Study on Insulation Breakdown Characteristics of Printed Circuit Board under Continuous Square Impulse Voltage

The widely distributed interconnects in printed circuit boards (PCBs) easily couple with high voltage under the action of electromagnetic pulses, which leads to insulation failure. In this study, the dielectric breakdown characteristics of four typical PCBs are studied under continuous square impuls...

Full description

Bibliographic Details
Main Authors: Quan Zhou, Mingqian Wen, Taotao Xiong, Tianyan Jiang, Ming Zhou, Xi Ouyang, Lai Xing
Format: Article
Language:English
Published: MDPI AG 2018-10-01
Series:Energies
Subjects:
PCB
SEM
Online Access:https://www.mdpi.com/1996-1073/11/11/2908
Description
Summary:The widely distributed interconnects in printed circuit boards (PCBs) easily couple with high voltage under the action of electromagnetic pulses, which leads to insulation failure. In this study, the dielectric breakdown characteristics of four typical PCBs are studied under continuous square impulse voltage conditions. First, the electric field distribution in the four electrode models is simulated with the ANSYS software (ANSYS Maxwell 17.0). Electric field simulation results show the weak area of electric field distribution. On this basis, the possible breakdown patterns of PCB are analyzed. Second, the influence of factors, such as temperature, pulse duty ratio, interconnect insulation distance, and air pressure, on PCB breakdown voltage is studied through a breakdown test on the PCBs. Results show that the discharge between the single-layer electrodes of the PCBs is surface discharge, and the breakdown is that of a “gas⁻solid composite medium„. Meanwhile, the breakdown of a double-layer PCB is solid breakdown. Finally, scanning electron microscopy (SEM) produced by Tescan (Brno, Czech Republic) is performed to study the carbonization channel after PCB breakdown. SEM results reveal that the PCB carbonization channel is influenced by temperature and pressure in varying degrees.
ISSN:1996-1073