High-throughput retrotransposon-based fluorescent markers: improved information content and allele discrimination

<p>Abstract</p> <p>Background</p> <p>Dense genetic maps, together with the efficiency and accuracy of their construction, are integral to genetic studies and marker assisted selection for plant breeding. High-throughput multiplex markers that are robust and reproducible...

Full description

Bibliographic Details
Main Authors: Baker David, Lipscombe James, Moreau Carol, Knox Maggie, Ellis Noel
Format: Article
Language:English
Published: BMC 2009-07-01
Series:Plant Methods
Online Access:http://www.plantmethods.com/content/5/1/10
Description
Summary:<p>Abstract</p> <p>Background</p> <p>Dense genetic maps, together with the efficiency and accuracy of their construction, are integral to genetic studies and marker assisted selection for plant breeding. High-throughput multiplex markers that are robust and reproducible can contribute to both efficiency and accuracy. Multiplex markers are often dominant and so have low information content, this coupled with the pressure to find alternatives to radio-labelling, has led us to adapt the SSAP (sequence specific amplified polymorphism) marker method from a <sup>33</sup>P labelling procedure to fluorescently tagged markers analysed from an automated ABI 3730 <it>xl </it>platform. This method is illustrated for multiplexed SSAP markers based on retrotransposon insertions of pea and is applicable for the rapid and efficient generation of markers from genomes where repetitive element sequence information is available for primer design. We cross-reference SSAP markers previously generated using the <sup>33</sup>P manual PAGE system to fluorescent peaks, and use these high-throughput fluorescent SSAP markers for further genetic studies in <it>Pisum</it>.</p> <p>Results</p> <p>The optimal conditions for the fluorescent-labelling method used a triplex set of primers in the PCR. These included a fluorescently labelled specific primer together with its unlabelled counterpart, plus an adapter-based primer with two bases of selection on the 3' end. The introduction of the unlabelled specific primer helped to optimise the fluorescent signal across the range of fragment sizes expected, and eliminated the need for extensive dilutions of PCR amplicons. The software (GeneMarker Version 1.6) used for the high-throughput data analysis provided an assessment of amplicon size in nucleotides, peak areas and fluorescence intensity in a table format, so providing additional information content for each marker. The method has been tested in a small-scale study with 12 pea accessions resulting in 467 polymorphic fluorescent SSAP markers of which 260 were identified as having been mapped previously using the radio-labelling technique. Heterozygous individuals from pea cultivar crosses were identifiable after peak area data analysis using the fluorescent SSAP method.</p> <p>Conclusion</p> <p>As well as developing a rapid, and high-throughput marker method for genetic studies, the fluorescent SSAP system improved the accuracy of amplicon scoring, increased the available marker number, improved allele discrimination, and was sensitive enough to identify heterozygous loci in F<sub>1 </sub>and F<sub>2 </sub>progeny, indicating the potential to develop high-throughput codominant SSAPs.</p>
ISSN:1746-4811