the effect of vertical force (compression) and force effect in antero-posterior, later-lateral plane of cross, spiral and comminuted long bone fractures, the best unified biomechanical stability was shown by the following external fixators: firstly, Mitković M20 (0.93mm), secondly, Charnley fixator (1.14 mm), thirdly, Ortofix (1.22 mm), and fourthly, Ilizarov (1.60 mm).
topic external fixator
biomechanics
range of stability
url http://www.doiserbia.nb.rs/img/doi/0370-8179/2012/0370-81791206332G.pdf
work_keys_str_mv AT gruborpredrag resultsofapplicationofexternalfixationwithdifferenttypesoffixators
AT grubormilan resultsofapplicationofexternalfixationwithdifferenttypesoffixators
_version_ 1724363755479891968