Zinc layer anode applied on reinforced concrete structures
The application of zinc layer anode to reinforced concrete structure has been well known for many years. This galvanic cathodic protection system was specified being a corrosion control system for general steel in concrete as well as civil structures. A good way to determine the dimensioning element...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://www.matec-conferences.org/articles/matecconf/pdf/2019/38/matecconf_cs18_03004.pdf |
id |
doaj-2e433e84f6314721b69f76886bb2cf86 |
---|---|
record_format |
Article |
spelling |
doaj-2e433e84f6314721b69f76886bb2cf862021-02-02T04:06:47ZengEDP SciencesMATEC Web of Conferences2261-236X2019-01-012890300410.1051/matecconf/201928903004matecconf_cs18_03004Zinc layer anode applied on reinforced concrete structuresHallopeau Xavier0Moucadeau Eugène1Giorgini Roberto2Lesieutre Olivier3Meillier Arnaud4Annede-Villeau Camille5Freyssinet International & Cie, Technical DepartmentFreyssinet International & Cie, Technical DepartmentCorrpreFreyssinet International & Cie, Technical DepartmentFreyssinet International & Cie, Technical DepartmentFreyssinet International & Cie, Technical DepartmentThe application of zinc layer anode to reinforced concrete structure has been well known for many years. This galvanic cathodic protection system was specified being a corrosion control system for general steel in concrete as well as civil structures. A good way to determine the dimensioning elements of the galvanic protection system, is to carry out a pilot test being monitored in situ, and exposed under on site conditions including local concrete remediation or repair works. This paper presents an analysis of the current distribution and steel polarization data that have been collected from a car park project in the French Alps.https://www.matec-conferences.org/articles/matecconf/pdf/2019/38/matecconf_cs18_03004.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hallopeau Xavier Moucadeau Eugène Giorgini Roberto Lesieutre Olivier Meillier Arnaud Annede-Villeau Camille |
spellingShingle |
Hallopeau Xavier Moucadeau Eugène Giorgini Roberto Lesieutre Olivier Meillier Arnaud Annede-Villeau Camille Zinc layer anode applied on reinforced concrete structures MATEC Web of Conferences |
author_facet |
Hallopeau Xavier Moucadeau Eugène Giorgini Roberto Lesieutre Olivier Meillier Arnaud Annede-Villeau Camille |
author_sort |
Hallopeau Xavier |
title |
Zinc layer anode applied on reinforced concrete structures |
title_short |
Zinc layer anode applied on reinforced concrete structures |
title_full |
Zinc layer anode applied on reinforced concrete structures |
title_fullStr |
Zinc layer anode applied on reinforced concrete structures |
title_full_unstemmed |
Zinc layer anode applied on reinforced concrete structures |
title_sort |
zinc layer anode applied on reinforced concrete structures |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2019-01-01 |
description |
The application of zinc layer anode to reinforced concrete structure has been well known for many years. This galvanic cathodic protection system was specified being a corrosion control system for general steel in concrete as well as civil structures. A good way to determine the dimensioning elements of the galvanic protection system, is to carry out a pilot test being monitored in situ, and exposed under on site conditions including local concrete remediation or repair works. This paper presents an analysis of the current distribution and steel polarization data that have been collected from a car park project in the French Alps. |
url |
https://www.matec-conferences.org/articles/matecconf/pdf/2019/38/matecconf_cs18_03004.pdf |
work_keys_str_mv |
AT hallopeauxavier zinclayeranodeappliedonreinforcedconcretestructures AT moucadeaueugene zinclayeranodeappliedonreinforcedconcretestructures AT giorginiroberto zinclayeranodeappliedonreinforcedconcretestructures AT lesieutreolivier zinclayeranodeappliedonreinforcedconcretestructures AT meillierarnaud zinclayeranodeappliedonreinforcedconcretestructures AT annedevilleaucamille zinclayeranodeappliedonreinforcedconcretestructures |
_version_ |
1724306450982895616 |