The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns

ABSTRACT Purpose: To analyze intraocular pressure (IOP) and central corneal thickness (CCT) in newborns during the first 12 h of life. Methods: Forty-three newborns born by vaginal delivery (VD) and 30 newborns born by cesarean section (CS) were evaluated. IOP and CCT were measured using Tono-Pen...

Full description

Bibliographic Details
Main Authors: Zeynep Gursel Ozkurt, Selahattin Balsak, Berrin Balsak, Hande Guclu, Muhammed Sahın, Harun Yuksel, Fatih M. Turkcu
Format: Article
Language:English
Published: Conselho Brasileiro de Oftalmologia 2016-04-01
Series:Arquivos Brasileiros de Oftalmologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000200092&lng=en&tlng=en
id doaj-2e005f785aa446f187ad53a140e70fad
record_format Article
spelling doaj-2e005f785aa446f187ad53a140e70fad2020-11-24T21:41:20ZengConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia1678-29252016-04-01792929510.5935/0004-2749.20160028S0004-27492016000200092The effects of delivery type and gender on intraocular pressure and central corneal thickness in newbornsZeynep Gursel OzkurtSelahattin BalsakBerrin BalsakHande GucluMuhammed SahınHarun YukselFatih M. TurkcuABSTRACT Purpose: To analyze intraocular pressure (IOP) and central corneal thickness (CCT) in newborns during the first 12 h of life. Methods: Forty-three newborns born by vaginal delivery (VD) and 30 newborns born by cesarean section (CS) were evaluated. IOP and CCT were measured using Tono-Pen and handheld pachymeter, respectively, at both the 5th minute after delivery and at the 12th h of life. Results: The mean IOP for the VD group was significantly higher than that of the CS group at both the 5th minute and 12th h (p =0.042 and p =0.018, respectively). In both groups, the IOP decreased by the 12th h, but the decrease was only significant for the CS group (p =0.020). The decrease in CCT over the 12 h was significant for both groups (p <0.001). In the VD and CS groups, the IOP values of the males were significantly higher than those of the females at the fifth minute only (p =0.024 and p =0.043, respectively). No other values were significantly different between the genders. Conclusions: Newborn IOP is affected by the mode of delivery and gender. A higher IOP was found in vaginally delivered newborns than in CS newborns for at least 12 h postpartum. CCT showed a significant decline within 12 h. Male newborns have significantly higher IOP values in the first minutes of life.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000200092&lng=en&tlng=enCesáreaParto obstétricoPressão intraocularCórnea/anatomia & histologiaRecém-nascido
collection DOAJ
language English
format Article
sources DOAJ
author Zeynep Gursel Ozkurt
Selahattin Balsak
Berrin Balsak
Hande Guclu
Muhammed Sahın
Harun Yuksel
Fatih M. Turkcu
spellingShingle Zeynep Gursel Ozkurt
Selahattin Balsak
Berrin Balsak
Hande Guclu
Muhammed Sahın
Harun Yuksel
Fatih M. Turkcu
The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
Arquivos Brasileiros de Oftalmologia
Cesárea
Parto obstétrico
Pressão intraocular
Córnea/anatomia & histologia
Recém-nascido
author_facet Zeynep Gursel Ozkurt
Selahattin Balsak
Berrin Balsak
Hande Guclu
Muhammed Sahın
Harun Yuksel
Fatih M. Turkcu
author_sort Zeynep Gursel Ozkurt
title The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
title_short The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
title_full The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
title_fullStr The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
title_full_unstemmed The effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
title_sort effects of delivery type and gender on intraocular pressure and central corneal thickness in newborns
publisher Conselho Brasileiro de Oftalmologia
series Arquivos Brasileiros de Oftalmologia
issn 1678-2925
publishDate 2016-04-01
description ABSTRACT Purpose: To analyze intraocular pressure (IOP) and central corneal thickness (CCT) in newborns during the first 12 h of life. Methods: Forty-three newborns born by vaginal delivery (VD) and 30 newborns born by cesarean section (CS) were evaluated. IOP and CCT were measured using Tono-Pen and handheld pachymeter, respectively, at both the 5th minute after delivery and at the 12th h of life. Results: The mean IOP for the VD group was significantly higher than that of the CS group at both the 5th minute and 12th h (p =0.042 and p =0.018, respectively). In both groups, the IOP decreased by the 12th h, but the decrease was only significant for the CS group (p =0.020). The decrease in CCT over the 12 h was significant for both groups (p <0.001). In the VD and CS groups, the IOP values of the males were significantly higher than those of the females at the fifth minute only (p =0.024 and p =0.043, respectively). No other values were significantly different between the genders. Conclusions: Newborn IOP is affected by the mode of delivery and gender. A higher IOP was found in vaginally delivered newborns than in CS newborns for at least 12 h postpartum. CCT showed a significant decline within 12 h. Male newborns have significantly higher IOP values in the first minutes of life.
topic Cesárea
Parto obstétrico
Pressão intraocular
Córnea/anatomia & histologia
Recém-nascido
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000200092&lng=en&tlng=en
work_keys_str_mv AT zeynepgurselozkurt theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT selahattinbalsak theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT berrinbalsak theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT handeguclu theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT muhammedsahın theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT harunyuksel theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT fatihmturkcu theeffectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT zeynepgurselozkurt effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT selahattinbalsak effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT berrinbalsak effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT handeguclu effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT muhammedsahın effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT harunyuksel effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
AT fatihmturkcu effectsofdeliverytypeandgenderonintraocularpressureandcentralcornealthicknessinnewborns
_version_ 1725922644207861760