Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study

Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic perio...

Full description

Bibliographic Details
Main Authors: Monika Kamboj, Ruchika Arora, Harinder Gupta
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of Indian Society of Periodontology
Subjects:
Online Access:http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=Kamboj
id doaj-2e038a834c3941d792a7846337493369
record_format Article
spelling doaj-2e038a834c3941d792a78463374933692020-11-24T22:34:14ZengWolters Kluwer Medknow PublicationsJournal of Indian Society of Periodontology0972-124X2016-01-0120442342810.4103/0972-124X.184036Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan studyMonika KambojRuchika AroraHarinder GuptaBackground: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim®) or synthetic microcrystalline HA (Osteogen®) bone graft. Clinical parameters including probing depth (PD) and clinical attachment level (CAL) were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties.http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=KambojDenta scanintrabony defectsmicrocrystalline hydroxyapatitenanocrystalline hydroxyapatite
collection DOAJ
language English
format Article
sources DOAJ
author Monika Kamboj
Ruchika Arora
Harinder Gupta
spellingShingle Monika Kamboj
Ruchika Arora
Harinder Gupta
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
Journal of Indian Society of Periodontology
Denta scan
intrabony defects
microcrystalline hydroxyapatite
nanocrystalline hydroxyapatite
author_facet Monika Kamboj
Ruchika Arora
Harinder Gupta
author_sort Monika Kamboj
title Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
title_short Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
title_full Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
title_fullStr Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
title_full_unstemmed Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
title_sort comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (ostim®) and synthetic microcrystalline hydroxyapatite bone graft (osteogen®) in the treatment of human periodontal intrabony defects: a clinical and denta scan study
publisher Wolters Kluwer Medknow Publications
series Journal of Indian Society of Periodontology
issn 0972-124X
publishDate 2016-01-01
description Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim®) or synthetic microcrystalline HA (Osteogen®) bone graft. Clinical parameters including probing depth (PD) and clinical attachment level (CAL) were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties.
topic Denta scan
intrabony defects
microcrystalline hydroxyapatite
nanocrystalline hydroxyapatite
url http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=Kamboj
work_keys_str_mv AT monikakamboj comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy
AT ruchikaarora comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy
AT harindergupta comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy
_version_ 1725728747513970688