Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study
Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic perio...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2016-01-01
|
Series: | Journal of Indian Society of Periodontology |
Subjects: | |
Online Access: | http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=Kamboj |
id |
doaj-2e038a834c3941d792a7846337493369 |
---|---|
record_format |
Article |
spelling |
doaj-2e038a834c3941d792a78463374933692020-11-24T22:34:14ZengWolters Kluwer Medknow PublicationsJournal of Indian Society of Periodontology0972-124X2016-01-0120442342810.4103/0972-124X.184036Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan studyMonika KambojRuchika AroraHarinder GuptaBackground: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim®) or synthetic microcrystalline HA (Osteogen®) bone graft. Clinical parameters including probing depth (PD) and clinical attachment level (CAL) were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties.http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=KambojDenta scanintrabony defectsmicrocrystalline hydroxyapatitenanocrystalline hydroxyapatite |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Monika Kamboj Ruchika Arora Harinder Gupta |
spellingShingle |
Monika Kamboj Ruchika Arora Harinder Gupta Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study Journal of Indian Society of Periodontology Denta scan intrabony defects microcrystalline hydroxyapatite nanocrystalline hydroxyapatite |
author_facet |
Monika Kamboj Ruchika Arora Harinder Gupta |
author_sort |
Monika Kamboj |
title |
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study |
title_short |
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study |
title_full |
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study |
title_fullStr |
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study |
title_full_unstemmed |
Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study |
title_sort |
comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (ostim®) and synthetic microcrystalline hydroxyapatite bone graft (osteogen®) in the treatment of human periodontal intrabony defects: a clinical and denta scan study |
publisher |
Wolters Kluwer Medknow Publications |
series |
Journal of Indian Society of Periodontology |
issn |
0972-124X |
publishDate |
2016-01-01 |
description |
Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim®) or synthetic microcrystalline HA (Osteogen®) bone graft. Clinical parameters including probing depth (PD) and clinical attachment level (CAL) were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties. |
topic |
Denta scan intrabony defects microcrystalline hydroxyapatite nanocrystalline hydroxyapatite |
url |
http://www.jisponline.com/article.asp?issn=0972-124X;year=2016;volume=20;issue=4;spage=423;epage=428;aulast=Kamboj |
work_keys_str_mv |
AT monikakamboj comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy AT ruchikaarora comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy AT harindergupta comparativeevaluationoftheefficacyofsyntheticnanocrystallinehydroxyapatitebonegraftostimandsyntheticmicrocrystallinehydroxyapatitebonegraftosteogeninthetreatmentofhumanperiodontalintrabonydefectsaclinicalanddentascanstudy |
_version_ |
1725728747513970688 |