The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system

Each pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small-molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject...

Full description

Bibliographic Details
Main Authors: Anna Maria Lempart, Edyta Anna Kudlek, Mariusz Dudziak, Artur Szyguła
Format: Article
Language:Polish
Published: Polish Society of Ecological Engineering (PTIE) 2018-04-01
Series:Inżynieria Ekologiczna
Subjects:
Online Access:http://www.journalssystem.com/ie/Ocena-wplywu-systemu-cyrkulacji-na-poziom-stezen-mikrozanieczyszczen-w-ukladzie-oczyszczania,86051,0,2.html
id doaj-2da5ba77a28a4bfea779ae0caaf45d28
record_format Article
spelling doaj-2da5ba77a28a4bfea779ae0caaf45d282020-11-24T23:13:55ZpolPolish Society of Ecological Engineering (PTIE)Inżynieria Ekologiczna2081-139X2392-06292018-04-01192233110.12912/23920629/8605186051The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment systemAnna Maria Lempart0Edyta Anna Kudlek1Mariusz Dudziak2Artur Szyguła3Politechnika Śląska w Gliwicach, Wydział Inżynierii Środowiska i Energetyki, Instytut Inżynierii Wody i Ścieków, ul. Konarskiego 18, 44-100 GliwiceSilesian University of Technology, Institute of Water and Wastewater EngineeringSilesian University of Technology, Institute of Water and Wastewater EngineeringSilesian University of Technology, Institute of Water and Wastewater EngineeringEach pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small-molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject this argument. As part of preliminary tests, the content of organic and inorganic substances in swimming pool water was analyzed based on general indicators such as TOC, UV 254 absorbance and conductivity. In the main stage of the research, pool water samples collected from four different points of the swimming pool installation were subjected to chromatographic analysis to determine the small-molecule micropollutants. The tap water used to fill the basin and regular replenishment of volume losses was also tested. This study was intended to exclude the tap water as a potential source of contamination in the pool water. Preliminary studies have shown almost a two-fold increase in the total organic carbon content and absorbance UV 254 at the turn of six months, which undoubtedly indicates the accumulation of organic pollutants in pool water circulation systems. It was not observed in the case of inorganic compounds. As a result of the chromatographic analyzes of the pool water, the content of pharmaceuticals and personal care product was determined. It was found that the compensation tank is the place of the highest accumulation of the tested pharmaceuticals in the pool water treatment system , while the cosmetics component accumulated in the pool basin to the greatest degree. It was affected by the duration of the filter cycle.http://www.journalssystem.com/ie/Ocena-wplywu-systemu-cyrkulacji-na-poziom-stezen-mikrozanieczyszczen-w-ukladzie-oczyszczania,86051,0,2.htmlpool water treatment systemswater circulationmicropollutantsPPCPs
collection DOAJ
language Polish
format Article
sources DOAJ
author Anna Maria Lempart
Edyta Anna Kudlek
Mariusz Dudziak
Artur Szyguła
spellingShingle Anna Maria Lempart
Edyta Anna Kudlek
Mariusz Dudziak
Artur Szyguła
The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
Inżynieria Ekologiczna
pool water treatment systems
water circulation
micropollutants
PPCPs
author_facet Anna Maria Lempart
Edyta Anna Kudlek
Mariusz Dudziak
Artur Szyguła
author_sort Anna Maria Lempart
title The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
title_short The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
title_full The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
title_fullStr The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
title_full_unstemmed The impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
title_sort impact of the circulation system on the concentration level of micropollutants in the swimming pool water treatment system
publisher Polish Society of Ecological Engineering (PTIE)
series Inżynieria Ekologiczna
issn 2081-139X
2392-0629
publishDate 2018-04-01
description Each pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small-molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject this argument. As part of preliminary tests, the content of organic and inorganic substances in swimming pool water was analyzed based on general indicators such as TOC, UV 254 absorbance and conductivity. In the main stage of the research, pool water samples collected from four different points of the swimming pool installation were subjected to chromatographic analysis to determine the small-molecule micropollutants. The tap water used to fill the basin and regular replenishment of volume losses was also tested. This study was intended to exclude the tap water as a potential source of contamination in the pool water. Preliminary studies have shown almost a two-fold increase in the total organic carbon content and absorbance UV 254 at the turn of six months, which undoubtedly indicates the accumulation of organic pollutants in pool water circulation systems. It was not observed in the case of inorganic compounds. As a result of the chromatographic analyzes of the pool water, the content of pharmaceuticals and personal care product was determined. It was found that the compensation tank is the place of the highest accumulation of the tested pharmaceuticals in the pool water treatment system , while the cosmetics component accumulated in the pool basin to the greatest degree. It was affected by the duration of the filter cycle.
topic pool water treatment systems
water circulation
micropollutants
PPCPs
url http://www.journalssystem.com/ie/Ocena-wplywu-systemu-cyrkulacji-na-poziom-stezen-mikrozanieczyszczen-w-ukladzie-oczyszczania,86051,0,2.html
work_keys_str_mv AT annamarialempart theimpactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT edytaannakudlek theimpactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT mariuszdudziak theimpactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT arturszyguła theimpactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT annamarialempart impactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT edytaannakudlek impactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT mariuszdudziak impactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
AT arturszyguła impactofthecirculationsystemontheconcentrationlevelofmicropollutantsintheswimmingpoolwatertreatmentsystem
_version_ 1725596100515069952