Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome

Background: Down syndrome (DS) is a genetic disorder that occurs because of an abnormal division between cells that results in an extra copy of chromosome 21. Some studies show that physical exercise in people with DS increases some cognitive capacities, such as memory, and improves the quality of l...

Full description

Bibliographic Details
Main Authors: Ruth Cabeza-Ruiz, Francisco Javier Alcántara-Cordero, Isaac Ruiz-Gavilán, Antonio Manuel Sánchez-López
Format: Article
Language:English
Published: MDPI AG 2019-07-01
Series:International Journal of Environmental Research and Public Health
Subjects:
Online Access:https://www.mdpi.com/1660-4601/16/15/2685
id doaj-2efdf7dacaea46939cc71bb3090501e3
record_format Article
spelling doaj-2efdf7dacaea46939cc71bb3090501e32020-11-25T01:57:18ZengMDPI AGInternational Journal of Environmental Research and Public Health1660-46012019-07-011615268510.3390/ijerph16152685ijerph16152685Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down SyndromeRuth Cabeza-Ruiz0Francisco Javier Alcántara-Cordero1Isaac Ruiz-Gavilán2Antonio Manuel Sánchez-López3Department of Human Motricity and Sports Performance, University of Seville, 41013 Seville, SpainResearch Support Staff, Faculty of Education, University of Seville, 41013 Seville, SpainResearch Fellow, Department of Human Motricity and Sports Performance, University of Seville, 41013 Seville, SpainDepartment of Human Motricity and Sports Performance, University of Seville, 41013 Seville, SpainBackground: Down syndrome (DS) is a genetic disorder that occurs because of an abnormal division between cells that results in an extra copy of chromosome 21. Some studies show that physical exercise in people with DS increases some cognitive capacities, such as memory, and improves the quality of life. Aim: The main aim of this study was to perform an analysis of the reliability and feasibility of the SAMU-Disability Fitness (DISFIT) battery in adults with DS. Methods: A cross-sectional study with a test−retest design was performed in a maximum interval of 2 weeks in 37 subjects (11 women and 26 men) aged between 21 and 58 years old with DS. Eight field-based fitness tests were proposed to assess the physical fitness (PF) of adults with DS: Body Mass Index (BMI), Waist Circumference (WC), the Timed Up and Go test (TUG), the Deep Trunk Flexibility test (DTF), the Hand Grip test (HG), the Timed Stand Test (TST), the 30-s Sit-Up (SUP) and the 6-Min Walk Test (6MWT). Results: The intra-class correlation coefficient (ICC) in all the tests was good and high (>0.80), except for the 6MWT, whose reliability was fair. Conclusion: The SAMU-DISFIT battery is a reliable and feasible physical fitness battery which has been created with the purpose of establishing tests which measure the four basic components of PF (flexibility, cardiorespiratory fitness, musculoskeletal fitness and motor fitness) in adults with DS.https://www.mdpi.com/1660-4601/16/15/2685Down syndromepsychometryphysical fitnessreliabilityfeasibility
collection DOAJ
language English
format Article
sources DOAJ
author Ruth Cabeza-Ruiz
Francisco Javier Alcántara-Cordero
Isaac Ruiz-Gavilán
Antonio Manuel Sánchez-López
spellingShingle Ruth Cabeza-Ruiz
Francisco Javier Alcántara-Cordero
Isaac Ruiz-Gavilán
Antonio Manuel Sánchez-López
Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
International Journal of Environmental Research and Public Health
Down syndrome
psychometry
physical fitness
reliability
feasibility
author_facet Ruth Cabeza-Ruiz
Francisco Javier Alcántara-Cordero
Isaac Ruiz-Gavilán
Antonio Manuel Sánchez-López
author_sort Ruth Cabeza-Ruiz
title Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
title_short Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
title_full Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
title_fullStr Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
title_full_unstemmed Feasibility and Reliability of a Physical Fitness Test Battery in Individuals with Down Syndrome
title_sort feasibility and reliability of a physical fitness test battery in individuals with down syndrome
publisher MDPI AG
series International Journal of Environmental Research and Public Health
issn 1660-4601
publishDate 2019-07-01
description Background: Down syndrome (DS) is a genetic disorder that occurs because of an abnormal division between cells that results in an extra copy of chromosome 21. Some studies show that physical exercise in people with DS increases some cognitive capacities, such as memory, and improves the quality of life. Aim: The main aim of this study was to perform an analysis of the reliability and feasibility of the SAMU-Disability Fitness (DISFIT) battery in adults with DS. Methods: A cross-sectional study with a test−retest design was performed in a maximum interval of 2 weeks in 37 subjects (11 women and 26 men) aged between 21 and 58 years old with DS. Eight field-based fitness tests were proposed to assess the physical fitness (PF) of adults with DS: Body Mass Index (BMI), Waist Circumference (WC), the Timed Up and Go test (TUG), the Deep Trunk Flexibility test (DTF), the Hand Grip test (HG), the Timed Stand Test (TST), the 30-s Sit-Up (SUP) and the 6-Min Walk Test (6MWT). Results: The intra-class correlation coefficient (ICC) in all the tests was good and high (>0.80), except for the 6MWT, whose reliability was fair. Conclusion: The SAMU-DISFIT battery is a reliable and feasible physical fitness battery which has been created with the purpose of establishing tests which measure the four basic components of PF (flexibility, cardiorespiratory fitness, musculoskeletal fitness and motor fitness) in adults with DS.
topic Down syndrome
psychometry
physical fitness
reliability
feasibility
url https://www.mdpi.com/1660-4601/16/15/2685
work_keys_str_mv AT ruthcabezaruiz feasibilityandreliabilityofaphysicalfitnesstestbatteryinindividualswithdownsyndrome
AT franciscojavieralcantaracordero feasibilityandreliabilityofaphysicalfitnesstestbatteryinindividualswithdownsyndrome
AT isaacruizgavilan feasibilityandreliabilityofaphysicalfitnesstestbatteryinindividualswithdownsyndrome
AT antoniomanuelsanchezlopez feasibilityandreliabilityofaphysicalfitnesstestbatteryinindividualswithdownsyndrome
_version_ 1724974895982444544