Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.

We aimed to compare the assay performance characteristics of HER2 status in mucinous epithelial ovarian cancer (EOC) by ToGA (Trastuzumab for Gastric Cancer) biopsy versus ToGA surgical specimen methods. Forty-nine tissue microarray (TMA) samples of mucinous EOC from Asian women were analyzed by imm...

Full description

Bibliographic Details
Main Authors: Wan-Ru Chao, Ming-Yung Lee, Alexandra Ruan, Huang Pin Sheng, Jeng-Dong Hsu, Chih-Ping Han, Chiew-Loon Koo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4643932?pdf=render
id doaj-2fb182d6562d474fa49e9b1b729374c6
record_format Article
spelling doaj-2fb182d6562d474fa49e9b1b729374c62020-11-25T02:52:37ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-011011e014213510.1371/journal.pone.0142135Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.Wan-Ru ChaoMing-Yung LeeAlexandra RuanHuang Pin ShengJeng-Dong HsuChih-Ping HanChiew-Loon KooWe aimed to compare the assay performance characteristics of HER2 status in mucinous epithelial ovarian cancer (EOC) by ToGA (Trastuzumab for Gastric Cancer) biopsy versus ToGA surgical specimen methods. Forty-nine tissue microarray (TMA) samples of mucinous EOC from Asian women were analyzed by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) tests using ToGA trial HER2 scoring methods. The overall concordance between IHC and FISH by the ToGA surgical specimen method is 97.56% and by the ToGA biopsy specimen method is 97.14%. The agreements of HER2 IHC results under both biopsy and surgical specimen methods were nearly perfect (weighted kappa = 0.845). Additionally, the percentage of Her2 FISH amplification showed increasing trend with increasing HER2 IHC ordinals (negative, equivocal, positive) by both TOGA biopsy (P<0.001) and surgical specimen method (P<0.001). After excluding equivocal cases, the sensitivity (100%), PPV (88.89%) and NPV (100%) of HER2 IHC were unchanged under either surgical specimen method or biopsy method. However, the specificity (96.97%) and accuracy (97.56%) of HER2 IHC was slightly higher under the surgical specimen method than those (specificity 96.30%, accuracy 97.14%) under the biopsy method. Of the total 49 cases, the number (n = 14) of HER2 IHC equivocal results under the ToGA biopsy method was 1.75-fold higher than those (n = 8) under the ToGA surgical specimen method (28.57% vs. 16.32%). Therefore, compared to ToGA surgery specimen method, the ToGA biopsy method caused more equivocal IHC cases to be referred to FISH testing and did not increase the detection rates of Her2 FISH amplification.http://europepmc.org/articles/PMC4643932?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Wan-Ru Chao
Ming-Yung Lee
Alexandra Ruan
Huang Pin Sheng
Jeng-Dong Hsu
Chih-Ping Han
Chiew-Loon Koo
spellingShingle Wan-Ru Chao
Ming-Yung Lee
Alexandra Ruan
Huang Pin Sheng
Jeng-Dong Hsu
Chih-Ping Han
Chiew-Loon Koo
Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
PLoS ONE
author_facet Wan-Ru Chao
Ming-Yung Lee
Alexandra Ruan
Huang Pin Sheng
Jeng-Dong Hsu
Chih-Ping Han
Chiew-Loon Koo
author_sort Wan-Ru Chao
title Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
title_short Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
title_full Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
title_fullStr Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
title_full_unstemmed Assessment of HER2 Status Using Immunohistochemistry (IHC) and Fluorescence In Situ Hybridization (FISH) Techniques in Mucinous Epithelial Ovarian Cancer: A Comprehensive Comparison between ToGA Biopsy Method and ToGA Surgical Specimen Method.
title_sort assessment of her2 status using immunohistochemistry (ihc) and fluorescence in situ hybridization (fish) techniques in mucinous epithelial ovarian cancer: a comprehensive comparison between toga biopsy method and toga surgical specimen method.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2015-01-01
description We aimed to compare the assay performance characteristics of HER2 status in mucinous epithelial ovarian cancer (EOC) by ToGA (Trastuzumab for Gastric Cancer) biopsy versus ToGA surgical specimen methods. Forty-nine tissue microarray (TMA) samples of mucinous EOC from Asian women were analyzed by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) tests using ToGA trial HER2 scoring methods. The overall concordance between IHC and FISH by the ToGA surgical specimen method is 97.56% and by the ToGA biopsy specimen method is 97.14%. The agreements of HER2 IHC results under both biopsy and surgical specimen methods were nearly perfect (weighted kappa = 0.845). Additionally, the percentage of Her2 FISH amplification showed increasing trend with increasing HER2 IHC ordinals (negative, equivocal, positive) by both TOGA biopsy (P<0.001) and surgical specimen method (P<0.001). After excluding equivocal cases, the sensitivity (100%), PPV (88.89%) and NPV (100%) of HER2 IHC were unchanged under either surgical specimen method or biopsy method. However, the specificity (96.97%) and accuracy (97.56%) of HER2 IHC was slightly higher under the surgical specimen method than those (specificity 96.30%, accuracy 97.14%) under the biopsy method. Of the total 49 cases, the number (n = 14) of HER2 IHC equivocal results under the ToGA biopsy method was 1.75-fold higher than those (n = 8) under the ToGA surgical specimen method (28.57% vs. 16.32%). Therefore, compared to ToGA surgery specimen method, the ToGA biopsy method caused more equivocal IHC cases to be referred to FISH testing and did not increase the detection rates of Her2 FISH amplification.
url http://europepmc.org/articles/PMC4643932?pdf=render
work_keys_str_mv AT wanruchao assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT mingyunglee assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT alexandraruan assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT huangpinsheng assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT jengdonghsu assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT chihpinghan assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
AT chiewloonkoo assessmentofher2statususingimmunohistochemistryihcandfluorescenceinsituhybridizationfishtechniquesinmucinousepithelialovariancanceracomprehensivecomparisonbetweentogabiopsymethodandtogasurgicalspecimenmethod
_version_ 1724728751811461120